Imaging System for Emittance Measurement of IAC Medical Linac

Abstract

A 16 MeV S-band linac at the Idaho Accelerator Center was recently reconfigured to produce a secondary beam of positrons using 100 mA peak electron currents and a Tungsten converter. The transverse electron beam emittance was measured to optimize a quad triplet system positrons collection system escaping on the downstream side of the Tungsten converter. In 2011, we developed an optical transmission radiation (OTR) based beam imaging system coupled to a digital CCD camera using three optical lens to measure the emittance. In this paper, we describe the OTR beam imaging system and its performance.

Introduction

We used 3 lenses to collect OTR light from Al target. To improve image quality, 2 inch diameter lenses were selected. They have focal length of 100 mm, 500 mm and 50 mm, they were called collector lens, fine tune lens and main focus lens respectively. Collector lens has the middle focal length, collects most of the light from the source. Fine tune lens has the biggest focal length, act as fine tune of magnification. Main focus lens: has the smallest focal length, has biggest focusing strength, so act as main focus of light and focuses light to CCD.

Experiment Setup

Camera cage system was located below the OTR target. There are 3 lenses used to focus lights from target to the CCD camera. Target can be pushed into or taken out of the beamline by the actuator at the top.


Fig. HRRL beamline: Optical cage system to focus OTR lights on CCD camera.
Fig. HRRL beamline: Optical lenses lay out for optical cage system.