Search results

Jump to navigation Jump to search

Page title matches

  • ==Nickel Normalization== Talk about Nickel reaction, give example of Nickel rates for 511 and 1377 keV lines. Run condition for examples below.
    10 KB (1,145 words) - 03:40, 3 May 2017
  • ...the main issues that I will address in this section is whether or not the nickel foils on the front and back of the target have the same activity. The files
    330 bytes (58 words) - 21:01, 6 September 2017
  • In finding the initial activity of the front nickel foil of this sample, look at the window from [1356,1368]. The method I used Note that this spectrum is weighted by the inverse of the mass of the nickel. So the natural log of the activity is what we want to put in the .dat file
    2 KB (342 words) - 14:48, 18 October 2017
  • ...e histograms made were weighted by the time of the run and the mass of the nickel foil. Below is a table for the front nickel foil:
    11 KB (1,160 words) - 19:42, 9 November 2017
  • The activity of Nickel foils from the front and rear of the sample container were compared. Below ...cally the same, but the ratio between the activities of the front and rear nickel foil is 0.80 +/- 0.02
    5 KB (560 words) - 20:21, 21 February 2018
  • ...a table with thin windows, original windows, and expanded windows for the nickel on sample 170063. The thin window method can be found at [[LB Thesis Thin W By exponentiating the intercept, we can find the activity of the nickel foil at the time of the first measurement, which is
    5 KB (495 words) - 22:02, 6 December 2017
  • [[File:170063 Nickel WideGauss HLPlot.png|200px]]
    2 KB (160 words) - 14:10, 26 October 2017
  • [[File:170063 Nickel WideGauss HLPlot.png|200px]]
    2 KB (211 words) - 15:39, 26 October 2017

