CHIPS IAC Run 5-29-08
Calibration
| Run # | MPA file name | Description |
| 40 | NaI040.mpa | Na-22 source in front of HpGe and Co-60 on top of NaI detector |
| 41 | NaI019.mpa | Co-60 source in front of HpGe and Na-22 on top of NaI detector |
Last Dipole Sweepl
Tune 10 Mev onto Tungsten and 4 MeV into Cell
| Run # | MPA file name | W | Ta | Description |
| 45 | NaI045.mpa | IN | IN | Dipole at 2 MeV (0.78 on Pot), 60 Hz rep rate |
| 46 | NaI046.mpa | IN | IN | Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, 116 15 counts at 500 keV, Live=929 seconds |
| 47 | NaI047.mpa | IN | Out | Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, 53 9 counts at 500 keV, Live=607 seconds, (Tant IN/Out ratio =116/53 607/929 = 1.4) |
| 48 | NaI048.mpa | IN | Out | Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, 90 11 counts at 500 keV, Live=600 seconds, ignore NaI (cable not plugged into scope) |
| 49 | NaI049.mpa | IN | In | Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, 113 12 counts at 500 keV, Live=634 seconds,plugged NaI cable back into scope in middle of run. ((Tant IN/Out ratio =113/90 = 1.26 ) |
| 52 | NaI052.mpa | IN | In | Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, (1202 set to 15.7 kV. This is the PS for the pulse forming network.) 28 8 counts at 500 keV, Live=600 seconds. |