04-22-2015

From New IAC Wiki
Jump to navigation Jump to search

Pu-Be source test

PMT detector #4 HV at -1000 Volts

Pu-Be 18 gram source# M1197

  • Run 4546 had a discriminator threshold set to 80 mV and the terminators were out. Cosmic rays test.
Region 1 Region 2
Fake stop Second hit
  • Run 4547 had a discriminator threshold set to 80 mV and the terminators were out. DAQ rate is 100 Hz. Pu-Be source in.
Region 1 Region 2
Fake stop Second hit
  • Run 4548 had a discriminator threshold set to 80 mV and the terminators were in. DAQ rate is 100 Hz. Pu-Be source in.
Region 1 Region 2
Fake stop Second hit
  • Run 4549 had a discriminator threshold set to 40 mV and the terminators were in. DAQ rate is 2800 Hz. Pu-Be source in.
Region 1 Region 2
Fake stop Second hit
  • Run 4550 had a discriminator threshold set to 40 mV and the terminators were out. DAQ rate is 2800 Hz. Pu-Be source in.
Region 1 Region 2
Fake stop Second hit
  • Run 4551 had a discriminator threshold set to 40 mV and the terminators were out. DAQ rate is 500 Hz. Pu-Be source in, moved away from the detector by 26".
Region 1 Region 2
Fake stop Second hit
  • Run 4552 had a discriminator threshold set to 40 mV and the terminators were in. DAQ rate is 500 Hz. Pu-Be source in, moved away from the detector by 26".
Region 1 Region 2
Fake stop Second hit
  • Run 4553 had a discriminator threshold set to 20 mV and the terminators were in. DAQ rate is 1850 Hz. Pu-Be source in, moved away from the detector by 26".
Region 1 Region 2
Fake stop Second hit
  • Run 4554 had a discriminator threshold set to 20 mV and the terminators were in. DAQ rate is 625 Hz. Pu-Be source in, moved away from the detector by 52".
Region 1 Region 2
Fake stop Second hit
  • Run 4555 had a discriminator threshold set to 20 mV and the terminators were out. DAQ rate is 650 Hz. Pu-Be source in, moved away from the detector by 52".
Region 1 Region 2
Fake stop Second hit
  • Run 4556 had a discriminator threshold set to 10 mV and the terminators were out. DAQ rate is 1400 Hz. Pu-Be source in, moved away from the detector by 52".
Region 1 Region 2
Fake stop Second hit
  • Run 4557 had a discriminator threshold set to 10 mV and the terminators were in. DAQ rate is 1400 Hz. Pu-B source in, moved away from the detector by 52".
Region 1 Region 2
Fake stop Second hit


PMT detector #4 HV at -1400 Volts
  • Run 4558 had a discriminator threshold set to 10 mV and the terminators were in. DAQ rate is 4670 Hz. Pu-Be source in, moved away from the detector by 52".
Region 1 Region 2
Fake stop Second hit
  • Run 4559 had a discriminator threshold set to 10 mV and the terminators were in. DAQ rate is 2700 Hz. Pu-Be source in, moved away from the detector by 91".
Region 1 Region 2
Fake stop Second hit
  • Run 4560 had a discriminator threshold set to 10 mV and the terminators were out. DAQ rate is 2700 Hz. Pu-Be source in, moved away from the detector by 91".
Region 1 Region 2
Fake stop Second hit
  • Run 4561 had a discriminator threshold set to 10 mV and the terminators were out. DAQ rate is 200 Hz. Cosmic rays test.
Region 1 Region 2
Fake stop Second hit
1.8 g Pu-Be source should be used next time