Page text matches

  • ...n front of and behind the Au+Sand, the blank crucible, and the gold foil. Nickel foils were also place in front of and behind the crucible with the Barium O Naturally occurring Isotopes of Nickel are
    2 KB (325 words) - 21:59, 16 November 2014
  • ...Schottky contact. An ohmic contact was formed by annealing from 100 nm of nickel deposited on the substrate and annealed. The devices were characterized thr
    1 KB (203 words) - 20:58, 14 March 2012
  • ...the main issues that I will address in this section is whether or not the nickel foils on the front and back of the target have the same activity. The files
    330 bytes (58 words) - 21:01, 6 September 2017
  • ==Nickel Normalization== Talk about Nickel reaction, give example of Nickel rates for 511 and 1377 keV lines. Run condition for examples below.
    10 KB (1,145 words) - 03:40, 3 May 2017
  • =Relative to Nickel= ==Nickel counts==
    4 KB (575 words) - 17:40, 15 May 2013
  • ...suring the mass of the sample, then putting a front nickel foil and a back nickel foil around the selenium pellets and wrapping the whole target in Kapton ta
    1 KB (210 words) - 17:26, 10 February 2017
  • ...o an aluminum/tungsten radiator. After that the particles will encounter a nickel foil followed by an aluminum sheet and finally a selenium pellet that is -0 Nickel Foil: 6cm in x, 2cm in y
    3 KB (632 words) - 17:06, 26 February 2018
  • In finding the initial activity of the front nickel foil of this sample, look at the window from [1356,1368]. The method I used Note that this spectrum is weighted by the inverse of the mass of the nickel. So the natural log of the activity is what we want to put in the .dat file
    2 KB (342 words) - 14:48, 18 October 2017
  • Jack Profile from Nickel foils 1m from converter There is no 583 keV peak for the Nickel foil.
    2 KB (237 words) - 23:07, 14 June 2018
  • So lets try to correct these ratios using Nickel ...tio is lower than its original value (0.62), which makes sense because the nickel would not die off as much in the beam. The 10% and 1% values should not nee
    4 KB (717 words) - 22:35, 25 July 2018
  • ...m cylinder that was to be irradiated. The target components consisted of a nickel foil on the front of the cylinder with 2 pure selenium pellets under the fo Nickel Foil: 0.2783g
    6 KB (839 words) - 17:54, 9 November 2017
  • ...|| Front Inner Nickel Foil (g) || Rear Inner Nickel Foil (g) || Rear Outer Nickel Foil (g)
    5 KB (694 words) - 21:07, 30 May 2018
  • ==Nickel Normalization== [[LB PAA Nickel Investigation]]
    5 KB (619 words) - 22:10, 17 May 2019
  • ...e histograms made were weighted by the time of the run and the mass of the nickel foil. Below is a table for the front nickel foil:
    11 KB (1,160 words) - 19:42, 9 November 2017
  • ||5/4/2017 || U5 Nickel || U5_Ni_5_4_17 || 15:07:47 || ||65139.738 || @ detector face (b) ||5/5/2017 || U5 Nickel || U5_Ni_5_5_17 || 11:17:37 ||13:15 || || @ detector face (b)
    9 KB (628 words) - 17:41, 22 May 2018
  • =Nickel Information= Front Nickel Foil Table:
    6 KB (529 words) - 22:52, 23 March 2018
  • [[File:170063 Nickel WideGauss HLPlot.png|200px]]
    2 KB (160 words) - 14:10, 26 October 2017
  • [[File:170063 Nickel WideGauss HLPlot.png|200px]]
    2 KB (211 words) - 15:39, 26 October 2017
  • The activity of Nickel foils from the front and rear of the sample container were compared. Below ...cally the same, but the ratio between the activities of the front and rear nickel foil is 0.80 +/- 0.02
    5 KB (560 words) - 20:21, 21 February 2018
  • ...action of electron waves using 54 eV electrons impinging a crystal made of nickel.
    4 KB (571 words) - 15:59, 30 September 2009
  • ...a table with thin windows, original windows, and expanded windows for the nickel on sample 170063. The thin window method can be found at [[LB Thesis Thin W By exponentiating the intercept, we can find the activity of the nickel foil at the time of the first measurement, which is
    5 KB (495 words) - 22:02, 6 December 2017
  • ...l normalization, one can predict how much Se-79 will be made. See [[LB PAA Nickel Investigation]] for more information. [[LB PAA Nickel Investigation]]
    8 KB (1,260 words) - 17:22, 12 March 2018
  • |+General Target configurations, Selenium pellets are sandwiched between two Nickel foils
    6 KB (585 words) - 20:10, 8 March 2016
  • Front Outer Nickel Foil: 3.4274g =Nickel Foil Information=
    15 KB (1,439 words) - 01:19, 29 March 2018
  • =Nickel Information= [[LB 170048 Nickel Foil Consistency Check]]
    8 KB (757 words) - 22:31, 2 May 2018
  • ==Nickel Normaization==
    2 KB (267 words) - 23:09, 14 June 2018
  • I borrowed a USB DVD drive from Ben Nickel to install CENTOS from a live DVD
    4 KB (712 words) - 18:46, 13 July 2017
  • ...is a table of the Se-75 (120d) corrected measurements as well as the front nickel foils and the Mn-54 data for each measurement. Note the Mn-54 analysis was ...io was taken using Ni-57 as a reference material. This was the front inner Nickel foil
    13 KB (1,914 words) - 16:40, 6 August 2018
  • Nickel sample ID = 190028-03
    5 KB (723 words) - 20:26, 23 May 2019
  • ...o check the ratio of the nickel with the selenium mixture. The rate of the nickel foil was <math> 1.127931 \times 10^6 \pm 7.258 \times 10^3 Hz </math>
    40 KB (5,416 words) - 19:19, 11 January 2018
  • | bgcolor="#ff8700" | [[Nickel|Ni]]<br/>135
    8 KB (924 words) - 18:17, 26 September 2018
  • =Nickel Information=
    8 KB (704 words) - 21:35, 25 March 2018
  • ...\atop 13} Al_{15} + p</math> , half life is 2.2 min, Activity ratio w.r.t. Nickel after 1 hour of irradiation = 3.6, Egamma = 1779 keV ...\atop 13} Al_{16} + p</math> , half life is 6.6 min, Activity ratio w.r.t. Nickel = 1.5, Egamma = 1274 keV
    21 KB (3,142 words) - 18:14, 16 March 2017
  • loss of creep ductility in nickel-based alloys are especially desirable. Materials that
    7 KB (945 words) - 17:15, 10 December 2018
  • ...nt_Ash_Se_Mix_SplitRun_Run3.mpa ||11:25:12 || 13:00|| ||41cm (Det A) || || nickel introduced to detector B Inv # 170068-003 at 4660s Pos C ? Is the Activity of the front and back nickel targets the same?
    29 KB (3,178 words) - 22:08, 16 May 2018
  • Using nickel target you can take ratios to try and approximate <math>\Phi</math> === Nickel normalization===
    74 KB (9,263 words) - 17:37, 5 May 2015
  • =Nickel normalization foils=
    24 KB (3,117 words) - 17:22, 21 October 2016
  • Nickel Foil: 0.2783g
    13 KB (2,109 words) - 19:25, 10 January 2018
  • ...o containing much larger individual crystals of olivine, pyroxene and iron/nickel sulfides. All analyses suggest that small and large Wild 2 particles are co
    14 KB (2,119 words) - 21:14, 3 April 2014
  • |Nickel-cadmium|| 1.25 ||rechargeable flashlight battery
    26 KB (4,334 words) - 19:14, 20 January 2015
  • One can use Nickel as a normalization target to remove the photon flux <math>(\phi)</math> fro
    11 KB (1,317 words) - 16:57, 23 February 2018
  • |Nickel-63|| || Used in light sensors in cameras and plasma display, also electroni
    21 KB (3,007 words) - 21:42, 19 April 2013
  • ...to a polyethylene block. An additional gold foil was inserted between the nickel foil and polyethylene. Table YYY describes the dimensions of the foils used
    65 KB (9,336 words) - 19:43, 5 December 2016
  • ...nverts into a proton and emits an electron (charge conservation) leaving a Nickel nucleus.
    34 KB (5,274 words) - 21:10, 9 January 2012
  • \caption{Neutron knockout cross section for selenium isotopes and nickel used in this work} ...of time, the decay constant, and thus the half life can be found. A sample nickel spectrum which has been fitted with an exponential function is shown in Fig
    108 KB (16,347 words) - 20:56, 2 October 2018
  • ...-004, post amp at 20, min sec, rate is about 0.21 Hz, ended early to run nickel
    92 KB (10,756 words) - 18:56, 12 November 2014