Using PAA ro measure Selenium concentrations.
According to Krouse<ref name="Krous1962"> H.R. Krause and H.G. Thode,"Thermodynamic Properties and Geochemistry of Iosotopic Compounds of Selenium",.Can. J. Chem., vol 40, pg 367</ref> , the fractional concentration of Se-82/Se-76 in plant material is observed to be less than from primordial (meteoric) concentrations by as much as 1.2%. Anaerobic bacteria are known to reduce selenates and senelites in biological systems. This may be the reason plant material has fractionation of selenium isotopes. They also observe excess concentrations of up to 0.4% in soil.
Plant material appears to detect environmental selenium.
Can one use plant material to measure the provenance of selenium?
Natural abundance of selenium
Isotope | Abundance |
Se-74 | 0.86% |
Se-76 | 9.23% |
Se-77 | 7.60% |
Se-78 | 23.69% |
Se-80 | 49.80% |
Se-82 | 8.82% |
Possible reactions
Reaction | Half-life | Relative activity | Gamma-rays, keV (BR) |
Se-74(gamma,n)Se-73 | 7.1 h | 1.5E-1 | 361 (100) |
Se-74(gamma,n)Se-73m | 39 m | 3.2 | 402 (4) |
Se-74(gamma,np)As-72 | 26 h | 1.0E-3 | 834 (100) |
Se-76(gamma,n)Se-75 | 120 d | 1.3E-2 | 265(29) |
Se-77(gamma,p)As-76 | 26.4 h | 4.4E-2 | 559(44) |
Se-78(gamma,p)As-77 | 38.8 h | 8.6E-2 | 239(2) |
Se-80(gamma,n)Se-79m | 3.9 m | 5.9 | 96(10) |
Se-80(gamma,np)As-78 | 1.5 h | 2.2E-2 | 614(54) |
Se-80(gamma,p)As-79 | 8.2 m | 1.3 | 96(9) |
Se-80(gamma, | p)Ge-7583 m | 2.8E-1 | 265(11) |
Can one perform PAA measurements of Se-82 and Se-76?
Experiments
Preliminary Information Before Irradiation of Soil Sample
Using Detector D at the IAC, I had to get a count on the unirradiated soil sample that was collected. Here are the GPS coordinates ****
Here is the spectrum produced:
The details of the calibration along with the constants found from a linear fit of temperature vs. voltage can be found in the page below.
Calibration 10-21-16 Det D Calibration 10-28-16 Det A
Nickel Normalization
Talk about Nickel reaction, give example of Nickel rates for 511 and 1377 keV lines. Run condition for examples below.
Using a 45 MeV linac (Jack) you get 75 uCi of Nickel per (gram Kw hr)
If using a 25 meV machine at 1 kW power, how ling should I run to keep 1 g of natural Selium from having a Se-79 Activiy less than 16 pCi?
Here is the data for the cross section of Ni-58( ,n)Ni-57 data
http://www-nds.indcentre.org.in/exfor/servlet/X4sGetSubent?reqx=119235&subID=220597006&plus=1
When comparing this data to the Se-80(
,n)Se-79 reaction, we must be careful when handling the bin sizes. The data for the Se-79 reaction is binned by intervals of 0.2 MeV, while the Ni-57 data is binned by intervals of 0.1 MeV. To create coarser bins, I must take the 3 data points from the Nickel data and get an average value, then plot that value centered at the midpoint of these two values. For example, I would take 10.1,10.2, and 10.3 MeV and average their values and plot at 10.2 MeV. Below is the plot:Here is the data for the plot above. The Zn-68 -> Cu-67 data was found in the IAEA handbook on page 160. I used data thief to find the points that were plotted.
