| + | == operation== | ||
| − | + | 1.) pump down chamber | |
| − | |||
2.) backfill with argon to 1atm | 2.) backfill with argon to 1atm | ||
| + | |||
3.) heat top at full power by plugging into wall directly, the other heaters use a rheostat | 3.) heat top at full power by plugging into wall directly, the other heaters use a rheostat | ||
| + | |||
4.) 360 watts applied to mid center until temperature at bottom flange is 120 C | 4.) 360 watts applied to mid center until temperature at bottom flange is 120 C | ||
| + | |||
5.) turn on the other heaters at 20 % of 120 volts until the temperature warms to at least 40 C | 5.) turn on the other heaters at 20 % of 120 volts until the temperature warms to at least 40 C | ||
| − | 6.) vent if the pressure | + | |
| + | 6.) vent if the pressure goes above 2 ATM | ||
| + | |||
7.) once loop is about 40 C or more, increase rheostats to 40% of 120 volts | 7.) once loop is about 40 C or more, increase rheostats to 40% of 120 volts | ||
| + | |||
8.) top reservoir will be kept heating at full power until maxing out at 300 C then you can turn it off when bottom well is liquid | 8.) top reservoir will be kept heating at full power until maxing out at 300 C then you can turn it off when bottom well is liquid | ||
| + | |||
9.) at 70 C in the well increase reostat to 60% | 9.) at 70 C in the well increase reostat to 60% | ||
| + | |||
10.) unplugged top heater when it hits 289 C, temp in middle of loop was 280 | 10.) unplugged top heater when it hits 289 C, temp in middle of loop was 280 | ||
| + | |||
11.) when well temp was 170 C , the high power heater (right side) is increased to 100 % while all other heaters are turned off | 11.) when well temp was 170 C , the high power heater (right side) is increased to 100 % while all other heaters are turned off | ||
| − | |||
| − | + | ||
20 C difference between top center and well right | 20 C difference between top center and well right | ||
| Line 26: | Line 36: | ||
1=well left | 1=well left | ||
| − | + | ==target description== | |
20 mill windows | 20 mill windows | ||
4mm target window | 4mm target window | ||
Latest revision as of 14:43, 8 December 2014
Liquid_PbBi_Target_in_Solenoid_Magnetic_Field
Niowave Pb-Bi liquid target
operation
1.) pump down chamber
2.) backfill with argon to 1atm
3.) heat top at full power by plugging into wall directly, the other heaters use a rheostat
4.) 360 watts applied to mid center until temperature at bottom flange is 120 C
5.) turn on the other heaters at 20 % of 120 volts until the temperature warms to at least 40 C
6.) vent if the pressure goes above 2 ATM
7.) once loop is about 40 C or more, increase rheostats to 40% of 120 volts
8.) top reservoir will be kept heating at full power until maxing out at 300 C then you can turn it off when bottom well is liquid
9.) at 70 C in the well increase reostat to 60%
10.) unplugged top heater when it hits 289 C, temp in middle of loop was 280
11.) when well temp was 170 C , the high power heater (right side) is increased to 100 % while all other heaters are turned off
20 C difference between top center and well right
4 = top center 3=center left 2 = well right 1=well left
target description
20 mill windows 4mm target window
5 kg of eutectic 45/55 ratio
Heat tape is rated at120 volts at 300 watts