Design
New deisign: We changed to use just one magnet.
File:Emittance Test Optim File.txt
HRRL had steer magnets on itself. We don't need external steer magnets. But Dr. Chouffani said that we might need them after quads, if the quads are not on axis. He will think about it.
Beam Line design on 27th, Jul. 2010:
Optim File on 27th, Jul. 2010:
File:Emittance Test Optim File 27th Jul 2010.txt
File:HRRL Emittance.pdf
Faraday Cup
Old Beam Line
Beam Line Parts
Constructed Beam Line for Emittance Test
Vacuum pressure on the beam line is less than [math] 10^{-8} [/math] torr (on 2010-July-7th).
Leveling Survey
Downstream of the beam up by 2.6 mm.
How to do Leveling Survey and Alignment with Theodolite on e- Beam Line
A. Leveling Beam Pipe
1. Put the theodolite as high as the center of the beam line at upstream. Turn theodolite up and down. If the up angle is equal to down angle from the center of the pipe, theodolite is exactly as high as beam pipe. If not, adjust theodolite, until up and down angles are equal.
2. Once first step finished, then rotate theodolite horizontally to down stream. Turn it up and down, if up and down angles are not equal, adjust the stand till they are equal.
B. How to Make Sure the Quad is Perpendicular to the Beam Line
If the distances between quads and end of cavity at any given points are equal, then quad and end of cavity are parallel. Pipe is perpendicular to the end of the cavity, thus, magnet would also be perpendicular to the pipe.
I will find at lest three random points quads and three corresponding points at the end of the cavity, make sure they are equal, then I can say, magnet is perpendicular to the beam line.
I am planning to stick a metal ruler two, so two faces are parallel.
C. Centering the Quad Magnet with Theodolite
Vertical Centering
1. Finish the step 1 in A.
2. Then turn up the theodolite from the upper edge of the pipe to the magnet hole, call this angle upper angle. Do the same at lower part, call it lower angle. If the this two angles are not equal adjust the stand till they are equal.
Horizantal Centering
We know the diameter of the pipe [math] d_p [/math]. So, we can calculate from the pipe to the edge of the quad as:
We need to make sure this distance is same when measure it horizontally, so that our quad is centered on the pipe. I am going to use a ruler to ...(thinking)
July 2010 Run
- Initial Accelerator Settings
E = 10 MeV [math]\Rightarrow[/math] Control Voltage= 4.09 V
Pulse Width <= 50 ns
Average Beam Current = least amount needed to light up YaG crystal, start at 1 mA and Rep rate of 100 Hz.
At the same time we want to do radiation test on HRRL. This is for predicting the radiation after shifting cavity to new position.
Radiation test run plan is at: [1]
7/26/10
Alignment check
1.) Survey the Quad to be sure it is centered on the beam pipe
2.) survey the flag to determine if target is centered on the beam pipe
Transmission tuning
1.) Using the quads and accelerator coils, focus the beam on the YaG crystal to as fine a spot as possible. Monitor the FC during the focusing.
changed control Voltage from
Control Voltage= 4.9 V [math]\Rightarrow[/math] E = 16 MeV
to
4.09 V [math]\Rightarrow[/math] E = 10 MeV
Tune the 4 accelerator coils for max transmission.
We want to maximize the current reach the Farady Cup. This can be determined by the ratio on Channels of FC and Gun Current.
Gun current is the current on the pick up coil, which is input current for cavity. Current on Farady cup is the current reach the end of the beam line (FC is at the end of the beam line). We want to maximize the the ratio of Farady cup current to Gun current (FCC/GC), so there are more electrons will make it to the target. Thus, we enlarge our positron yield.
Basic principle: Fix three coils, change one till it maximized.
Coil 1 upstream left/right (mA) |
Coil 2 upstream UP/down (mA) |
Coil 3 downstream up/down |
Coil 4 downstream left right |
Scope Picture |
Gun Current |
FC current |
Transmission [math]\equiv[/math] Gun / FC
|
|
10 |
|
|
|
15 +/- 0.65 nV s |
-5.4[math]\pm[/math]1.8 nV s |
36 [math]\pm[/math] 12 %
|
The HRRL went down after 2 hours of operation.
