Difference between revisions of "PositronTargetWorkByChrissJackson"

From New IAC Wiki
Jump to navigation Jump to search
 
(20 intermediate revisions by 2 users not shown)
Line 40: Line 40:
  
  
Dimensions for the target chamber box.
+
Dimensions for the target chamber box. Measurements in inches. updated 11 May 2012. Holes for tubing still missing, need to measure.
  
[[File:targetbox.jpg | 200 px]]
+
{| border="1" cellpadding="20" cellspacing="0"
 +
|-
 +
|[[File:Target_box-bottom.jpg | 100 px]]||[[File:Target_box-front.jpg | 100 px]] || [[File:Target_box-left.jpg | 100 px]]|| [[File:Target_box-iso.jpg | 100 px]]
 +
|-
 +
| Bottom view || Front View || Left View || Isometric View
 +
|}
  
  The resolution in the above image makes it too dificult to read the numbersSee if you can upload a PDF version.
+
 
 +
==ports==
 +
 
 +
 
 +
 
 +
  {| border="1"  |cellpadding="20" cellspacing="0
 +
|-
 +
| Parts    || Quantity || Items connecting to Target Chamber
 +
|-
 +
|  10 - pin wiring feedthrough || 1 || [http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=9132004 Feedthrough] 
 +
|-
 +
|  cooling lines  ||  2 || [http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=611005 Cooling Hoses]
 +
|-
 +
| IR optical window  || 2  || [http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=9712007  Optical Window]
 +
|-
 +
| Beam line || 2  || [http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=100021  Flange]
 +
|-
 +
| Ion Pump || 1  || [http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=100021 Flange]
 +
|-
 +
| Roughing Pump || 1  ||
 +
|}
 +
 
 +
 
 +
 
 +
1.) Lid with a lip that bolts on.
 +
 
 +
2.) bolt pattern on the bottom for the motor mounts
 +
 
 +
3.) find cooling lines for inside the box
 +
 
 +
4.) Find elbows for the rotary unions.
 +
 
 +
.
 +
.
 +
.
 +
.
 +
100.) Design a target mounting system
  
 
=Equipment=
 
=Equipment=
Line 55: Line 96:
  
 
==Feedthroughs==
 
==Feedthroughs==
 +
 +
[[File:liquid_nitro_tubing.gif]]
 +
 +
A: 5.88
 +
B: 3.00
 +
C: 4.25
 +
D: 4.63
 +
 +
http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=611005
  
 
=Performance tests=
 
=Performance tests=

Latest revision as of 17:59, 15 May 2012

Chriss Jackson's Positron Target development logbook
Goal
Construct a Tungsten target and vacuum enclosure to be used for generating positrons using an incident electron beam.

Geometry

Tungsten Disks

Dimensions are in cm

HRRL PosTargetDesign 4-20-11.png

http://www.alibaba.com/product-gs/346924116/Tungsten_Disk_With_Screw.html


http://www.zlxtech.com.cn/products.asp?productcode=7401000404

http://www.cleveland-tungsten.com/


If the motor has a radius of 2.5" and I want to shield the motor from the beam using 2" of Pb and the beam is about 1" in diameter then I want a Tungsten disk that is

5.21" in radius = 13.25 cm in radius ~ 30 cm in diameter


Target Chamber design

Latest Design From empire and Sadiq's measurement of the available space


EmpMagHRRLPositronTargetChamberDrw 9-20-11.png HRRLPositronTargetSpace 10-5-11.png HRRLPositronTargetCoupler 10-5-11.png HRRLPositronTargetHub 10-5-11.png
Target motor Design Available beam line space Motor axle coupling to rotary union Hub and spline to attache targets


Dimensions for the target chamber box. Measurements in inches. updated 11 May 2012. Holes for tubing still missing, need to measure.

Target box-bottom.jpg Target box-front.jpg Target box-left.jpg Target box-iso.jpg
Bottom view Front View Left View Isometric View


ports

Parts Quantity Items connecting to Target Chamber
10 - pin wiring feedthrough 1 Feedthrough
cooling lines 2 Cooling Hoses
IR optical window 2 Optical Window
Beam line 2 Flange
Ion Pump 1 Flange
Roughing Pump 1


1.) Lid with a lip that bolts on.

2.) bolt pattern on the bottom for the motor mounts

3.) find cooling lines for inside the box

4.) Find elbows for the rotary unions.

. . . . 100.) Design a target mounting system

Equipment

Motor

Controller

Vacuum Chamber

Feedthroughs

Liquid nitro tubing.gif

A: 5.88 B: 3.00 C: 4.25 D: 4.63

http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=611005

Performance tests

Heat load calculation

HRRL_Positron_Rotating_W_Target