Energy (MeV) | Zn-68 -> Cu-67 (mb) | Ni-58 -> Ni-57 | Se-80 -> Se-79 |
12.0 | 0.0103 | ** | 33.8 +/- 1.8 |
12.2 | 0.0117 | 0.56 +/- 0.2 | 35.6 +/- 1.7 |
12.4 | 0.0128 | 1.56 +/- 0.2 | 40.8 +/- 1.9 |
12.6 | 0.0624 | 2.83 +/- 0.2 | 42.3 +/- 1.5 |
12.8 | 0.1496 | 4.23 +/- 0.2 | 47.4 +/- 2.2 |
13.0 | 0.2113 | 5.13 +/- 0.2 | 51.6 +/- 2.8 |
13.2 | 0.3149 | 5.53 +/- 0.2 | 54.8 +/- 2.6 |
13.4 | 0.5009 | 5.93 +/- 0.2 | 61.9 +/- 2.8 |
13.6 | 0.642 | 6.6 +/- 0.2 | 69.5 +/- 2.4 |
13.8 | 0.7151 | 7.46 +/- 0.2 | 74.4 +/- 3.3 |
14.0 | 0.8874 | 8.79 +/- 0.2 | 82.8 +/- 3.8 |
14.2 | 0.9466 | 9.87 +/- 0.2 | 94.1 +/- 3.4 |
14.4 | 0.9884 | 10.41 +/- 0.2 | 94 +/- 3.6 |
14.6 | 1.113 | 10.47 +/- 0.2 | 102 +/- 3.4 |
14.8 | 1.337 | 10.92 +/- 0.2 | 107.3 +/- 4.3 |
15.0 | 1.411 | 11.71 +/- 0.2 | 111.3 +/- 4.7 |
15.2 | 1.4574 | 12.76 +/- 0.2 | 115.6 +/- 4.7 |
15.4 | 1.6059 | 14.09 +/- 0.2 | 119.9 +/- 5 |
15.6 | 1.641 | 15.76 +/- 0.2 | 120.1 +/- 5.3 |
15.8 | 1.7318 | 18.13 +/- 0.2 | 126 +/- 7.3 |
16.0 | 1.7506 | 21.22 +/- 0.2 | 122.9 +/- 7.3 |
16.2 | 2.0141 | 22.89 +/- 0.2 | 114.6 +/- 5 |
16.4 | 2.2435 | 23.13 +/- 0.2 | 122.4 +/- 6.1 |
16.6 | 2.3172 | 22.84 +/- 0.2 | 121.2 +/- 7.7 |
16.8 | 2.6092 | 22.61 +/- 0.2 | 118.2 +/- 9.1 |
17.0 | 2.6947 | 22.31 +/- 0.22 | 116.8 +/- 8.8 |
17.2 | 2.9378 | 22.86 +/- 0.39 | 116.4 +/- 5.9 |
17.4 | 3.1341 | 24.23 +/- 0.46 | 109.5 +/- 7.4 |
17.6 | 3.3798 | 25.8 +/- 0.54 | 109.6 +/- 8.3 |
17.8 | 3.2368 | 27.12 +/- 0.63 | 102.3 +/- 8.1 |
18.0 | 4.0164 | 27.38 +/- 0.63 | 107.2 +/- 8.3 |
18.2 | 4.4739 | 26.5 +/- 0.62 | 111.9 +/- 8 |
18.4 | 4.5713 | 25.18 +/- 0.64 | 101.3 +/- 8.3 |
18.6 | 4.6206 | 24.16 +/- 0.64 | 97 +/- 7.5 |
18.8 | 5.1468 | 23.31 +/- 0.71 | 93.4 +/- 7.9 |
19.0 | 5.0914 | 22.38 +/- 1.10 | 90.5 +/- 7.1 |
19.2 | 5.6712 | 20.84 +/- 1.71 | 87.1 +/- 7.4 |
19.4 | 6.525 | 19.18 +/- 1.51 | 89.7 +/- 7.8 |
19.6 | 6.8866 | 19.93 +/- 1.10 | 90.6 +/- 6.3 |
19.8 | 6.9607 | 24.06 +/- 1.3 | 90.3 +/- 6.3 |
20.0 | 7.6705 | 29.25 +/- 0.9 | 84.9 +/- 7 |
20.2 | 8.1832 | 31.17 +/- 0.69 | 79 +/- 6.2 |
20.4 | 8.4519 | 29.6 +/- 0.69 | 75.5 +/- 7.9 |
20.6 | 8.8241 | 27.06 +/- 0.87 | 74.1 +/- 6.5 |
20.8 | 9.5163 | 26.29 +/- 0.82 | 75.4 +/- 6.4 |
21.0 | 9.9354 | 25.4 +/- 0.72 | 72.9 +/- 7.4 |
21.2 | 10.0428 | 23.07 +/- 0.76 | 67.6 +/- 5.6 |
21.4 | 10.151 | 21.84 +/- 0.84 | 69.1 +/- 8.3 |
21.6 | 10.1502 | 23.90 +/- 0.79 | 57.2 +/- 7.7 |
21.8 | 10.149 | 25.98 +/- 0.88 | 61 +/- 7.6 |
22.0 | 9.9323 | 25.64 +/- 1.27 | 58 +/- 7.6 |
22.2 | 9.9316 | 21.39 +/- 2.20 | 57.8 +/- 6.4 |
