Difference between revisions of "Positrons"

From New IAC Wiki
Jump to navigation Jump to search
Line 75: Line 75:
 
== 4-6way cross for 45 degree line ==
 
== 4-6way cross for 45 degree line ==
  
5 cross for the 45 degree beam line flag
+
5 cross for the 45 degree beam line flag.
  
http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=406005
+
{| border="1"  |cellpadding="20" cellspacing="0
 
+
|-
Quantity needed: 1
+
| Parts        ||  Parts Label || Quantity || Link
 +
|-
 +
| 5-way cross  ||              ||    1    || http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=406005
 +
|-
 +
|}
  
 
== 5-6 way cross for 90 degree line ==
 
== 5-6 way cross for 90 degree line ==
Line 85: Line 89:
 
We have one 3-way cross for this. But it is preferred to use 5-6 way cross, since we attach NaI detectors to it like we did in JLab PEPPo.
 
We have one 3-way cross for this. But it is preferred to use 5-6 way cross, since we attach NaI detectors to it like we did in JLab PEPPo.
  
5-way cross for the 90 degree beam line Annihilation Target flag.
+
{| border="1"  |cellpadding="20" cellspacing="0
 
+
|-
http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=406005
+
| Parts        || Parts Label || Quantity || Link
 
+
|-
6-way cross for the 90 degree beam line Annihilation Target flag.
+
|  5-way cross ||            ||    either 1 6-way or 5-way cross.     || http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=406005
 
+
|-
http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=407005
+
6-way cross ||            ||    either 1 6-way or 5-way cross.     || http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=407005
 
+
|-
 
+
|}
Quantity needed: either 1 6-way or 5-way cross.
 
  
 
== Double side Flange for Jlab Flag 3 ==
 
== Double side Flange for Jlab Flag 3 ==
Line 115: Line 118:
  
 
Quantity needed: 2
 
Quantity needed: 2
 +
 +
{| border="1"  |cellpadding="20" cellspacing="0
 +
|-
 +
| Parts ||  Parts Label || Quantity || Link
 +
|-
 +
|  ||  || 1 ||
 +
|-
 +
|}
  
 
== 3 Ion pump parts ==
 
== 3 Ion pump parts ==
Line 127: Line 138:
 
|-
 
|-
 
|}
 
|}
 
I found a 3-way cross on the a chamber left on a desk in the beam lab. There also 2 adaptors that adapt to 450 Flanges. We might be able to use it, I will check with Kevin.
 
  
 
== Target chamber parts ==
 
== Target chamber parts ==

Revision as of 19:27, 8 March 2012

Proposals

Collaboration

Work

Designs

HRRL beam Line installation

Experiments

Simulations

Equipment

References

Neutron production

File:Huang NIMB229 2005.pdf


MDC Parts list

4-6way cross for 45 degree line

5 cross for the 45 degree beam line flag.

Parts Parts Label Quantity Link
5-way cross 1 http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=406005

5-6 way cross for 90 degree line

We have one 3-way cross for this. But it is preferred to use 5-6 way cross, since we attach NaI detectors to it like we did in JLab PEPPo.

Parts Parts Label Quantity Link
5-way cross either 1 6-way or 5-way cross. http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=406005
6-way cross either 1 6-way or 5-way cross. http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=407005

Double side Flange for Jlab Flag 3

I need to check if we have it or not.

1. Flanges for 90 degree beam line

450-250

100021 - Flng, 4.5"x2.5"Rotatable

  1. MODEL REFERENCE: REF# F450250R
  1. PART NUMBER: 100021
  1. PART NAME: Flng, 4.5"x2.5"Rotatable

http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=100021

Quantity needed: 2

Parts Parts Label Quantity Link
1

3 Ion pump parts

Ion pump parts

Parts Parts Label Quantity Link
Reduced 3-way Cross (T) ReducingTee, 4.5"x2.75" 1 http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=404048

Target chamber parts

Target chamber parts (HV = 10^{-8} Torr)

a.) 10- pin wiring feedthrough

http://www.mdcvacuum.com/displayproductcontent.aspx?d=MDC&p=i.1.1.2.1

b.) 4 flexible hoses for cooling lines (at least nitrogen gas hopefully liquid nitrogen)

http://www.mdcvacuum.com/displayproductcontent.aspx?d=MDC&p=m.6.2.4.1

c.) IR optical window for target temperature measurement

http://www.mdcvacuum.com/displayproductcontent.aspx?d=MDC&p=i.7.1.1.1


User_talk:foretony


User:Setisadi