PbF2 CrystalNumber18
Jump to navigation
Jump to search
Below are the resulting transparency measurements for PbF2 block # 18
12/4/07
- Accelerator Settings
| beam energy | 20 MeV |
| Rep Rate: | 30 Hz |
| I_peak: | 60 mA/pulse |
| pulse width: | 0.1 s (100 ns) |
| beam start: | 10:42 |
| beam stop: | 12:42 |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt ns
- Dose rate measurements (@1255 hours)
| -radiation | 500 uR/hr |
| -radiation: | 500 uR/hr |
- Transparency Measurements (@1525 hours)
12/5/07
- Transparency measurement (1235)
- Accelerator Settings
| beam energy | 20 MeV |
| Rep Rate: | 30 Hz |
| I_peak: | 60 mA/pulse |
| pulse width: | 0.1 s (100 ns) |
| beam start: | 12:54 |
| beam stop: | 14:55 |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt ns
- Dose rate measurements (@1457 hours)
| -radiation | 5 mR/hr |
| -radiation: | 10 mR/hr |