Difference between revisions of "Paste painting procedure"

From New IAC Wiki
Jump to navigation Jump to search
 
(92 intermediate revisions by one other user not shown)
Line 1: Line 1:
=Safety Conditions=
+
=Purpose=
Before open the paste please read SDS [[File:ED7100_OSHA_MSDS.pdf]] for the paste. Be sure that the following are available:
 
  
1- Gloves
+
This document description the application proceedures to safely apply the ED-7100 carbon paste.
 +
[[File:ED7100_Series_paste.pdf]]
  
2- Mask to cover the nose.
+
=Requirements for safe handling=
 +
Before opening the paste please read  the ED-7100 Safety Data Sheet located at
  
3- sack of sand.
+
:http://wiki.iac.isu.edu/index.php/File:ED7100_OSHA_MSDS.pdf
  
Be sure that you are working under the hood.
+
Be sure that the following are available:
  
 +
;Ventilation:
 +
An externally venting fume hood is recommended when working with this paste or a work area with very good ventilation.
  
[[Neutron_TGEM_Detector_Abdel#7.2F31.2F2009]]
+
;Poor Ventilation area:
 +
Wear a well fitted NIOSH approved or industrial type canister mask.
 +
 
 +
:http://www1.mscdirect.com/CGI/NNSRIT?PMPXNO=1651332&PMT4NO=0
 +
 
 +
:http://www1.mscdirect.com/Disposable-Respirators-And-Masks/Respiratory-Protection/Safety/s0000002069.HTML
 +
 
 +
 
 +
;The following are required for applying the paste:
 +
 
 +
# Gloves,goggles.
 +
#suitable protection clothes.
 +
# sack of sand or absorber for cleaning the area.
 +
 
 +
=Paste Application Procedure=
 +
; a- Review the "Requirements for Safe Handling" section preceding this one before using the paste.[http://wiki.iac.isu.edu/index.php/Paste_painting_procedure#Requirements_for_safe_handling]
 +
 
 +
; b- Equipment And Tools:
 +
#ED-7100 paste
 +
# isobutanol for cleaning,
 +
#CLR A/F lens blue frame revolution dust goggles
 +
#27"WD 36"L vinyl clear ansell chem-resist apron
 +
#35"WD 45"L neoprene Black ansell chem-resist apron
 +
#8511 N90 3M particulate respirator
 +
#Nitrile disposal gloves
 +
 
 +
 
 +
; d- Application steps:
 +
 
 +
#put on mask and apron (use goggles if spraying paste using printer)
 +
#establish a work area under the ventilatin hood in the Laboratory for Detector Science#Add the paste to copper plate.(using a brush or a semi-mechanical printer)
 +
#mix paste (if reducing is needed) under the hood for sufficient ventilation
 +
#use applicator to smear paste on pc-board
 +
#Clean the paste residues using isobutanol cleaner.
 +
# Cure for 1 - 2h 30min. at 150 - 165 degrees Celsius.(Contact the company for IR-curing)
 +
 
 +
 
 +
Back to the main page [http://wiki.iac.isu.edu/index.php/Neutron_TGEM_Detector_Abdel#10.2F27.2F09_.28Paste_painting_procedure.29]

Latest revision as of 15:55, 5 March 2012

Purpose

This document description the application proceedures to safely apply the ED-7100 carbon paste. File:ED7100 Series paste.pdf

Requirements for safe handling

Before opening the paste please read the ED-7100 Safety Data Sheet located at

http://wiki.iac.isu.edu/index.php/File:ED7100_OSHA_MSDS.pdf

Be sure that the following are available:

Ventilation

An externally venting fume hood is recommended when working with this paste or a work area with very good ventilation.

Poor Ventilation area

Wear a well fitted NIOSH approved or industrial type canister mask.

http://www1.mscdirect.com/CGI/NNSRIT?PMPXNO=1651332&PMT4NO=0
http://www1.mscdirect.com/Disposable-Respirators-And-Masks/Respiratory-Protection/Safety/s0000002069.HTML


The following are required for applying the paste
  1. Gloves,goggles.
  2. suitable protection clothes.
  3. sack of sand or absorber for cleaning the area.

Paste Application Procedure

a- Review the "Requirements for Safe Handling" section preceding this one before using the paste.[1]
b- Equipment And Tools
  1. ED-7100 paste
  2. isobutanol for cleaning,
  3. CLR A/F lens blue frame revolution dust goggles
  4. 27"WD 36"L vinyl clear ansell chem-resist apron
  5. 35"WD 45"L neoprene Black ansell chem-resist apron
  6. 8511 N90 3M particulate respirator
  7. Nitrile disposal gloves


d- Application steps
  1. put on mask and apron (use goggles if spraying paste using printer)
  2. establish a work area under the ventilatin hood in the Laboratory for Detector Science#Add the paste to copper plate.(using a brush or a semi-mechanical printer)
  3. mix paste (if reducing is needed) under the hood for sufficient ventilation
  4. use applicator to smear paste on pc-board
  5. Clean the paste residues using isobutanol cleaner.
  6. Cure for 1 - 2h 30min. at 150 - 165 degrees Celsius.(Contact the company for IR-curing)


Back to the main page [2]