Difference between revisions of "G4Beamline PbBi"

From New IAC Wiki
Jump to navigation Jump to search
Line 48: Line 48:
 
| 2.5    ||  || 2062
 
| 2.5    ||  || 2062
 
|-
 
|-
| 3|| <math>\pm</math> 13|| 1986
+
| 3|| 1920 <math>\pm</math> 13|| 1986
 
|-
 
|-
 
| 3.5||  || 1938
 
| 3.5||  || 1938

Revision as of 20:17, 1 May 2015

Development of a Positron source using a PbBi converter and a Solenoid

Converter target properties

Definition of Lead Bismuth


1cm diameter target 2 mm thick PbBi

0.5 Tesla solenoid

G4BeamLine and MCNPX

Target thickness optimization

PbBi_THickness_GaussBeam

2mm thick PbBi, 10 MeV, 1 cm cylindrical incident electron distribution

G4beamline pencil beam 10 cm radius

beam ellipse particle=e- nEvents=1000000 beamZ=0.0 beamX=0. beamY=0. \
        sigmaX=10.0 sigmaY=10.0 sigmaXp=0.000 sigmaYp=0.000 \
      meanMomentum=10. sigmaE=0. maxR=10.

Incident Electron spatial distribution and energy

PbBi 5-1-15 X-Yposition.pngPbBi 5-1-15 Ein.png

Positron and Electron Momentum after the converter

PbBi 5-1-15 Ppositron.pngPbBi 5-1-15 Pelectron.png

PbBi Thickness (mm) #positrons/million electrons (G4Beamline) #positrons/million electrons (MCNPX)
1 1091
1.5 1728
2 1902,1921,1886,1967,1922=1920[math]\pm[/math] 30 1984
2.5 2062
3 1920 [math]\pm[/math] 13 1986
3.5 1938
4 [math]\pm[/math] 39 1858
5 1646
6 [math] \pm[/math] 37 1541
10 1216


Layout.png

ElectronTracks.pngPhotonTracks.png

ElectronEnergy.pngPhotonEnergy.png

2mm thick PbBi, 10 MeV, point source

G4beamline pencil beam 10 cm radius

beam ellipse particle=e- nEvents=1000000 beamZ=0.0 beamX=0. beamY=0. \
        sigmaX=10.0 sigmaY=10.0 sigmaXp=0.000 sigmaYp=0.000 \
      meanMomentum=10. sigmaE=0. maxR=10.
PbBi Thickness (mm) #positrons/million electrons (G4Beamline) #positrons/million electrons (MCNPX)
1 1091
1.5 1728
2 1902[math]\pm[/math] 43 1984
2.5 2062
3 [math]\pm[/math] 13 1986
3.5 1938
4 [math]\pm[/math] 39 1858
5 1646
6 [math] \pm[/math] 37 1541
10 1216

Solenoid

Positrons#Simulations