EG1 Teleconferences DeltaDoverD

From New IAC Wiki
Revision as of 15:59, 12 February 2009 by Oborn (talk | contribs) (→‎Electrons)
Jump to navigation Jump to search

2/12/09

An estimate of the pion contamination in the electron candidates from the 5 GeV data set appears below. Cuts are applied on the electron candidates based on the ratio of the energy deposited by the electron candidate in the electron calorimeter to the particles momentum measured by track reconstruction using hits in the drift chamber [math]\left ( \frac{E}{p} \right )[/math]. As reported at the last teleconference on 1/20/09, these cuts were taken from Media:Yelena_Prok_Measurement_of_The_Spin_structure_Function_of_The_Proton_in_The_Resonance_Region_Thesis.pdf and applied to the 5 GeV data sample. The number of photoelectrons measured by the cherenkov detector is shown below. The goal is to estimate the number of pions which contaminate the electron candidate sample. This is done by fitting the photoelectron distribution to 2 gaussian distributions and a Landau distribution. Integrals of the fits over the region of interest are used to determine the pion contamination to the electron candidates.

Josh's Pion cuts code

Number of photoelectrons and EC_tot/P vs nphe for Pions and Electrons when e_momentum < 3 GeV

E momentum vs ec tot without cuts.gifE momentum vs ec tot with cuts.gif


Momentum (GeV) [math]EC_{tot}[/math]/P [math]EC_{inner}[/math]/P Cherenkov cut
e_momentum<3 >0.2 >0.08 nphe>2.5


The number of photoelectrons without cuts
The number of photoelectrons after cuts on [math]EC_{tot}/P[/math], [math]EC_{inner}/P[/math] and e_momentum
The number of photoelectrons after cuts on [math]EC_{tot}/P[/math], [math]EC_{inner}/P[/math], e_momentum and nphe


Distributions amplitude mean width amplitude mean width
without cuts with cuts([math]EC_{inner}/P\gt 0.08[/math], [math]EC_{tot}/P\gt 0.2[/math], e_momentum<3 GeV)
gauss(0) p0=8.788e+06 +\-12727 p1=6.139 +\-0.010 p2=5.824 +\-0.004 p0=4.604e+06 +\-6281 p1=6.956 +\-0.010 p2=6.056 +\-0.005
landau(3) p3=3.872e+07 +\-112178 p4=3.19 +\-0.01 p5=2.488 +\-0.003 p3=1.426e+07 +\-56395 p4=4.032 +\-0.008 p5=2.497 +\-0.004
gauss(6) p6=2.727e+07 +\-8868 p7=1.094 +\-0.000 p8= 0.5347 +\-0.0002 p6=9.694e+06 +\-4903 p7=1.116 +\-0.000 p8= 0.5185 +\-0.0004



1.) Electrons in the sample

Gauss 0 2.gifLandau 3 2.gifGauss 6 2.gif

Electrons in the sample(using all cuts except nphe>2.5) =
[math] = \frac {Integral(gauss(0))}{Integral(gauss(0) + landau(3) + gauss(6))} =[/math]
[math] = \frac{6.104 \times 10^9}{ 6.104 \times 10^9 + 2.925 \times 10^9 + 1.241 \times 10^9} = [/math]
[math] = 60 % [/math]


2.) Electrons in the sample using all cuts including nphe>2.5 cut

Gauss 0 3.gifLandau 3 3.gifGauss 6 3.gif

Electrons in the sample(including nphe>2.5 cut) =
[math] = \frac {Integral(gauss(0))}{Integral(gauss(0) + landau(3) + gauss(6))} =[/math]
[math] = \frac{5.367 \times 10^9}{ 5.367 \times 10^9 + 2.434 \times 10^9 + 4.928 \times 10^6} = [/math]
[math] = 69 % [/math]


Conclusion
Using only EC cuts, electrons in the sample are 60 %, after using the cut on the number of photoelectrons the pion contamination decreased and 69 % of the particles are electrons, that means pion contamination is 31 %. It decreased by 9 %.
For Pions

In this case, Josh's pion cut code was used. The number of entries decreased by ~ 20 %.

