Using CED to verify the angle and wire correlation,
Zooming in on the view paralell to the direction of the wires in ced, we can examine the wire corresponding theta angle in the drift chamber.
Coordinates(cm) | Layer 1 | Layer 2 | Layer 3 | Layer 4 | Layer 5 | Layer 6 |
---|---|---|---|---|---|---|
x | 20.42 | 21.51 | 21.39 | 22.49 | 22.37 | 23.47 |
y | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
z | 243.41 | 244.18 | 245.51 | 246.28 | 247.62 | 248.38 |
Coordinates(cm) | Layer 1 | Layer 2 | Layer 3 | Layer 4 | Layer 5 | Layer 6 |
---|---|---|---|---|---|---|
x | 21.64 | 22.73 | 22.61 | 23.71 | 23.58 | 24.69 |
y | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
z | 242.86 | 243.62 | 244.94 | 245.71 | 247.05 | 247.81 |
Corresponding theta angles can be found for other wires, in Region 1, Superlayers 1 and 2.
Wire Number | Layer 1 | Layer 2 | Layer 3 | Layer 4 | Layer 5 | Layer 6 |
---|---|---|---|---|---|---|
1 | 4.79 | 5.03 | 4.98 | 5.22 | 5.16 | 5.40 |
2 | 5.09 | 5.33 | 5.27 | 5.51 | 5.45 | 5.69 |
77 | 29.46 | 29.60 | 29.41 | 29.55 | 29.37 | 29.51 |
78 | 29.79 | 29.93 | 29.74 | 29.88 | 29.69 | 29.83 |
79 | 30.12 | 30.26 | 30.07 | 30.21 | 30.02 | 30.16 |
110 | 40.19 | 40.28 | 40.05 | 40.13 | 39.91 | 39.99 |
111 | 40.51 | 40.59 | 40.36 | 40.44 | 40.21 | 40.29 |
112 | 40.82 | 40.90 | 40.67 | 40.75 | 40.52 | 40.60 |
May 2017:CED Verification of DC Angle Theta and Wire Correspondance
Using CED to verify the angle and wire correlation,
Zooming in on the view paralell to the direction of the wires in ced, we can examine the wire corresponding theta angle in the drift chamber.
Coordinates(cm) | Layer 1 | Layer 2 | Layer 3 | Layer 4 | Layer 5 | Layer 6 |
---|---|---|---|---|---|---|
x | 21.01 | 22.11 | 21.98 | 23.08 | 22.95 | 24.07 |
y | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
z | 243.13 | 244.89 | 245.23 | 245.99 | 247.33 | 248.12 |
Coordinates(cm) | Layer 1 | Layer 2 | Layer 3 | Layer 4 | Layer 5 | Layer 6 |
---|---|---|---|---|---|---|
x | 22.23 | 23.32 | 23.20 | 24.29 | 24.17 | 25.29 |
y | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
z | 242.55 | 243.32 | 244.68 | 245.42 | 246.75 | 247.55 |
Using the expressions calculated for x and z, as well as the angle theta with respect to the beam line to the wire
Wire Number | Layer 1 |
---|---|
1 | 5.23 |
2 | 5.53 |
77 | 29.80 |
78 | 30.13 |
79 | 30.46 |
110 | 40.45 |
111 | 40.76 |