22.4 | 9.7191 | 17.49 +/- 1.49 | 65.8 +/- 9.6 |
22.6 | 9.3077 | 15.82 +/- 0.82 | 59.9 +/- 6.9 |
22.8 | 8.9141 | 15.85 +/- 0.76 | 55.7 +/- 8.4 |
23.0 | 8.7229 | 16.79 +/- 1.10 | 53.4 +/- 7.3 |
23.2 | 8.6287 | 17.07 +/- 0.86 | 57.5 +/- 7.8 |
23.4 | 8.2638 | 15.93 +/- 0.93 | 32 +/- 7.8 |
23.6 | 8.0867 | 12.61 +/- 0.84 | 43.7 +/- 7.8 |
23.8 | 7.8288 | 8.76 +/- 0.87 | 36.5 +/- 9.8 |
24.0 | 7.5787 | 6.96 +/- 0.78 | 39.7 +/- 7.2 |
24.2 | 7.8 | 6.45 +/- 0.86 | 37.3 +/- 8.5 |
Using a left handed Riemann Sum on each set of cross section data (The Selenium 79 reaction and the Nickel 58 reaction), the relative activity between the nickel isotopes and the selenium isotopes can be found. For the Nickel reaction I used a rectangular width equal to the bin size of the measurements, which was 0.1 MeV. Similarly for the selenium I had to use a bin size of 0.2 MeV while rounding the values down to the nearest tenth, i.e. 10.02 becomes 10.0, 10.22 becomes 10.2 and so on.
Reaction | Integrated Cross Section (mb)[12->24 MeV] | Abundance |
Se-80(gamma,n)Se-79 | 5051.1 | 49.8% |
Ni-58(gamma,n)Ni-57 | 1074.99 | 68.1% |
Zn-68(gamma,p)Cu-67 | 293.2027 | 18.45 % |
Se-76(gamma,n)Se-75 | 4598.8 | 9.23 |
Se-82(gamma,n)Se-81 | 5219.89 | 8.2 |
Reaction | Integrated Cross Section (mb)[12.2->18.2 MeV] | Abundance |
Se-80(gamma,n)Se-79 | 2892 | 49.8% |
Ni-58(gamma,n)Ni-57 | 451.63 | 68.1% |
Zn-68(gamma,p)Cu-67 | 46.0847 | 18.45 % |
Se-76(gamma,n)Se-75 | 2644.7 | 9.23% |
Se-82(gamma,n)Se-81 | 3271.3 | 8.82% |
Here Segebade has the inverse of this expression, so taking the inverse we have my 0.58 compared to Segebade's 0.54
So now using 0.46g of Selenium pellets. I will calculate the expected activity for Se-82
= 108.6
Now using 34.5 uCi/h (Assuming 1kW and 0.46g of Selenium) we get an expected activity of 108.6*34.5uCi/h = 3.7mCi/h of Se-81. So in 2 hours we will have 7.4mCi of Se-81
Here Segebade has the inverse of this expression, so taking the inverse we have my 0.58 compared to Segebade's 0.013
So using 0.46g of selenium, I will calculate the expected activity for Se-75
= 0.01
Now using 34.5 uCi/h (Assuming 1kW and 0.46g of selenium) we get an expected activity of 0.01*(34.5uCi/h) = 0.345 uCi/h. So in 2 hours the expected activity will be 0.69uCi
= 0.000000043
Now using the production rate ratio above from the nickel we can determine that the production rate of Se-79 is 3.243pCi/h, this would mean that we could irradiate for 4.9 hours before reaching the threshold of 16pCi.