7/27/10
No HRRL beam time today. Chad tested the Thermatron module and believes it is not the problem. Chad will continue debugging tomorrow.
Filament
BMP format:
Wiki won't allow me to upload with bmp extension. So, I used png extension to upload. After download files, you will find they are still with bmp extension.
7/28/10
The HRRL came back around 3pm today. A capacitor in the bank was found to be the problem.
Maximize Transmission
Maximized setup according to the accelerator operator.
Beam Energy: 16 MeV
Rep Rate: 95 Hz
Pulse Width: 100 ns
Coil 1 upstream left/right (A) |
Coil 2 upstream UP/down (A) |
Coil 3 downstream up/down (A) |
Coil 4 downstream left right (A) |
Scope Picture |
Gun Current |
FC current |
Ratio |
Spot Size
|
0.1 |
0.5 |
3.1 |
0.7 |
|
|
|
|
|
|
Reversed the polarities on coil # 3 and coil # 4. Rep rate: 3Hz
Coil 1 upstream left/right (A) |
Coil 2 upstream UP/down (A) |
Coil 3 downstream up/down (A) |
Coil 4 downstream left right (A) |
Scope Picture |
Gun Current |
FC current |
Ratio |
Spot Size
|
1.2 |
1.2 |
0.0 |
3 |
|
|
|
|
|
|
After image manipulation in GIMP to remove spot from the filament, Arne obtained reasonable projections for horizontal and vertical beam sizes ( < 2 mm). The quad was off, low rep rate to avoid saturation, 10MeV. This was the spot for the initial setup on Wednesday.
Electron beam deflection due to Earth's B-field.
It appears the the image from electrons hitting the YaG crystal is offset (to the right) compare to the image from the filament which appears near the center of the cross hairs.
Is the earths Magnetic field causing the electrons to move this far beam right?
[math]B_{Earth}[/math] = 0.00005 Tesla ( [math]\frac{ \mbox{kg}}{\mbox{C}\cdot \mbox{s}}[/math]) = 0.5 Gauss
E_{electron} = 10 MeV = Pc [math]\Rightarrow[/math] P = 10 MeV/c
Estimation using Classical Lorentz Force (forget about angle of B and V)
[math]\vec{F} = q \vec{v} \times \vec{B}[/math]
assuming [math]v[/math] and [math]B[/math] are orthogonal then we get the cyclotron radius
[math]F= qvB = m\frac{v^2}{r} \Rightarrow r = \frac{qB}{mv}[/math]
[math]r = \frac{(1.6 \times 10^{-19} \mbox{C}) \times ( 5 \times 10^{-5}\frac{\mbox{kg}}{\mbox{C} \cdot \mbox{s}})}{mv}[/math]
[math]mv = P = 10 \frac{ \mbox{MeV}}{\mbox{c}} = 5.6 \times 10^{-21} \frac{\mbox{kg} \cdot \mbox{m} }{\mbox{s}} [/math]
[math]\Rightarrow r = 700 \mbox{m}[/math]
Now some Geometry.
Assuming the orbit is a circle with a 700 m radius, then the question becomes how far does the electron move to maintain the orbit if it travels 1 m in a straight line.
let
[math]r[/math]= radius of circle
[math]l[/math]= distance along the beam line
[math]d[/math] = deflection due to gravity
- Note
- [math]l[/math] is a tangent to the orbit
one can construct a right angle triangle with side of length d, the [math]l[/math] as the base and [math]r+d[/math] as the hypotenuse.
