G4Beamline PbBi
Development of a Positron source using a PbBi converter and a Solenoid
Converter target properties
Definition of Lead Bismuth
1cm diameter target
2 mm thick PbBi
0.5 Tesla solenoid
G4BeamLine and MCNPX
Target thickness optimization
PbBi_THickness_GaussBeam First simple test is to send 1 million, 10 MeV electrons towards a PbBi target and count how many positrons leave the downstream side
The Random number seed is set by Time in G4beamline to use a different set of pseudo random numbers each time it is run
The G4Beamlin incident electron beam has the following properties
beam gaussian particle=e- nEvents=1000000 beamZ=0.0 sigmaX=1.0 sigmaY=1.0 sigmaXp=0.100 sigmaYp=0.100 meanMomentum=10.0 sigmaP=4.0 meanT=0.0 sigmaT=0.0
PbBi Thickness (mm) | #positrons/million electrons (G4Beamline) | #positrons/million electrons (MCNPX) |
1 | 960,874, 916,934,897=916 +/- 33 | 1091 |
1.5 | 1508 | 1728 |
2 | 1963,1919,1880,1877,1970 = 1902 | 431984 |
2.5 | 1997 | 2062 |
3 | 2233,2250, 2251,2226 , 2222=2236 | 131986 |
3.5 | 2193 | 1938 |
4 | 2184,2156,2089,2173,2181=2157 | 391858 |
5 | 2042 | 1646 |
6 | 1851, 1932, 1857, 1896,1924 = 1892 | 371541 |
10 | 1480,1488 | 1216 |
Comparison of G4Beamline and MCNPX
Energy Distribution
Angular distribution of positrons
I was unable to do anything other than a gaussian beam right now, I will try to do one later
For now I have a gaussian with an 8mm RMS and 10 MeV incident electrons as shown below.
The positron and electron momentum distributions after the PbBi converter are shown below
A comma delimited text file with the above events in the format of
x,y,z,Px,Py,Pz
in units of cm for distance and MeV for momentum is located at
for positrons
http://www2.cose.isu.edu/~foretony/Positrons_2mm10MeV.dat
and
http://www2.cose.isu.edu/~foretony/Electrons_2mm10MeV.dat
for electrons
For now I have a gaussian with an 1mm RMS and 10 MeV incident electrons as shown below.
The positron and electron momentum distributions after the PbBi converter are shown below
A comma delimited text file with the above events in the format of
x,y,z,Px,Py,Pz
in units of cm for distance and MeV for momentum is located at
for positrons
http://www2.cose.isu.edu/~foretony/Positrons_2mm10MeVDelta.dat
and
http://www2.cose.isu.edu/~foretony/Electrons_2mm10MeVDelta.dat
for electrons
2mm thick PbBi, 10 MeV, 1 cm cylindrical incident electron distribution
G4beamline pencil beam 10 cm radius
beam ellipse particle=e- nEvents=1000000 beamZ=0.0 beamX=0. beamY=0. \ sigmaX=10.0 sigmaY=10.0 sigmaXp=0.000 sigmaYp=0.000 \ meanMomentum=10. sigmaE=0. maxR=10.
PbBi Thickness (mm) | #positrons/million electrons (G4Beamline) | #positrons/million electrons (MCNPX) |
1 | 1091 | |
1.5 | 1728 | |
2 | 1902 | 431984 |
2.5 | 2062 | |
3 | 13 | 1986 |
3.5 | 1938 | |
4 | 39 | 1858 |
5 | 1646 | |
6 | 37 | 1541 |
10 | 1216 |
2mm thick PbBi, 10 MeV, point source
G4beamline pencil beam 10 cm radius
beam ellipse particle=e- nEvents=1000000 beamZ=0.0 beamX=0. beamY=0. \ sigmaX=10.0 sigmaY=10.0 sigmaXp=0.000 sigmaYp=0.000 \ meanMomentum=10. sigmaE=0. maxR=10.
PbBi Thickness (mm) | #positrons/million electrons (G4Beamline) | #positrons/million electrons (MCNPX) |
1 | 1091 | |
1.5 | 1728 | |
2 | 1902 | 431984 |
2.5 | 2062 | |
3 | 13 | 1986 |
3.5 | 1938 | |
4 | 39 | 1858 |
5 | 1646 | |
6 | 37 | 1541 |
10 | 1216 |