Segebade has a table of ratios of specific activities of certain elements compared to Ni-57. The section starts on page 167, but the ratios with selenium are found on page 176
Since the beam energy has been changed to 18 MeV, I will recalculate the expected yield with respect to nickel
= 0.000000066
Now 75 microCi/h (assuming 1 kW and 1 g of natural selenium) 75(microCi/h)*0.000000066 = 0.000004949 microCi/h = 4.9 pCi/h, so we can irradiate for 3.27 hours before we hit 16 pCi.
Chlorine
It looks like Cl-35 is abundant as you see photon energies of 146 keV and 2127 keV (you can barely see 1176 keV) from Cl-34's decay (neutron knocked out of Cl-35).
The half life is 32 minutes.
Should check the half life from the run AccOnAlInDetASe-AinDetD_001.root using the calibration
MPA->Draw("0.18063+0.960133*evt.Chan>> SeRun_008(8000,0.5,8000.5)","evt.ADCid==3");
Irradiation of Horse Mineral Supplement
Below is the EMSL report for the horse feed sample. https://wiki.iac.isu.edu/index.php/File:EMSL_Report_Horse_Feed.pdf
Chlorine is a dominant signal
First, look at the peak around 146 keV
Next I plotted the counts as a function of time to get an exponentially decaying graph. When doing an exponential fit here, the parameter "b" given by root will be the decay constant.
Root gives a half life of 32.9508 +/- 0.01 minutes
Now do the same for the 2127 keV line
Here are the counts plotted as a function of time
Root gives a half life of 35.3962 +/- 0.2 minutes
Potassium is a potential signal
Looking at the spectrum for the fast irradiation sample, there are 2 prominent lines that could be from 38-K. The mechanism would be a single neutron knockout from a stable 39-K nucleus. The two most dominant energies of the three for 38-K are 2167 keV and 3936 keV and the half life is 7.63 minutes. Below is a fit to the energy spectrum histogram
Now check the half life
Root gives a half life of 8.03 +/- 0.02 minutes
Next check the 3936 peak
and check the half life
Root gives a value for b = - 1.14372x10^(-3), which in turn gives a half life of 10.1 minutes
It seems very possible that 38-K could be in the sample of horse feed.
First Observation of Se lines
Using the 44 Machine at 7 kW power and 44 meV incident electron energy to produce a bremsstrahlung spectrum with a mean energy of 15 meV.
All runs lasting less than 214 seconds have time stamp that gives real time if you divide by clock frequency of 20 MHz. The first 32 bits are used for a real time measurement.
MDA and Se mass Calculations
To find the mass of the selenium in the irradiated horse feed sample, we need some masses and volumes of the horse feed. A vial containing 20mL of regular horse feed was massed. The mass of the vial was 13.6406g and the total mass of the vial and the horse feed was 31.8504g. This means the mass of the horse feed is
. Since this mass is in a 20mL = 0.02L container, the density of the horse feed (assuming the mass difference between the non-irradiated and the irradiated horse feed is negligible) is
.
Now for the irradiated horse feed the mass of the container is 25.0259g and the total mass of the container and the sample is 43.7529g. The mass of the sample then is 43.7529g - 25.0259g = 18.727g. Now using the density found before we can find the volume of the irradiated horse feed within the container.
