CHIPS IAC Run 5-29-08
Calibration
| Run # | MPA file name | Description |
| 40 | NaI040.mpa | Na-22 source in front of HpGe and Co-60 on top of NaI detector |
| 41 | NaI019.mpa | Co-60 source in front of HpGe and Na-22 on top of NaI detector |
Last Dipole Sweep
Tune 10 Mev onto Tungsten and 4 MeV into Cell
We put in two thin pieces (thickness ~1/4" each) making a ~1/2" of lead angled at ~30 degrees wrt vertical between the NaI detector and the collimator to cut down on low-energy (< 200 keV) photons.
| Run # | MPA file name | W | Ta | Description |
| 45 | NaI045.mpa | IN | IN | Dipole at 2 MeV (0.78 on Pot), 60 Hz rep rate |
| 46 | NaI046.mpa | IN | IN | Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, 116 15 counts at 500 keV, Live=929 seconds |
| 47 | NaI047.mpa | IN | Out | Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, 53 9 counts at 500 keV, Live=607 seconds, (Tant IN/Out ratio =116/53 607/929 = 1.4) |
| 48 | NaI048.mpa | IN | Out | Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, 90 11 counts at 500 keV, Live=600 seconds, ignore NaI (cable not plugged into scope) |
| 49 | NaI049.mpa | IN | In | Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, 113 12 counts at 500 keV, Live=634 seconds,plugged NaI cable back into scope in middle of run. ((Tant IN/Out ratio =113/90 = 1.26 ) |
Accelerator Gun problem (ground wire shielding was worn away and creating path for short)
Restore tune with settings below.:
| Device | setting |
| RS1 | 0+ |
| RS2 | 0- |
| FS1 | 0+ |
| FS2 | 0- |
| 0Q1 | -0.20 |
| 0Q2 | +2.86 |
| 45Q1 | -0.004 |
| 45Q2 | +2.24 |
| L90Q1 | -1.33 |
| L90Q2 | +2.42 |
| Bend1 | 3.5 |
| Bend2 | 0.86 |
| Gun HV | 13 kV |
| Grid | 2.31 |
| 802 | 16 kV |
| SOL1 | 0.39 |
| SOL2 | 0.40 |
| Run # | MPA file name | W | Ta | Description |
| 56 | NaI056.mpa | IN | In | Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 48 8 counts at 500 keV, Live=600 seconds, grid = 1.64, Gun = 3 kV. |