[math]EC_{tot}[/math]/P vs nphe for pions without cuts
[math]EC_{tot}[/math]/P vs nphe for pions using Josh's pion cuts code
For Electrons

In order to remove the peak around ~ 1.5 PE and some high energy pions which have enough energy to cause the Cherenkov radiation the cut on nphe was applied. The number of entries after applying the following cuts - [math]EC_{inner}/P\gt 0.08[/math] [math]EC_{tot}/P\gt 0.2[/math], e_momentum < 3 GeV and nphe > 2.5 decreased by 65.31 %.

[math]EC_{tot}[/math]/P vs nphe for electrons without cuts
[math]EC_{tot}[/math]/P vs nphe for electrons after cuts on [math]EC_{tot}/P[/math], [math]EC_{inner}/P[/math], e_momentum and nphe

Number of photoelectrons and EC_tot/P vs nphe for Pions and Electrons when e_momentum > 3 GeV

Momentum (GeV) [math]EC_{tot}[/math]/P [math]EC_{inner}[/math]/P Cherenkov cut
e_momentum<3 >0.24 >0.06 nphe>0.5


The number of photoelectrons without cuts
The number of photoelectrons after cuts on [math]EC_{tot}/P[/math], [math]EC_{inner}/P[/math] and e_momentum
The number of photoelectrons after cuts on [math]EC_{tot}/P[/math], [math]EC_{inner}/P[/math], e_momentum and nphe


Distributions amplitude mean width amplitude mean width
without cuts with cuts([math]EC_{inner}/P\gt 0.06[/math], [math]EC_{tot}/P\gt 0.24[/math], e_momentum>3 GeV)
gauss(0) p0=8.788e+06 +\-12717 p1=6.139 +\-0.01 p2=5.824 +\-0.004 p0=3.087e+06 +\-1393 p1=7.038 +\-0.002 p2=4.573 +\-0.001
landau(3) p3=3.872e+07 +\- 112058 p4=3.19 +\-0.01 p5=2.488 +\-0.003 p3=1.774e+07 +\-12968 p4=3.797 +\-0.002 p5=1.398 +\-0.001
gauss(6) p6=2.727e+07 +\- 8869 p7=1.094 +\- 0.000 p8= 0.5347 +\- 0.0002 p6=3.285e+06 +\-3512 p7=1.198 +\-0.000 p8= -0.4637 +\-0.0005



1.) Electrons in the sample

Gauss 0 2 1.gifLandau 3 2 1.gifGauss 6 2 1.gif

Electrons in the sample(using all cuts except nphe>0.5) =
[math] = \frac {Integral(gauss(0))}{Integral(gauss(0) + landau(3) + gauss(6))} =[/math]
[math] = \frac{3.32 \times 10^9}{ 3.32 \times 10^9 + 2.291 \times 10^9 + 3.8 \times 10^8} = [/math]
[math] = 55 % [/math]

2.) Electrons in the sample using all cuts including nphe>0.5 cut

Gauss 0 2 2.gifLandau 3 2 2.gifGauss 6 2 2.gif

Electrons in the sample(all cuts) =
[math] = \frac {Integral(gauss(0))}{Integral(gauss(0) + landau(3) + gauss(6))} =[/math]
[math] = \frac{ 3.269 \times 10^9}{ 3.269 \times 10^9 + 2.285 \times 10^9 + 3.571 \times 10^8} = [/math]
[math] = 55 % [/math]

Conclusion
The pion contamination is this case is the same as it was before using the cut nphe>0.5 cut. The pion contamination is 45 % in the sample.


For Pions

In this case, Josh's pion cut code was used. The number of entries decreased by ~ 20 % .

[math]EC_{tot}[/math]/P vs nphe for pions without cuts
[math]EC_{tot}[/math]/P vs nphe for pions using Josh's pion cuts code
For Electrons

In order to remove the peak around ~ 1.5 PE and some high energy pions which have enough energy to cause the Cherenkov radiation the cut on nphe was applied. The number of entries after applying the following cuts - [math]EC_{inner}/P\gt 0.06[/math] [math]EC_{tot}/P\gt 0.24[/math], e_momentum > 3 GeV and nphe > 0.5 decreased by 73 %.

