Using the paste is summarized by the following steps:
; Aim:
ED7100 paste thickness effect on the electrical resistance of copper based material.


; a- Look at the safety conditions needed to use the paste.
; a- Look at the safety conditions before using the paste.


; b- Equipment And Tools:
; b- Equipment And Tools:
55 to 77T polyester mesh, 200 mesh stainless steel screen, ER7 reducer, SW100, Oven, Multimeter, different shapes of Copper ( mainly 10X10 plate, wires), power supply.
55 to 77T polyester mesh, 200 mesh stainless steel screen, ER7 reducer, SW100, Oven, Multimeter, different shapes of Copper ( mainly 10X10 plate, wires), power supply, A pair of scissors, pliers, micrometer.


; c- Processing:
; c- Before Processing Measurements:
1- Printing the paste using 55 to 77T polyester mesh. For tight resistances tolerance use 200 mesh stainless steel screen to reduce the distortion.
 
Measure the values of the resistors of each copper shape (if possible)using the multimeter or the multimeter and the power supply. 
 
; d- Paste Processing:
1- Printing the paste using 55 to 77T polyester mesh. For tight resistances tolerance use 200 mesh stainless steel screen to reduce the distortion. try to get a uniform surface.


2- Clean the screen and stencil of the paste residues using SW100
2- Clean the screen and stencil of the paste residues using SW100
Line 32: Line 37:


4- Curing for 1 - 2h 30min. at 150 - 165 degrees Celsius.(Contact the company for IR-curing)  
4- Curing for 1 - 2h 30min. at 150 - 165 degrees Celsius.(Contact the company for IR-curing)  
 
 
; After Processing Measurements:
Measure the resistors again after processing and summarize the result in table or figure.




[[Neutron_TGEM_Detector_Abdel#7.2F31.2F2009]]
[[Neutron_TGEM_Detector_Abdel#7.2F31.2F2009]]

Revision as of 03:29, 27 October 2009

Safety Conditions

Before open the paste please read SDS File:ED7100 OSHA MSDS.pdf for the paste. Be sure that the following are available:

Ventilation

Working with paste is highly recommended under a good ventilation area, the hood is a good environment for work.

Poor Ventilation area

Wear a well fitted NIOSH approved or industrial type canister mask.

Paste Splashing

1- Gloves,goggles.

2- suitable protection clothes.

3- sack of sand or absorber for cleaning the area.

Technical procedure

Aim

ED7100 paste thickness effect on the electrical resistance of copper based material.

a- Look at the safety conditions before using the paste.
b- Equipment And Tools

55 to 77T polyester mesh, 200 mesh stainless steel screen, ER7 reducer, SW100, Oven, Multimeter, different shapes of Copper ( mainly 10X10 plate, wires), power supply, A pair of scissors, pliers, micrometer.

c- Before Processing Measurements

Measure the values of the resistors of each copper shape (if possible)using the multimeter or the multimeter and the power supply.

d- Paste Processing

1- Printing the paste using 55 to 77T polyester mesh. For tight resistances tolerance use 200 mesh stainless steel screen to reduce the distortion. try to get a uniform surface.

2- Clean the screen and stencil of the paste residues using SW100

3-Let the paste dry, recommended drying conditions are in the table below:

4- Curing for 1 - 2h 30min. at 150 - 165 degrees Celsius.(Contact the company for IR-curing)

After Processing Measurements

Measure the resistors again after processing and summarize the result in table or figure.