Then Pythagorean's theorem gives
[math]r^2 + l^2 = (r+d)^2[/math]
Giving
[math]d^2+ (2r)d +l^2 =0[/math]
using quadratic formula you get
[math]2d = -(2r)/2 \pm \sqrt{(2r)^2 + 4\frac{l^2}{r^2}}/2[/math]
since l/r is very small (1/700) we can approximate this as
[math]d = -r \pm r \sqrt{1+ \frac{l^2}{r^2}} \approx \frac{l^2}{r} = \frac{l^2}\frac{P}{qB}= \frac{qBl^2}{P}[/math]
for 10 MeV and a 1 m long beam pipe
[math]d = (l\mbox {m})^2 \frac{(1.6 \times 10^{-19} \mbox{C}) \times ( 5 \times 10^{-5}\frac{\mbox{kg}}{\mbox{C} \cdot \mbox{s}})}{ 5.6 \times 10^{-21} \frac{\mbox{kg} \cdot \mbox{m} }{\mbox{s}} } = l^2 \times 1.42 \mbox{mm}[/math] where [math]l[/math] is in units of m
Spent the remaining beam time doing radiation footprint measurements.
HRRL_radiation_tests#Run_Plan
7/29/10
Today we first tune up the beam for max transmission.
If the above calculation is correct we can expect the electron beam to move at least 2 mm away from the center of the FC. We could test it the Earth's B-field is the cause of the deflection by watch the deflection as a function of the beam energy. If we had enough [math]\mu[/math]-metal we could wrap the beam pipe in it and see if the deflection goes away.
Quad Scan
First Scan
- Beam current
- [math]\frac{535.4 \pm 23.4 \times 10^{-12} \;\mbox{V} \cdot \mbox{s} }{50 \Omega} = 10.71 \pm 0.478 \times 10^{-12}\mbox{ C}[/math]
- [math]\frac{10.71 \pm 0.478 \times 10^{-12}\mbox{ C}}{105 \times 10^{-9}\; \mbox{s}} = 102 \pm 4.46 \mu \mbox{A peak current}[/math]
Second Scan (Polarity Changed)
PS Output Current to Shunt Resistance Current Conversion
PS negative connected to Quad positive.
Shunt resistance: 50 AMP, 50 MV. (PR 0050, QECO)
PS Reading (Amps) |
Shunt Resistance Voltage (mV) |
Shunt Resistance Current (Amps) (Calculated)
|
0 |
0 |
0
|
1 |
1 |
1
|
2 |
2.1 |
2.1
|
3 |
3.2 |
3.2
|
4 |
4.3 |
4.3
|
5 |
5.4 |
5.4
|
6 |
6.4 |
6.4
|
7 |
7.4 |
7.4
|
8 |
8.5 |
8.5
|
9 |
9.6 |
9.6
|
10 |
10.7 |
10.7
|
11 |
11.7 |
11.7
|
12 |
12.8 |
12.8
|
13 |
13.9 |
13.9
|
14 |
14.9 |
14.9
|
15 |
16 |
16
|
16 |
17 |
17
|
17 |
18.1 |
18.1
|
18 |
19.2 |
19.2
|
19 |
20.3 |
20.3
|
20 |
21.3 |
21.3
|
21 |
22.4 |
22.4
|
22 |
23.5 |
23.5
|
spent noon to 3pm on radiation measurements below
HRRL_radiation_tests#29_Jul_2010
Earth's B-field effect
It the above calculation on the effects of the Earth's Magnetic field on a the electron beam is correct then we should see the amount of deflection depend inversely on the electron's momentum (1/P).
So lets take a few pictures at the energy exterma to see how far the electron spot moves away from the filament image on the crystal.
E beam (V gun) |
YaG picture |
Beam Spot posiiton (arb offset)
|
5 |
100 px |
|
|
10 (4.09 V) |
|
-31.8 [math]\pm[/math] .1 mm
|
16 (4.9 V) |
|
-32.0 [math]\pm[/math] 0.1 mm
|
We did not see the beam spot move when the energy was changed from 10 MeV to 16 MeV, but going to lower energy definitely moved the beam spot farther away from the center filament image that is located on the YaG crystal cross hairs.
Maximize Transmission
Change the linac coils to determine a setting which delivers the maximum current to the FC and has a reasonable spot size on the YaG viewer.