[math]EC_{tot}[/math]/P vs nphe for electrons without cuts
[math]EC_{tot}[/math]/P vs nphe for electrons after cuts on [math]EC_{tot}/P[/math], [math]EC_{inner}/P[/math], e_momentum and nphe

1/29/09

We are interested in measuring the semi-inclusive pion asymmetry for both proton and deuteron targets using the 5-6 GeV EG1b data set. Our goal will be to investigate fragmentation and establish a procedure for extracting [math]\frac{\Delta d}{d}[/math] within the CLAS 12 GeV program. We begin the analysis using the EG1 DSTs created from "cooked" data files. Our first goal is evaluate the cuts used by others to improved the identification of scattered electrons in the data sample.

Cherenkov signal

Cherenkov PE Calculation

As shown in the wiki section, Particle_Identification#Cherenkov, the expected number of photoelectrons produced by electrons traversing the CLAS cherenkov detector would be
[math] N = 19 \times 10^{-9} \times 0.7 m [\frac{10^9}{m}] = 13.3 [/math]

if you assume a [math]\beta[/math] of 1 for the detected electrons in our data sample.

The expected number of photoelectrons in the CLAS cherenkov detector for reconstructed pion energies in the EG1 data set is shown in the graph below.

Pi momentum vs numb of photons 27095 theory.gif


Our theoretical expectation, based on the description of the CLAS cherenkov detector suggests, that pions can generate up to about 10 photoelectrons compared with the 13 photoelectrons that can be generated by electrons. While the cherenkov detector can distinguish a 4 photoelectron signal generated by pions of momentum 3 GeV or less from the 10 photoelectrons generated by the typical detected electron, high momentum pions would generate photoelectron signals which are comparable to the photoelectrons generated by an electron.

Measured CLAS Cherenkov signal

Electrons

track reconstructed using 5 superlayers

The cherenkov signal measured in CLAS for particles identified as electrons by the tracking algorithm is shown below. There are two distributions present. One distribution is centered around 0.7 PEs and the second distribution is at 5.3 PEs when two gaussians and a Landau distribution are combined and fit to the spectrum.

PE Fit equation (Osipenko's CLAS Note 2004-20 File:CLAS Note-2004-020.pdf)
[math]N_{pe}= p_0 e^{-0.5 \left (\frac{x-p_1}{p_2} \right )^2} + p4\frac{1}{1-\left(\frac{x-p5}{p6}\right )} + p_6 e^{-0.5 \left (\frac{x-p_7}{p_8} \right )^2}[/math]
Th CLAS note above says 2 Poisson convolution by a gaussian are used to fit NPE histogram.  The Poisson distribution starts to look like a gaussian when the Poisson mean value is larger than 4.  Our electron candidates theoretically have NPE = 13 and pions have NPE>2.5 when the reach cherenkov threshold energies.

As we will show below, the first peak is due to the misidentification of a negative pion as an electron.

track reconstructed using 6 superlayers

Reconstruction of an electrons trajectory through the CLAS drift chambers can be done using either 5 or 6 super layers. Do tracks reconstructed using 5 superlayers generate cherenkov signals which differ from tracks reconstructed using all 6 DC superlayers? The track reconstruction algorithm records the number of superlayers used for the track reconstructions. This number is recorder in the EG1 DST files within the "flag" variable. If the "flag" variable in the DST is larger than 10, then 6 superlayers were used for the track reconstruction. The cherenkov spectrum below is observed for particles identified as electrons in the EG1 data in which 6 superlayers have been used to determine their trajectory.

The table below compares the cherekov spectrum fit values for particles identified as electrons with and without the 6 superlayer requirement. If 6 superlayers are required for the electron reconstruction, the high PE gaussian distribution mean changes from 5.3 PEs to 3.8 PEs and is not not consistent within 2 standard deviations of the fit errors. The LOW PE gaussian distribution, the suspected pion contamination, mean changes from 0.7 to 1.0 PEs. The cuts decreases the number of entries by 37.17 %. It is believed that the Gaussian distribution centered around 1 PE is due to high energy pions(>2.5GeV). Neither of these distributions is consistent with the theoretical predictions made above suggesting that there are some light collection inefficiencies within the cherenkov detector.