The EMSL report says that there are
in the horse feed, so the mass of the selenium in the horse feed sample is
.
Each of the calibration runs were used at position C in detector D. Below is the runlist for the isotopes used. The intervals used were (117:127) and (272:282) respectively.
Source | Serial # | Reference Date | Activity | Start | Stop | Live |
Co-57 | 129735 | 07/01/08 | 1.074 micro Ci | 16:17:37 | 16:27 | 601.10 |
Ba-133 | 129790 | 07/01/08 | 1.188 micro Ci | 16:29:14 | 16:32 | 208.259 |
For the Co-57, the activity as of 09/07/16 is 0.0005 microCi and the intensity of the 122.3 keV line is 85.6%
- = for the 122.3 line
For the Ba-133, the activity as of 09/07/16 is 0.69 microCi and the intensity of the 277.05 keV line is 7.164%
- = for the 277.05 line
Run | Source | Energy (keV) | Expected Rate (Hz) | HpGe Rate (Hz) | HpGe Det D Efficiency (%) |
Eff_C_Co_57.root | Co-57 | 122.3 | 15.84 | 0.4526 - 0.2144 | 1.5 |
Eff_C_Ba_133.root | Ba-133 | 277.05 | 1828.97 | 20.58 - 0.07641 | 1.12 |
Now that the efficiency has been found, we must find the background rate to find the MDA. To find the background rate I used ROOT and plotted the energy spectra for Se_B_005 and HorseFeed_NoIrr. The windows of interest are the same as above. Each run's time was cut down to 1 hour.
First I will find the MDA for the window from (117:127). In Se_B_005, the activity was found to be 0.8433 HZ and in the HorseFeed_NoIrr the activity was found to be 0.2133 Hz, which gives a background rate of 0.63 Hz -> 37.6 cpm.
Now we can compute the MDA using this reference https://wiki.iac.isu.edu/index.php/File:Nwsltr-43re.pdf
I found the MDA to be [(2.71 + 4.65*(37.6 * 60)^1/2]/(60*0.015) = 249.1 dpm
Now I will find the MDA for the window from (272:282). In Se_B_005, the activity was found to be 0.7408 Hz and in HorseFeed_NoIrr the activity was found to be 0.08278. This means that the background activity is 0.66 Hz -> 39.48 cpm.
Now we can compute the MDA = [(2.71 + 4.65*(39.48 * 60)^1/2]/(60*0.012) = 318.1 dpm
Detector Efficiency
Below is the runlist for finding the efficiency of the detector at position R
Source | Serial # | Reference Date | Activity | Start | Stop | Live |
Na-22 | 129743 | 7-01-08 | 9.427 microCi | 15:49 | 16:19 | 1796.803 |
Cs-137 | 129793 | 7-01-08 | 1.006 microCi | 14:25 | 14:56 | 1879.606 |
Mn-54 | 129807 | 7-01-08 | 11.77 microCi | 15:00 | 15:30 | 1793.420 |
Co-60 | 129740 | 7-01-08 | 10.42 microCi | 15:33 | 15:43 | 569.725 |
Below are the theoretical calculations for the theoretical decay frequencies
Na-22, 9.427micro Ci on July 1, 2008, half life 2.602 +/- 0.002 years, 99.937% for 1274.52 and 178.8 for 511 line , activity in March 31, 2016 =1.196micro Ci
- = for the 1274 line
- = for the 511 line
Cs-137, 661.660 line, 85.21% * 1.066micro Ci on July 1, 2008, half life 30.0 +/- 0.2 yrs, March 31, 2016 activity = 0.891micro Ci expected rate for 661 line
- =
Mn-54, 11.77 microCi on July 1, 2008, half life =312.20 +/- 0.07 days, 99.975% intensity on 834.826 , March 31, 2016 activity =0.02328micro Ci
- = for the 834 line
Co-60, 10.42micro Ci July 1, 2008, half life 5.271 +/- 0.001 years, 99.0 % for 1173.237 and 99.9824 % for 1332.501, March 31, 2016 activity=3.759micro Ci
- = for the 1173 line
- = for the 1332 line
Below is a table where the actual efficiency will be calculated for position R (farthest position).