Coil 1 upstream left/right (A) |
Coil 2 upstream UP/down (A) |
Coil 3 downstream up/down |
Coil 4 downstream left right |
Scope Picture |
Gun Current |
FC current |
Ratio |
YaG Image
|
0 |
0.6 |
1.8 |
2.7 |
|
|
|
|
|
Coil 1 upstream left/right (A) |
Coil 2 upstream UP/down (A) |
Coil 3 downstream up/down |
Coil 4 downstream left right |
Scope Picture |
Gun Current |
FC current |
Ratio |
YaG Image
|
0 |
0.6 |
1.8 |
2.7 |
100px |
|
|
|
100px
|
a.) Does a small beam spot size on the crystal give maximum FC signal?
b.) Is there a point where the spot size changes and you can't resolve a change in the FC output?
c.) Remove the YaG target and determine if above observations are unchanged.
Pickup Coil Calibration
2.) After tuning the beam to deliver the Maximum beam current to the FC, measure the FC and green pickup coil output as a function of current by integrating the pulse with an oscilloscope.
FC output |
Green Pickup Coil output |
Spot on Crystal |
Scope
|
(mA) |
(mA) |
|
|
|
0.5 |
|
|
|
1 |
|
|
|
1.5 |
|
|
|
2 |
|
|
|
2.5 |
|
|
|
3 |
|
|
|
3.5 |
|
|
|
4 |
|
|
|
4.5 |
|
|
|
5 |
|
|
|
5.5 |
|
|
|
6 |
|
|
a.) does the FC output change with rep rate? It should not but maybe there is loss at high rates?
Quad scan
Tune the beam so a change in the quad B-field does not cause a deflection.
First attempt to measure the spot size change as a function of Quad current
Quad Current |
Beam Spot RMS (0 degrees= Left/right) |
Beam Spot RMS (90 degrees= Up/Down)
|
(Amps) |
(mm) |
(mm)
|
|
|
|
|
|
|
Shall we do both polarities?
Imaging
Background subtraction
The filament produces at least a 2 mm diameter spot on the YaG crystal. Beam dominates the image.
7/30/10
At 4pm yesterday we attempted to measure the emittance at high currents of 10 mA, previous measurements were at 0.3 mA. The beam spot became larger than the 1" YaG target holder. This would make emittance measurements impossible.
In order to measure the emittance above 1 mA we will need to insert a doublet as close to the accelerator entrance as possible. Since this would not be done by today we decided to cancel today's beam time and work on the next emittance measurement.
The YaG camera saturated at about 0.6 mA of beam current (our measurements were made at about 0.3 mA). Perhaps we should use a thin Aluminum target instead of the YaG crystal for high current measurements.
We were able to Trigger the GigE camera. We should use this next time.
Imaging scratch area
After image manipulation in GIMP to remove spot from filament. Obtained reasonable projections for horizontal and vertical beam sizes. The quad was off, low rep rate to avoid saturation, 10MeV. This was the spot for the initial setup on Wednesday.
Data Analysis
Root Code: File:Pixle.C
The cut is changed from circular to elliptical on Sep. 23rd, 2010.
Rotating the Image
Images need to be rotated -6 degree, so cross at center of the crystal is perpendicular to the image. Here are the rotated images
1st Scan
2nd Scan
Polarity was switched from 1st scan.
