Safety Conditions

Before open the paste please read SDS File:ED7100 OSHA MSDS.pdf for the paste. Be sure that the following are available:

Ventilation

Working with paste is highly recommended under a good ventilation area, the hood is a good environment for work.

Poor Ventilation area

Wear a well fitted NIOSH approved or industrial type canister mask.

Paste Splashing

1- Gloves,goggles.

2- suitable protection clothes.

3- sack of sand or absorber for cleaning the area.

Technical procedure

Using the paste is summarized by the following steps:

a- Look at the safety conditions needed to use the paste.
b- Equipment And Tools

55 to 77T polyester mesh, 200 mesh stainless steel screen, ER7 reducer, SW100, Oven, Multimeter, different shapes of Copper ( mainly 10X10 plate, wires), power supply.

c- Processing

1- Printing the paste using 55 to 77T polyester mesh. For tight resistances tolerance use 200 mesh stainless steel screen to reduce the distortion.

2- Clean the screen and stencil of the paste residues using SW100

3-Let the paste dry, recommended drying conditions are in the table below:

4- Curing for 1 - 2h 30min. at 150 - 165 degrees Celsius.(Contact the company for IR-curing)