TF IsotopeTracers4Cracks

From New IAC Wiki
Jump to navigation Jump to search

Definition of Shale

Shale was assumed to have the chemical composition of

[math]\mbox{Al}_2\mbox{Si}_2\mbox{O}_5(\mbox{OH})_4[/math]

and a density of 2.6 g/[math]\mbox{cm}^3[/math]


G4Element* O = new G4Element("Oxygen"  , "O", z=8., a= 16.00*g/mole);
G4Element* Al = new G4Element("Aluminum"  , "Al", z=13., a= 26.98*g/mole);
G4Element* Si = new G4Element("Silicon"  , "Si", z=14., a= 28.085*g/mole);
G4Element* H = new G4Element("Hydrogen"  , "H", z=1., a= 1.008*g/mole);

G4Material* Shale = new G4Material("Shale", density= 2.6*g/cm3, nel=4);
Shale->AddElement(Al, 15*perCent);
Shale->AddElement(Si, 15*perCent);
Shale->AddElement(O, 38*perCent);
Shale->AddElement(H, 32*perCent);

Photon Attenuation in Shale

According to the XCOM database, the attenuation length for a 1.8 MeV photon is 0.16 /cm and 0.895 is 0.22/cm through shale.

File:XCOM attenuation4Shale.pdf


Directing a 1.8 MeV beam of photons in GEANT4 towards various thicknesses of shale produced the graph below.

GEANT4AttShale 3212012.png

XCOM predicts an attenuation coefficient of 0.0441 cm^2/g which becomes 0.12/cm when you multiply by the shale density of 2.6 g/cm^3. The fit to GEANT4's predictions above produces a value of 0.1/cm when you plot the number of photons that pass through the shale and still have an energy of 1.8 MeV.

If I use a point source isotropically emitting 1800 keV photons I observe

GEANT4AttShalePntSrc 322013.png

which gives a the value of 0.1/cm as well.

Yittrium in Shale

A simulation of the penetration of the 0.895 and 1.8 MeV photons from Yittrium through shale.

GEANT4 create a point source or 895 keV photon and another with 1800 keV photons iostropically distributed.

A 4" thick piece of shale was placed between the source and the detector.


Two ratios were constructed.

[math]R_p = \frac{\mbox{counts under the 1800 keV peak}}{\mbox{counts under the 895 keV peak}}[/math]

[math]R_I = \frac{\mbox{number of photons from 1800 keV source penetrating shale}}{\mbox{number of photons from 895 keV source penetrating shale}}[/math]

Y88ShaleNoCrack 1.png

Insert a single crack

A simulation was performed that predicted the transmission of photons through 10 centimeters of shale. The shale is in the form of a cylinder with a hole through the central axis.

The source was a uniform points source. One set of simulations used a 1.8 MeV photon and another used a 0.895 photon.


TF Crack Yit 04092013.png

Energy distribution

TF Crack Edist 895.pngTF Crack Edist 1800.png

Position Distribution

The Shale is a cylinder and the detector is a rectangle. A cut is used to look only at photons within the cylinder.


Units are Centimeters.

TF Crack PositnDist.pngTF Crack PositnDistCuts.png

Rates

A uniform point source sent 10^7 photons of a specific energy in all directions.

1 Curie = [math]3.7 \times 10^{10}[/math] decays/sec

Surface rates -vs- Crack size

The crack size decreases as you move from left to right in the table.

The result below is from a 1800 keV uniform point source and a 10 cm thick shale wall with a cylindrical hole through the center (X=0:Y=0)

TF 100mmCrack XvsY.png TF 25mmCrack XvsY.png TF 10mmCrack XvsY.png TF 5mmCrack XvsY.png TF 1mmCrack XvsY.png
100 mm hole 25 mm hole 10 mm 5 mm 1 mm


The result below is from a 895 keV uniform point source and a 10 cm thick shale wall with a cylindrical hole through the center (X=0:Y=0)

TF895 100mmCrack XvsY.png TF895 25mmCrack XvsY.png TF895 10mmCrack XvsY.png TF895 5mmCrack XvsY.png TF895 1mmCrack XvsY.png
100 mm hole 25 mm hole 10 mm 5 mm 1 mm

Now change the detector size from a 5 x 5 cm area to a 0.5 x 0.5 cm area.

TF 100mmCrack XvsY5x5.png TF 25mmCrack XvsY5x5.png TF 10mmCrack XvsY5x5.png TF 5mmCrack XvsY5x5.png TF 1mmCrack XvsY5x5.png
100 mm hole 25 mm hole 10 mm 5 mm 1 mm


The result below is from a 895 keV uniform point source and a 10 cm thick shale wall with a cylindrical hole through the center (X=0:Y=0)

TF895 100mmCrack XvsY5x5.png TF895 25mmCrack XvsY5x5.png TF895 10mmCrack XvsY5x5.png TF895 5mmCrack XvsY5x5.png TF895 1mmCrack XvsY5x5.png
100 mm hole 25 mm hole 10 mm 5 mm 1 mm

Peak

A projection is made along the X-axis with the cuts

  1. radius < 100 cm
  2. Energy > Source energy (0.89 or 1.7 MeV)

200 px200 px


TF_IsotopeTracers#Tracers_for_Cracks