Fits for Beam Spot Projection
1st Scan
2nd Scan
Coil Current vs Beam Spot Projection Gaussian Fit's Sigma
1st Scan
Coil Current Reading on PS (Amps) |
Coil Current Reading From Shunt Resistance (Amps) |
X Projection Sigma (pixels) |
Y Projection Sigma (pixels)
|
0 |
0 |
30.28 |
30.69
|
1 |
1 |
31.6 |
29.81
|
1.4 |
|
32.3 |
29.37
|
2 |
2.1 |
32.93 |
2864
|
3 |
3.2 |
34.45 |
27.85
|
4 |
4.3 |
35.51 |
27.3
|
5 |
5.4 |
36.28 |
27.06
|
6 |
6.4 |
37.22 |
26.52
|
7 |
7.4 |
38.14 |
26.8
|
8 |
8.5 |
38.89 |
26.97
|
9 |
9.6 |
38.59 |
28.29
|
10 |
10.7 |
39.97 |
27.44
|
11 |
11.7 |
39.8 |
27.72
|
12 |
12.8 |
40.35 |
27.67
|
13 |
13.9 |
40.06 |
27.67
|
14 |
14.9 |
40.2 |
27.76
|
15 |
16 |
40.26 |
27.96
|
16 |
17 |
40.84 |
27.81
|
17 |
18.1 |
41.41 |
27.93
|
18 |
19.2 |
41.55 |
28.12
|
19 |
20.3 |
41.41 |
28.18
|
20 |
21.3 |
42.25 |
28.58
|
2nd Scan
Coil Current Reading on PS (Amps) |
Coil Current Reading From Shunt Resistance (Amps) |
X Projection Sigma (pixels) |
Y Projection Sigma (pixels)
|
0 |
0 |
31.68 |
33.79
|
1 |
1 |
30.51 |
34.77
|
2 |
2.1 |
29.72 |
36.33
|
3 |
3.2 |
28.81 |
37.6
|
4 |
4.3 |
28.11 |
38.3
|
5 |
5.4 |
27.99 |
38.45
|
6 |
6.4 |
27.78 |
39.73
|
7 |
7.4 |
28.07 |
39.32
|
8 |
8.5 |
27.91 |
39.31
|
9 |
9.6 |
28.38 |
41.08
|
10 |
10.7 |
28.62 |
41.87
|
11 |
11.7 |
28.66 |
41.52
|
12 |
12.8 |
28.91 |
42.31
|
13 |
13.9 |
28.8 |
42.16
|
14 |
14.9 |
28.95 |
42.41
|
15 |
16 |
29.06 |
42.58
|
16 |
17 |
29.27 |
42.95
|
17 |
18.1 |
29.15 |
43.26
|
18 |
19.2 |
29.01 |
42.98
|
19 |
20.3 |
29.05 |
42.61
|
20 |
21.3 |
28.93 |
43.63
|
22 |
23.5 |
29.08 |
44.39
|
Multi-Fits for Beam Spot Projection
Multi-Fits 1st Scan
Naming the photos: Rotated_HRRL_Emit_Test_Quad_Scan_First_20Amp_Multi_Fit7 -> RHETQSF20AMF7
Coild Current (Amps) |
1st Fit |
2nd Fit |
3rd Fit |
4th Fit |
5th Fit |
6th Fit |
7th Fit |
Mean and Error
|
0 |
[math]{\sigma}_{x,y}= 21.4,22.5 [/math] |
[math]{\sigma}_{x,y}= 25.5,23.2 [/math] |
[math]{\sigma}_{x,y}= 22.9,24.5 [/math] |
[math]{\sigma}_{x,y}= 28.2,25.0 [/math] |
[math]{\sigma}_{x,y}= 26.1,25.7 [/math] |
[math]{\sigma}_{x,y}= 26.6,28.2 [/math] |
[math]{\sigma}_{x,y}= 26.3,27.3 [/math] |
[math]{\sigma}_{x,y}= 25.3\pm2.2 , 25.2 \pm1.9 [/math]
|
1 |
[math]{\sigma}_{x,y}= 22.3,21.5 [/math] |
[math]{\sigma}_{x,y}= 25.1,21.8 [/math] |