Run | Source | Energy (keV) | Expected Rate (Hz) | HpGe Rate (Hz) | HpGe Det D Efficiency (%) |
Eff_003 | Na-22 | 511 | 79122.6 | (506:516) (4.309-0.065=4.244) | 0.005 |
Eff_005 | Cs-137 | 661.657 | 28091.2 | (657:666)(1.105-0.02281=1.0821) | 0.004 |
Eff_006 | Mn-54 | 834.848 | 861.1 | (830:839)(0.04037-0.009123=0.031247) | 0.004 |
Eff_007 | Co-60 | 1173.228 | 137692 | (1164:1182)(3.686-0.01939=3.67) | 0.003 |
Eff_003 | Na-22 | 1274.537 | 44224 | (1270:1279) (1.073-0.0057=1.0673) | 0.002 |
Eff_007 | Co-60 | 1332.492 | 139058.52 | (1328:1337)(3.283-0.05702=3.22598) | 0.002 |
Below is a runlist for position k
Source | Serial # | Reference Date | Activity | Start | Stop | Live |
Na-22 | 129743 | 7-01-08 | 9.427 microCi | 14:54 | 15:01 | 434.087 |
Cs-137 | 129793 | 7-01-08 | 1.006 microCi | 15:48 | 15:55 | 413.925 |
Mn-54 | 129807 | 7-01-08 | 11.77 microCi | 15:28 | 15:40 | 705.186 |
Co-60 | 129740 | 7-01-08 | 10.42 microCi | 15:41 | 15:47 | 346.092 |
Below are the theoretical decay frequencies
Na-22, 9.427micro Ci on July 1, 2008, half life 2.602 +/- 0.002 years, 99.937% for 1274.52 and 178.8 for 511 line , activity in April 14, 2016 =1.183micro Ci
- = for the 1274 line
- = for the 511 line
Cs-137, 661.660 line, 85.21% * 1.066micro Ci on July 1, 2008, half life 30.0 +/- 0.2 yrs, April 14, 2016 activity =0.890 micro Ci expected rate for 661 line
- =
Mn-54, 11.77 on July 1, 2008, half life =312.20 +/- 0.07 days, 99.975% intensity on 834.826 , April 14, 2016 activity =0.02251micro Ci
- = for the 834 line
Co-60, 10.42micro Ci July 1, 2008, half life 5.271 +/- 0.001 years, 99.0 % for 1173.237 and 99.9824 % for 1332.501, April 14, 2016 activity=3.74micro Ci
- = for the 1173 line
- = for the 1332 line
Below are the actual efficiencies for position k
Run | Source | Energy (keV) | Expected Rate (Hz) | HpGe Rate (Hz) | HpGe Det D Efficiency (%) |
Eff_k_002 | Na-22 | 511 | 79122.6 | (506:516)(49.21-0.6272=48.58) | 0.06 |
Eff_k_006 | Cs-137 | 661.657 | 28091.2 | (657:666)(12.86-0.02281=12.837) | 0.05 |
Eff_k_004 | Mn-54 | 834.848 | 861.1 | (830:839)(0.3204-0.009123=0.311) | 0.04 |
Eff_k_005 | Co-60 | 1173.228 | 137692 | (1164:1182)(42.39-0.02053=42.369) | 0.03 |
Eff_k_002 | Na-22 | 1274.537 | 44224 | (1270:1279) (12.53-0.005702)=12.52 | 0.03 |
Eff_k_005 | Co-60 | 1332.492 | 139058.52 | (1328:1337)(35.94-0.005072) | 0.03 |
Below is a runlist for position C
Source | Serial # | Reference Date | Activity | Start | Stop | Live |
Na-22 | 129742 | 7-01-08 | 1.146 microCi | 12:55 | 12:57 | 129.782 |
Cs-137 | 129793 | 7-01-08 | 1.006 microCi | 13:02 | 13:04 | 123.818 |
Mn-54 | 129806 | 7-01-08 | 1.226 microCi | 13:11 | 13:21 | 613.754 |
