R3833 Efficiency1

From New IAC Wiki
Jump to navigation Jump to search

My first attempt at an efficiency measurement compares wire hits when you require that the first (wire 1) and last (wire 6) wires in a single super layer are hit.

First I looked at which wires were hit when I require that there is a hit on wire 1 and wire 2.

HV was G:F:S = 536:-750:1500 Volts


R3833 1WireHitsRow-vs-Column.png

Most of the hits are in row 9.


If I histogram all wire hits requiring a hit in both wire 1, wire 6 and row 9 I see the following

R3833 1WireHitsCol9.png

Now I divide by the number of hits seen by both wire 1 and wire 6

R3833 1WireHitsCol9N.png


If I now require that Wires 1-3 and 5-6 from column 9 have hits and then ask how many hits did wire 4 have I get an efficiency of about 98%.

R3833 1WireHitsCol9n5wires.png


Using run 3834, the efficiency increase to 99% when the discriminator is increased from -30 mV to -60 mV

R3834 1WireHitsCol9n5wires.png


CLAS12_R1_S1_QA