Line 16: Line 16:
 
[[Image:gaussian1.jpg]]<br>
 
[[Image:gaussian1.jpg]]<br>
  
<math>\sigma</math>=
+
<math>\sigma</math>=0.42+/-0.011 keV<br>
 
[[Image:gaussian2.jpg]]<br>
 
[[Image:gaussian2.jpg]]<br>
 
[[Image:gaussian3.jpg]]<br>
 
[[Image:gaussian3.jpg]]<br>

Revision as of 05:44, 26 June 2007

Data Run:
Paraffin wax layer of thickness 12.6 cm was used as a neutron attenuator and for cosmic rays lead of thickness 10 cm on sides of
HpGe detector. Total time of the run was ~9 hours. Total number of counts: 11,157,085. The source was Cf-252 (activity 60μCi)

1. Energy region 0-1000 keV
Jun25 Cf paraffin1.jpg

2. Energy region 1000-2000 keV
Jun25 Cf paraffin2.jpg

3. Energy region 2000-3000 keV
Jun25 Cf paraffin3.jpg


Gaussian1.jpg

[math]\sigma[/math]=0.42+/-0.011 keV
Gaussian2.jpg
Gaussian3.jpg