Co-60 | 129739 | 7-01-08 | 1.082 microCi | 13:08 | 13:09 | 103.599 |
Below are the calculations for the theoretical frequencies
Na-22, 9.427micro Ci on July 1, 2008, half life 2.602 +/- 0.002 years, 99.937% for 1274.52 and 178.8 for 511 line , activity in May 5, 2016 =1.196micro Ci
- = for the 1274 line
- = for the 511 line
Cs-137, 661.660 line, 85.21% * 1.066micro Ci on July 1, 2008, half life 30.0 +/- 0.2 yrs, May 5, 2016 activity = 0.89micro Ci expected rate for 661 line
- =
Mn-54, 1.226 microCi on July 1, 2008, half life =312.20 +/- 0.07 days, 99.975% intensity on 834.826 , May 5, 2016 activity =0.002micro Ci
- = for the 834 line
Co-60, 1.082micro Ci July 1, 2008, half life 5.271 +/- 0.001 years, 99.0 % for 1173.237 and 99.9824 % for 1332.501, May 5, 2016 activity=0.39micro Ci
- = for the 1173 line
- = for the 1332 line
Below is a table with the calculated efficiencies
Run | Source | Energy (keV) | Expected Rate (Hz) | HpGe Rate (Hz) | HpGe Det D Efficiency (%) |
Eff_C_001 | Na-22 | 511 | 9261.8 | (506:516) (45.65-0.065=45.585) | 0.5 |
Eff_C_002 | Cs-137 | 661.657 | 28059.7 | (657:666)(101.7-0.02281=101.67) | 0.4 |
Eff_C_004 | Mn-54 | 834.848 | 73.98 | (830:839)(0.2704-0.009123=0.2612) | 0.4 |
Eff_C_003 | Co-60 | 1173 | 14285.7 | (1164:1182)(34.24-0.01939=34.22) | 0.2 |
Eff_C_001 | Na-22 | 1274.537 | 5176.7 | (1270:1279) (11.15-0.0057=11.14) | 0.2 |
Eff_C_003 | Co-60 | 1332.492 | 14427.5 | (1328:1337)(28.05-0.05702=27.99) | 0.2 |
Run List
Date | Time elapsed (Seconds) | Sample | Document Title | Start | Stop | Real | Live | Position |
04-01-16 | 2.16x10^6 | Se_B | Se_B_002 | 15:55 | 09:15 | 235989.882 | 235687.660 | k |
04-06-16 | 2.592x10^6 | Se_B | Se_B_003 | 12:57 | Interrupted | computer | crash | k |
04-14-16 | 3.283x10^6 | Se_B | Se_B_005 | 15:57 | 09:37 | 63581.784 | 63509.895 | k |
04-15-16 | 3.37x10^6 | Sample D | Sample_D_001 | 14:47 | 08:23 | 236172.264 | 236173.271 | k |
04-19-16 | 3.715x10^6 | Sample B | Sample_B_001 | 15:31 | 15:18 | 85634.862 | 85624.090 | k |
4-20-16 | 3.802x10^6 | Sample C | Sample_C_001 | 15:22 | 10:19 | 68253.774 | 68232.238 | k |
04-21-16 | 3.888x10^6 | Sample A | Sample_A_001 | 10:22 | 10:37 | 87292.409 | 87268.114 | k |
04-25-16 | 4.234x10^6 | Sample E | Sample_E_001 | 11:36 | 10:03 | 80822.406 | 80795.679 | k |
04-26-16 | 4.32x10^6 | Se_B | Se_B_008 | 10:06 | 10:29 | 87784.755 | 87664.070 | k |
05-05-16 | 5.098x10^6 | Sample A | Sample_A_002 | 13:31 | 14:30 | 3605.507 | 3602.925 | c |
05-05-16 | 5.098x10^6 | Sample B | Sample_B_002 | 14:34 | 15:26 | 3114.244 | 3112.620 | c |
