Difference between revisions of "Thesis"

From New IAC Wiki
Jump to navigation Jump to search
 
(75 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
[[Media:Thesis Dissertation-Manual.pdf]]
 +
 
=Writing=
 
=Writing=
  
Line 5: Line 7:
 
[[OSLs]]
 
[[OSLs]]
  
=Introduction=
+
[[Experimental Methods]]
 +
 
 +
[[OSL Reader]]
 +
 
 +
[[Radiation Dose Theory]]
  
=Theory=
+
[[OSL Data Analysis]]
For the sake of brevity and elegance, the reader is referred to the internet, where in due time he or she can find a fantastically large supply of papers pertaining to this study, some of which may contain content covering the necessary theory. 
 
  
==[[Related Papers/Links]]==
+
=[[Title Page]]=
see above.
 
  
==[[TriMev_Simulations]]==
+
=Table of Contents=
Literally fake news.
 
  
== Why does 114.5 R = 100 rad?==
+
=Introduction=
This is why: [[Roentgen to Rad Conversion]]. Checkmate subsection ( ͡° ͜ʖ ͡°)
 
  
 +
=[[Radiation Dose Theory]]=
  
Note that 1Gy = 100 Rad
+
===[[Related Papers/Links]]===
  
 +
===[[Deposited Energy Simulations]]===
  
==[[Absorbed Dose Information]]==
+
===[[TriMev_Simulations]]===
  
=Apparatus=
+
===Why does 114.5 R = 100 rad?===
 +
This is why: [[Roentgen to Rad Conversion]].
  
==[[OSLs]]==
+
Note that 1Gy = 100 Rad
  
==Accelerators==
+
-> important in calibration of OSLs
  
===TriMeV Description===
+
===[[Absorbed Dose Information]]===
  
[[Cathode Profile]]
+
=Apparatus=
  
==Detectors==
+
===[[OSLs]]===
  
[[OSL Info]]
+
Get pictures from experiment for experimental setup, etc
  
===Nanodot Calibration===
+
==Nanodot Calibration==
  
 
====<math>^{137}\text{Cs Source}</math>====
 
====<math>^{137}\text{Cs Source}</math>====
  
 
[[Reproducibility with 137Cs]]
 
[[Reproducibility with 137Cs]]
 +
 +
[[Calibration Info]]
  
 
===[[First Board for Beam Profile]]===
 
===[[First Board for Beam Profile]]===
  
=Experimental Methods=
+
==Accelerators==
==[[Linac Run Plan April 2018, Dr. McNulty]]==
 
  
Nothing below is final and will be changed.
+
===25b Description===
  
=Date=
+
=[[Experimental Methods and Setup]]=
 +
===[[May 31st 2018 - 25b 0 degree port]]===
  
85 useable OSLs
+
=[[OSL Data Analysis]]=
  
Machine: 24b Linac
+
==[[OSL Reader]]==
  
Beam Energy: 8 MeV
+
-> Code used to create images and background subtraction
  
Rep Rate: Max (180Hz)?
 
  
:{| border="2" style="text-align:center;" |cellpadding="20" cellspacing="0
+
[[File:Pulse_v_Dose_Fit.png]]
|-
 
| Shot # ||Start Time  || End Time || Number of OSLs || Distance to end of beampipe || Beam Current || Aluminum Brick || Background Subtracted PMT Counts
 
|-
 
| 1 ||7am || 7:15am || 1 || 25cm || amps || Out ||
 
|-
 
| 2 ||7:20am || 7:35am || 1 || 25cm || amps || Out ||
 
|-
 
| 3 || 7:40am || 7:55am || 1 || 25cm || amps || Out ||
 
|-
 
| 4 || 8:00 || 8:20 || 1 || 25cm || amps || Out ||
 
|-
 
| 5 || ||  || 1 || 25cm || amps || Out ||
 
|-
 
| 6 || ||  || 1 || 25cm || amps || In ||
 
|-
 
| 7 || ||  || 1 || 25cm || amps || In ||
 
|-
 
| 8 || ||  || 1 || 25cm || amps || In ||
 
|-
 
| 9 || ||  || 1 || 25cm || amps || In ||
 
|-
 
| 10 || ||  || 1 || 25cm || amps || In ||
 
|-
 
| 11 ||  ||  || 10 || 25cm || amps || Out ||
 
|-
 
| 12 ||  ||  || 10 || 25cm || amps || Out ||
 
|-
 
| 13 ||  ||  || 10 || 25cm || amps || Out ||
 
|-
 
| 14 ||  ||  || 10 || 25cm || amps || Out ||
 
|-
 
| 15 ||  ||  || 10 || 25cm || amps || Out ||
 
|-
 
| 16 ||  ||  || 10 || 25cm || amps || In ||
 
|-
 
| 17 ||  ||  || 15 || 25cm || amps || In ||
 
|-
 
|}
 
  
=Data Analysis=
+
=Error Analysis=
Nothing to say here since good data analyzes itself, and my data is good af.
+
[[Forest Error Analysis for the Physical Sciences]]
  
==[[OSL Reader]]==
+
standard deviations and propagated errors
  
==[[TriMeV Shot Log]]==
+
error in OSL reader and OSLs (check manufacturer's paperwork)
 
 
=Error Analysis=
 
[[Forest Error Analysis for the Physical Sciences]]
 
  
 
=Conclusion=
 
=Conclusion=

Latest revision as of 00:49, 30 January 2019

Media:Thesis Dissertation-Manual.pdf

Writing

Calibration Info

OSLs

Experimental Methods

OSL Reader

Radiation Dose Theory

OSL Data Analysis

Title Page

Table of Contents

Introduction

Radiation Dose Theory

Related Papers/Links

Deposited Energy Simulations

TriMev_Simulations

Why does 114.5 R = 100 rad?

This is why: Roentgen to Rad Conversion.

Note that 1Gy = 100 Rad

-> important in calibration of OSLs

Absorbed Dose Information

Apparatus

OSLs

Get pictures from experiment for experimental setup, etc

Nanodot Calibration

[math]^{137}\text{Cs Source}[/math]

Reproducibility with 137Cs

Calibration Info

First Board for Beam Profile

Accelerators

25b Description

Experimental Methods and Setup

May 31st 2018 - 25b 0 degree port

OSL Data Analysis

OSL Reader

-> Code used to create images and background subtraction


Pulse v Dose Fit.png

Error Analysis

Forest Error Analysis for the Physical Sciences

standard deviations and propagated errors

error in OSL reader and OSLs (check manufacturer's paperwork)

Conclusion


User:Harpconn