Difference between revisions of "CHIPS IAC Run 5-29-08"

From New IAC Wiki
Jump to navigation Jump to search
Line 23: Line 23:
 
|46|| NaI046.mpa || IN || IN || Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, 116 <math>\pm</math> 15 counts at 500 keV, Live=929 seconds
 
|46|| NaI046.mpa || IN || IN || Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, 116 <math>\pm</math> 15 counts at 500 keV, Live=929 seconds
 
|-
 
|-
|47|| NaI047.mpa || IN || Out || Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, 53 <math>\pm</math> 9 counts at 500 keV, Live=607 seconds, (116/53 <math>\times</math> 607/929 =  1.4
+
|47|| NaI047.mpa || IN || Out || Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, 53 <math>\pm</math> 9 counts at 500 keV, Live=607 seconds, (Tant IN/Out ratio =116/53 <math>\times</math> 607/929 =  1.4)
 
|-
 
|-
 
|48|| NaI048.mpa || IN || Out|| Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, 90 <math>\pm</math> 11 counts at 500 keV, Live=600 seconds, ignore NaI (cable not plugged into scope)
 
|48|| NaI048.mpa || IN || Out|| Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, 90 <math>\pm</math> 11 counts at 500 keV, Live=600 seconds, ignore NaI (cable not plugged into scope)
 
|-
 
|-
|49|| NaI049.mpa || IN || In|| Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate,  113<math>\pm</math> 12 counts at 500 keV, Live=634 seconds,plugged NaI cable back into scope in middle of run. (113/90 = 1.26 )
+
|49|| NaI049.mpa || IN || In|| Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate,  113<math>\pm</math> 12 counts at 500 keV, Live=634 seconds,plugged NaI cable back into scope in middle of run. ((Tant IN/Out ratio =113/90 = 1.26 )
 
|-
 
|-
 
|52|| NaI052.mpa || IN || In|| Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, (1202 set to 15.7 kV.  This is the PS for the pulse forming network.) 28<math>\pm</math> 8 counts at 500 keV, Live=600 seconds.
 
|52|| NaI052.mpa || IN || In|| Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, (1202 set to 15.7 kV.  This is the PS for the pulse forming network.) 28<math>\pm</math> 8 counts at 500 keV, Live=600 seconds.

Revision as of 14:08, 29 May 2008

Calibration

Run # MPA file name Description
40 NaI040.mpa Na-22 source in front of HpGe and Co-60 on top of NaI detector
41 NaI019.mpa Co-60 source in front of HpGe and Na-22 on top of NaI detector

Last Dipole Sweepl

Tune 10 Mev onto Tungsten and 4 MeV into Cell


Run # MPA file name W Ta Description
45 NaI045.mpa IN IN Dipole at 2 MeV (0.78 on Pot), 60 Hz rep rate
46 NaI046.mpa IN IN Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, 116 [math]\pm[/math] 15 counts at 500 keV, Live=929 seconds
47 NaI047.mpa IN Out Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, 53 [math]\pm[/math] 9 counts at 500 keV, Live=607 seconds, (Tant IN/Out ratio =116/53 [math]\times[/math] 607/929 = 1.4)
48 NaI048.mpa IN Out Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, 90 [math]\pm[/math] 11 counts at 500 keV, Live=600 seconds, ignore NaI (cable not plugged into scope)
49 NaI049.mpa IN In Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, 113[math]\pm[/math] 12 counts at 500 keV, Live=634 seconds,plugged NaI cable back into scope in middle of run. ((Tant IN/Out ratio =113/90 = 1.26 )
52 NaI052.mpa IN In Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, (1202 set to 15.7 kV. This is the PS for the pulse forming network.) 28[math]\pm[/math] 8 counts at 500 keV, Live=600 seconds.

Go Back