Line 18: Line 18:
  
 
[[File:r3833_1WireHitsCol9N.png | 200 px]]
 
[[File:r3833_1WireHitsCol9N.png | 200 px]]
 +
 +
 +
If I now require that Wires 1-3 and 5-6 from column 9 have hits and then ask how many hits did wire 4 have I get an efficiency of about 98%.
 +
 +
[[File:r3833_1WireHitsCol9n5wires.png | 200 px]]
  
 
[[CLAS12_R1_S1_QA]]
 
[[CLAS12_R1_S1_QA]]

Revision as of 20:01, 7 March 2013

My first attempt at an efficiency measurement compares wire hits when you require that the first (wire 1) and last (wire 6) wires in a single super layer are hit.

First I looked at which wires were hit when I require that there is a hit on wire 1 and wire 2.

HV was G:F:S = 536:-750:1500 Volts


R3833 1WireHitsRow-vs-Column.png

Most of the hits are in row 9.


If I histogram all wire hits requiring a hit in both wire 1, wire 6 and row 9 I see the following

R3833 1WireHitsCol9.png

Now I divide by the number of hits seen by both wire 1 and wire 6

R3833 1WireHitsCol9N.png


If I now require that Wires 1-3 and 5-6 from column 9 have hits and then ask how many hits did wire 4 have I get an efficiency of about 98%.

R3833 1WireHitsCol9n5wires.png

CLAS12_R1_S1_QA