11-11-2016

From New IAC Wiki
Jump to navigation Jump to search

Runlist

Horizontal accelerator side collimator 7 mm, horizontal cell side 19 mm. 3 in of Pb on D30 & D330, 2 in of Pb on upstream side of D210, wax in front of Pb on wall downstream of beam dump

Run # D90 n Rate (Counts/pulse)E-3 Target Configuration
5446 0.53 Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 50 mV, D30 @ -1450V and all other detectors at -1500 V ,
5447 0.34 Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 70 mV, D30 @ -1450V and all other detectors at -1500 V ,
5448 - Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 30 mV, D30 @ -1450V and all other detectors at -1500 V ,
5449 - Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V ,
5450 - Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 60 mV, D30 @ -1450V and all other detectors at -1500 V ,
5451 - MT 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 60 mV, D30 @ -1450V and all other detectors at -1500 V ,
5452 - MT 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V ,
5453 - Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V , removed battleship steel (4" wide [beamleft/right] and 30 inches high [beam up/down], now its 9" wide and 13" high, green poly is on the bottom to prop up the steel
5454 - Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V , green poly is on the bottom to prop up the steel, steel blinder is 6" wide
5455 - Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V , green poly is on the bottom to prop up the steel, steel blinder is 4" wide
5456 - Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V , green poly is on the bottom to prop up the steel, steel blinder is 2" wide
5457 - Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V , green poly is on the bottom to prop up the steel, steel blinder is 0" wide (steel blinders are closed)
5458 - Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V , green poly is on the bottom to prop up the steel, steel blinder is 8" wide (steel blinders are closed)
5459 - Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V , green poly is on the bottom to prop up the steel, steel blinder is 7" wide (steel blinders are closed)
5460 - Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V , green poly is on the bottom to prop up the steel, steel blinder is 5" wide (steel blinders are closed), poly around Th target, front of blinder was 21" away from front of Alumionum brick wall, All bricks are 8" long so battle ship steel blinders began 29" away from rear wall, R5460BlinderPic.png
5461 - Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V , No beam dump removed poly Th target,
5462 - Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V , No beam dump removed poly' Th target, Added 2" thick Aluminum hardener downstream of sweep magnet

Summary

ToF spectrum for 30, 40 50 and 70 mV thresholds.

ToFVSThresh(Nov11).png


Blinder width study

Blinder as a photon source

Blinders 0INto4IN.png


Blinder blocking back wall source

Blinders 5INto9IN.png

With/Without Blinder

WithWithOutBlinders 11-11-16.png

With/Without Hardener

WithWithOutHardener 11-11-16.png WithWithOutHardener Rates 11-11-16.png