Table: Cherenkov fit values

Distributions amplitude mean width amplitude mean width
without cuts with cut(flag>10)
gauss(0) p0=2144+/-44.0 p1=5.342+/-0.343 p2=7.761+/-0.188 p0=1580+/-8.1 p1=3.75+/-0.06 p2=8.486+/-0.042
landau(3) p3=4.349e+04+/-2894 p4=1.049+/-0.026 p5=0.2197+/-0.0257 p3=8600+/-3648.7 p4=-3.861+/-1.414 p5=-4.88+/-1.41
gauss(6) p6=4960+/-270.6 p7=0.7345+/-0.0983 p8=0.8885+/-0.0594 p6=6219+/-54.2 p7=1.088+/-0.006 p8=0.6037+/-0.0052



The plots below show the event population intensity as a function of the electron candidates momentum measured by tracking and the number of photoelectrons observed in the cherenkov detector


Experiment B>0 without cuts flag>10 5<nphe<15 5<nphe<15 and flag>10
E momentum vs numb of photoelectrons 27095 exp without cuts 2.gif E momentum vs numb of photoelectrons 27095 exp with cuts flag 10 2.gif E momentum vs numb of photoelectrons 27095 exp with cuts ? nphe ?.gif E momentum vs numb of photoelectrons 27095 exp with cuts 5 nphe 15 flag 10.gif

Pions([math]\pi^-[/math])

[math]\pi^-[/math]_Momentum_vs_Number_of_Photons

The histograms presented below show the event population intensity for the pion momentum and the number of photoelectrons generated by the pions. One can see that after applying cuts on NPhE and flag the mean value is around 1.


Experiment B>0 without cuts e_flag>10 0<e_nphe<5 0<nphe<5 and e_flag>10
Pi momentum vs numb of photoelectrons 27095 exp without cuts 2 1.gif Pi momentum vs numb of photoelectrons 27095 exp with cuts flag 10 2 1.gif Pi momentum vs numb of photoelectrons 27095 exp with cuts ? nphe ?.gif Pi momentum vs numb of photoelectrons 27095 exp with cuts 0 nphe 5 flag 10.gif

Electron-pion contamination

Osipenko's CLAS Note 2004-20 File:CLAS Note-2004-020.pdf

EC_tot/P_vs_Number_of_Photoelectrons and EC_inner/P_vs_Number_of_Photoelectrons

Two types of cuts were applied on the distributions below, one on the energy deposited to the inner calorimeter [math]EC_{inner}/P\gt 0.08[/math] and another one on the total energy absorbed by the calorimeter [math]EC_{tot}/P\gt 0.2[/math], to improve the electron particle identification. In this case we used the DST file dst27095_05, the beam energy is 5.735 GeV and target NH3.

without cut [math]EC_{tot}/P[/math]_vs_nphe([math]EC_{tot}/P\gt 0.2[/math]) [math]EC_{inner}/P[/math]_vs_nphe ([math]EC_{inner}/P\gt 0.08[/math]) [math]EC_{tot}/P[/math]_vs_nphe([math]EC_{inner}/P\gt 0.08[/math])
Ec tot momentum vs numb of phe 27095 without cut.gif Ec tot momentum vs numb of phe 27095 with cut.gif Ec inner momentum vs numb of phe 27095 with cut ec inner momentum 0.08.gif Ec tot momentum vs numb of phe 27095 with cut ec inner momentum 0.08.gif


[math]EC_{inner}/P[/math]_vs_nphe([math]EC_{tot}/P\gt 0.2[/math]) [math]EC_{tot}/P[/math]_vs_nphe([math]EC_{tot}/P\gt 0.2[/math] and [math]EC_{inner}/P\gt 0.08[/math]) [math]EC_{inner}/P[/math]_vs_nphe ([math]EC_{tot}/P\gt 0.2[/math] and [math]EC_{inner}/P\gt 0.08[/math])
Ec inner momentum vs numb of phe 27095 with cut ec tot momentum 0.2.gif Ec tot momentum vs numb of phe 27095 with cut ec inner momentum 0.08 and ec tot momentum 0.2.gif Ec inner momentum vs numb of phe 27095 with cut ec tot momentum 0.2 and ec inner momentum0.08.gif




Go Back EG1