Se170063 Pure Se Wide Gauss Window Expansion

From New IAC Wiki
Revision as of 11:31, 26 October 2017 by Brenleyt (talk | contribs)
Jump to navigation Jump to search

In this example I only weighted the histogram by the mass of the sample, which in the case of the pure selenium sample is 0.0971g.

400 <t< 640 sec 1100 < t < 1360 sec 1875 < t < 2150 2650 < t < 2930 sec 3400 < t < 3690 sec 4120 < t < 4400 sec 4840 < t < 5130 sec
Original Window Counts 564700 536100 497100 432200 380500 319900 289400
Original Window Background (Integrated) 85711 86719 78500.2 73399.5 76327.6 61106.5 57459.7
Original Window Difference 478989 449381 418599.8 358800.5 304172.4 243572.4 231940.3
Expanded Window Counts 587300 558100 517500 451400 398700 336000 304500
Expanded Window Background 108563 108152 98915.2 92183.5 93245 77423.5 72660.2
Expanded Window Difference 478737 449948 418584.8 359216.5 305455 258576.5 231839.8
Error in counts 252* 567 15* 416 1282.6 15004.1 100.5 *
.dat file entry 7.598793988 +/- 0.0005261081152 7.454944728 +/- 0.0012617356 7.327899514 +/- 0.0000358337 7.1557322 +/- 0.0011594187 6.955469002 +/- 0.0042166876 6.768379905 +/- 0.0616001649 6.684354367 +/- 0.0004333011