05-05-16 | 5.098x10^6 | Sample C | Sample_C_002 | 15:28 | 10:57 | 70124.788 | 70044.470 | c |
05-06-16 | 5.184x10^6 | Sample D | Sample_D_002 | 10:59 | 15:34 | 16516.898 | 16512.570 | c |
05-06-16 | 5.184x10^6 | Sample E | Sample_E_004 | 15:37 | 16:18 | 261654.225 | 261344.308 | c |
05-09-16 | 5.443x10^6 | Se B | Se_B_012 | 16:20 | 11:08 | 67157.101 | 66660.298 | c |
05-10-16 | 5.5296x10^6 | Sample A | Sample_A_004 | 11:03 | 15:19 | 15379.475 | 15363.017 | c |
05-10-16 | 5.5296x10^6 | Sample B | Sample_B_004 | 15:22:04 | 11:43 | 73256.181 | 73220.324 | c |
05-16-16 | 6.048x10^6 | Sample C | Sample_C_004 | 16:33 | 08:19 | 56758.980 | 56711.121 | c |
05-18-16 | 6.2208x10^6 | Sample D | Sample_D_006 | 08:44:21 | 14:05 | 19271.829 | 19266.929 | c |
05-18-16 | 6.2208x10^6 | Sample E | Sample_E_006 | 14:08 | 08:06 | 151108.258 | 150955.915 | c |
05-20-16 | 6.3936x10^6 | Se_B | Se_B_014 | 08:08:47 | 08:44 | 261353.204 | 259621.655 | c |
05-23-16 | 6.6528x10^6 | Sample A | Sample_A_006 | 08:48 | 13:49 | 18103.004 | 18091.523 | c |
05-23-16 | 6.6528x10^6 | Sample B | Sample_B_006 | 13:52 | 13:24 | 84763.938 | 84696.083 | c |
05-24-16 | 6.7392x10^6 | Sample C | Sample_C_006 | 13:28:28 | 10:28 | 75571.716 | 75502.871 | c |
05-31-16 | 7.344x10^6 | Sample B | Sample_B_008 | 08:57:22 | 08:55 | 86282.861 | 86237.392 | c |
06-01-16 | 7.4304x10^6 | Sample C | Sample_C_008 | 08:58:39 | 13:31 | 102739.504 | 102647.471 | c |
06-02-16 | 7.5168x10^6 | Sample D | Sample_D_010 | 13:33 | 08:41 | 68915.044 | 68898.246 | c |
SeRun_01-11-16
SeRun_03-07-16
SeRun_02-13-17
LB IAC Radiator Specs
LB Rotating Sample Holder
Data Analysis
Pure Se Sample
Observed lines
Estimate of Se-79 activity
Using known efficiency to extrapolate initial activity
Use ratio with Nickel foil rate
Se spiked in Soil
Detection limit of Se in Soil
References
<references/>
File:Krouse CanJournChem 40 1962 p367.pdf
Goryachev, A. M., & Zalesnyy, G. N. (n.d.). The studying of the photoneutron reactions cross sections in the region of the giant dipole resonance in zinc, germanium, selenium, and strontium isotopes. Retrieved September 16, 2016, from http://www-nds.indcentre.org.in/exfor/servlet/X4sSearch5?EntryID=220070
Goryachev, B. I., Ishkhanov, B. S., Kapitonov, I. M., Piskarev, I. M., Piskarev, V. G., & Piskarev, O. P. (n.d.). Giant Dipole Resonance on Ni Isotopes. Retrieved October 26, 2016, from http://www-nds.indcentre.org.in/exfor/servlet/X4sGetSubent?reqx=119235&subID=220597006&plus=1
Handbook on Photonuclear data for applications, cross sections, and spectra. (2000, October). Retrieved November 4, 2016, from http://www-pub.iaea.org/MTCD/Publications/PDF/te_1178_prn.pdf
MSDS