2012AnnihCountrRateEstimate
Rate Estimates
Previous experiment at the IAC
|  |  |   | 
| IAC apparatus for positron production experiment | Counts observed when the dipole is tuned to direct positrons onto the Ta target | Counts from electrons on Ta target | 
- HpGe observed about 1 annihilation photon per 10 microCoulombs of electrons on the upstream Tungsten target
- Ratio of annihilation photons observed when using positrons to electrons 120 to 10
| Condition | Grade Calculation | 
| Electron Beam Energy | 10 MeV | 
| Peak current | 40 mA | 
| Pulse width | 100 ns | 
| Rep Rate | 300 Hz | 
NaI rate Ratio of positron to electron beam
Assumed Geometry
Assume a 2 mm thick Tungsten target that is 1" square
The target is located at -80 < Z < -80.2
The NaI crystal is 2.32" or 56.49 mm in diameter
The NaI crystal is 8" from the target then the opening angle is atan(2.32/8/2) = 8.25 degrees
Solid Angle
Chromox target
Chromox target is 0.011" thick = 0.279 mm
File:Chromox datasheet CERN.pdf
Rates using GEANT4
2 mm Thick Tungsten annihilation target
Integrating between 0.3 and 0.7 MeV (511 peak unclear)
Integrating between 0.3 and 0.7 MeV (511 peak unclear)
- Experiment at IAC had
Chromox
The photon rates produced when electrons and positrons interact with the ChroMox target and enter one of the NaI detectors haing a solid angle of (0.27 strad)
The photon rates predicted by GEANT4  when electrons and positrons interact with the ChroMox target and enter one of the NaI detectors haing a solid angle of (0.27 strad)