2mm thick PbBi, 10 MeV, 1 cm cylindrical incident electron distribution
 
 
G4beamline pencil beam 10 cm radius
 
<pre>
 
beam ellipse particle=e- nEvents=1000000 beamZ=0.0 beamX=0. beamY=0. \
 
        sigmaX=10.0 sigmaY=10.0 sigmaXp=0.000 sigmaYp=0.000 \
 
      meanMomentum=10. sigmaE=0. maxR=10.
 
</pre>
 
 
Incident Electron spatial distribution and energy
 
 
[[File:PbBi_5-1-15_X-Yposition.png | 200 px]][[File:PbBi_5-1-15_Ein.png | 200 px]]
 
 
Positron and Electron Momentum after the converter
 
 
[[File:PbBi_5-1-15_Ppositron.png | 200 px]][[File:PbBi_5-1-15_Pelectron.png | 200 px]]
 
 
{| border="1"
 
| PbBi Thickness (mm) || #positrons/million electrons (G4Beamline)|| #positrons/million electrons (MCNPX)
 
|-
 
| 1    || 1169,1083,1068,1090,1088 =1100<math>\pm</math> 40|| 1091
 
|-
 
| 1.5    || 1723, 1668,1671, 1687,1726=1695<math>\pm</math> 28 || 1728
 
|-
 
| 2    || 1902,1921,1886,1967,1922=1920<math>\pm</math> 30 || 1984
 
|-
 
| 3|| 1920,1880,1883,1864,1857=1881 <math>\pm</math> 24|| 1986
 
|-
 
| 4||1688, 1766, 1712, 1709, 1753=1726<math>\pm</math> 33 || 1858
 
|-
 
| 5||  1569,1585,1509 ,1536,1551=1550<math>\pm</math> 29 || 1646
 
|-
 
| 7|| 1475,1450,1457,1428,1477 =1457<math> \pm</math> 20 || 1541
 
|-
 
| 10|| 1250,1180,1178,1186,1166=1192<math>\pm</math> 33|| 1216
 
|-
 
|}
 
 
[[File:G4Bl-vs-MCNPX_5-5-2015.png| 200 px]]
 
  
 
===Energy Deposition in Target system (Heat)===
 
===Energy Deposition in Target system (Heat)===

Revision as of 14:12, 13 May 2015

Development of a Positron source using a PbBi converter and a Solenoid

Converter target properties

Definition of Lead Bismuth


1cm diameter target 2 mm thick PbBi

0.5 Tesla solenoid


Desire to know

Emmittance (mrad * mm)

dispersion (Delta P/P) (mradian/1000th mm/1000th)

of electrons after the PbBi target.


pole face rotation in vertical plane.

G4BeamLine and MCNPX

Target thickness optimization

PbBi_THickness_GaussBeam

PbBi_THickness_CylinderBeam

Energy Deposition in Target system (Heat)

Layout.png

ElectronTracks.pngPhotonTracks.png

ElectronEnergy.pngPhotonEnergy.png

MCNPX simulations of energy deposition into different cells are below. There is a slight overestimate (they add up to about 120%). Positrons contribute less than 1% of electrons' contribution. No magnetic filed is assumed.

Model.png

Tablen1.png

Tablen2.png

2mm thick PbBi, 10 MeV, point source

G4beamline pencil beam 10 cm radius

beam ellipse particle=e- nEvents=1000000 beamZ=0.0 beamX=0. beamY=0. \
        sigmaX=10.0 sigmaY=10.0 sigmaXp=0.000 sigmaYp=0.000 \
      meanMomentum=10. sigmaE=0. maxR=10.
PbBi Thickness (mm) #positrons/million electrons (G4Beamline) #positrons/million electrons (MCNPX)
1 1091
1.5 1728
2 1902[math]\pm[/math] 43 1984
2.5 2062
3 [math]\pm[/math] 13 1986
3.5 1938
4 [math]\pm[/math] 39 1858
5 1646
6 [math] \pm[/math] 37 1541
10 1216

Solenoid

Inner Radiusu=

Outer Radius =

Length =

Current=

Magnetic Field Map in cylindrical coordinates (Z & R) from Niowave

Beam Line Design

PbBi_BeamLine_Elements

Positrons#Simulations