Difference between revisions of "Positrons"
Jump to navigation
Jump to search
Line 73: | Line 73: | ||
− | == 4-6way cross for 45 degree line == | + | ==1. 4-6way cross for 45 degree line == |
5 cross for the 45 degree beam line flag. | 5 cross for the 45 degree beam line flag. | ||
Line 85: | Line 85: | ||
|} | |} | ||
− | == 5-6 way cross for 90 degree line == | + | ==2. 5-6 way cross for 90 degree line == |
We have one 3-way cross for this. But it is preferred to use 5-6 way cross, since we attach NaI detectors to it like we did in JLab PEPPo. | We have one 3-way cross for this. But it is preferred to use 5-6 way cross, since we attach NaI detectors to it like we did in JLab PEPPo. | ||
Line 99: | Line 99: | ||
|} | |} | ||
− | == Double side Flange for Jlab Flag 3 == | + | ==3. Double side Flange for Jlab Flag 3 == |
I need to check if we have it or not. | I need to check if we have it or not. | ||
− | == | + | ==4. Flanges for 90 degree beam line == |
− | |||
{| border="1" |cellpadding="20" cellspacing="0 | {| border="1" |cellpadding="20" cellspacing="0 | ||
Line 115: | Line 114: | ||
|} | |} | ||
− | == | + | ==5. Ion pump parts == |
Ion pump parts | Ion pump parts | ||
Line 127: | Line 126: | ||
|} | |} | ||
− | == Target chamber parts == | + | ==6. Target chamber parts == |
Target chamber parts (HV = 10^{-8} Torr) | Target chamber parts (HV = 10^{-8} Torr) |
Revision as of 19:33, 8 March 2012
Proposals
Collaboration
Work
Designs
- IAC positron beamline
- OptiM32_HRRL_PositronDesign
- Beamline design (G. Stancari)
- Beamline design (Y. Kim)
- Beamline_Drawing_2011_J.Ellis
- HRRL_Positron_Rotating_W_Target
- 90 degree beamline extension
HRRL beam Line installation
Experiments
- CHIPS_Run_Feb-2008
- CHIPS_Run_May-2008
- HRRL radiation tests
- Emittance Test
- HRRL OTR Test Feb 16th 2011
- HRRL OTR Test Mar 3rd 2011
- HRRL_Emittance_Measurements_March14-18-2011
- Emittance Measurement with Optical transition Radiation (OTR)
- PePPO_NaI_PositronDetector_4_JLab
- IAC_NaI_Detectors
- Coincidence_with_NaI_Detectors
- PePPO_2011Run
- PePPO_2012Run
- PePPO_02222012
Simulations
Equipment
References
- JLab Positron Wiki
- JPOS09
- Positron_References
- Python
- File:SadiqTalkPePPO 4-26-2011.pdf
- e+ Gun Beam Line Construction
Neutron production
MDC Parts list
1. 4-6way cross for 45 degree line
5 cross for the 45 degree beam line flag.
Parts | Quantity | Link |
5-way cross | 1 | 5-way cross |
2. 5-6 way cross for 90 degree line
We have one 3-way cross for this. But it is preferred to use 5-6 way cross, since we attach NaI detectors to it like we did in JLab PEPPo.
Parts | Quantity | Link |
5-way cross | either one 6-way or 5-way cross. | 5-way cross |
6-way cross | either one 6-way or 5-way cross. | 6-way cross |
3. Double side Flange for Jlab Flag 3
I need to check if we have it or not.
4. Flanges for 90 degree beam line
Parts | Quantity | Link |
Flng, 4.5"x2.5"Rotatable | 2 | Flange 450-250 |
5. Ion pump parts
Ion pump parts
Parts | Parts Label | Quantity | Link |
Reduced 3-way Cross (T) | ReducingTee, 4.5"x2.75" | 1 | Reduced T |
6. Target chamber parts
Target chamber parts (HV = 10^{-8} Torr)
a.) 10- pin wiring feedthrough
http://www.mdcvacuum.com/displayproductcontent.aspx?d=MDC&p=i.1.1.2.1
b.) 4 flexible hoses for cooling lines (at least nitrogen gas hopefully liquid nitrogen)
http://www.mdcvacuum.com/displayproductcontent.aspx?d=MDC&p=m.6.2.4.1
c.) IR optical window for target temperature measurement
http://www.mdcvacuum.com/displayproductcontent.aspx?d=MDC&p=i.7.1.1.1