[math]{\sigma}_{x,y}= 22.9,24.5 [/math] |
[math]{\sigma}_{x,y}= 25.5,22.6 [/math] |
[math]{\sigma}_{x,y}= 28.7,28.2 [/math] |
[math]{\sigma}_{x,y}= 33.3,26.3 [/math] |
[math]{\sigma}_{x,y}= 35.0,28.4 [/math] |
[math]{\sigma}_{x,y}= 27.5\pm4.6 , 24.8 \pm 2.7 [/math]
|
2 |
[math]{\sigma}_{x,y}= 21.2,20.2 [/math] |
[math]{\sigma}_{x,y}= 22.8,20.7 [/math] |
[math]{\sigma}_{x,y}= 27.9,21.2 [/math] |
[math]{\sigma}_{x,y}= 35.0,27.1 [/math] |
[math]{\sigma}_{x,y}= 36.6,26.6 [/math] |
[math]{\sigma}_{x,y}= 36.6,26.0 [/math] |
[math]{\sigma}_{x,y}= 40.0,24.6 [/math] |
[math]{\sigma}_{x,y}= 31.4 \pm 6.9 , 23.8 \pm 2.8 [/math]
|
3 |
[math]{\sigma}_{x,y}= 28.7,19.6 [/math] |
[math]{\sigma}_{x,y}= 30.4,20.1 [/math] |
[math]{\sigma}_{x,y}= 29.8,20.0 [/math] |
[math]{\sigma}_{x,y}= 38.8,13.3 [/math] |
[math]{\sigma}_{x,y}= 39.5,26.8 [/math] |
[math]{\sigma}_{x,y}= 38.8,27.4 [/math] |
[math]{\sigma}_{x,y}= 41.0,25.6 [/math] |
[math]{\sigma}_{x,y}= 35.3 \pm 5.0 , 21.8 \pm 4.7 [/math]
|
4 |
[math]{\sigma}_{x,y}= 28.2,17.6 [/math] |
[math]{\sigma}_{x,y}= 30.2,17.6 [/math] |
[math]{\sigma}_{x,y}= 29.9,18.1 [/math] |
[math]{\sigma}_{x,y}= 37.1,29.8 [/math] |
[math]{\sigma}_{x,y}= 39.4,18.5 [/math] |
[math]{\sigma}_{x,y}= 40.3,19.1 [/math] |
[math]{\sigma}_{x,y}= 42.9,19.2 [/math] |
[math]{\sigma}_{x,y}= 35.4 \pm 5.5 , 20.0 \pm 4.1 [/math]
|
5 |
[math]{\sigma}_{x,y}= 33.0,17.0 [/math] |
[math]{\sigma}_{x,y}= 33.5,16.6 [/math] |
[math]{\sigma}_{x,y}= 31.1,17.2 [/math] |
[math]{\sigma}_{x,y}= 37.0,17.9 [/math] |
[math]{\sigma}_{x,y}= 40.0,18.2 [/math] |
[math]{\sigma}_{x,y}= 41.8,18.5 [/math] |
[math]{\sigma}_{x,y}= 42.5,18.0 [/math] |
[math]{\sigma}_{x,y}= 37.0 \pm 4.2 , 17.6 \pm 0.6 [/math]
|
6 |
[math]{\sigma}_{x,y}= 31.8,15.4 [/math] |
[math]{\sigma}_{x,y}= 34.7,15.6 [/math] |
[math]{\sigma}_{x,y}= 33.4,16.3 [/math] |
[math]{\sigma}_{x,y}= 41.0,16.4 [/math] |
[math]{\sigma}_{x,y}= 41.4,16.2 [/math] |
[math]{\sigma}_{x,y}= 43.2,16.8 [/math] |
[math]{\sigma}_{x,y}= 44.8,16.2 [/math] |
[math]{\sigma}_{x,y}= 38.6 \pm 4.8 , 16.1 \pm 0.4 [/math]
|
7 |
[math]{\sigma}_{x,y}= 36.4,14.8 [/math] |
[math]{\sigma}_{x,y}= 39.3,15.3 [/math] |
[math]{\sigma}_{x,y}= 40.7,14.9 [/math] |
[math]{\sigma}_{x,y}= 43.6,15.1 [/math] |
[math]{\sigma}_{x,y}= 43.0,15.5 [/math] |
[math]{\sigma}_{x,y}= 44.2,15.9 [/math] |
[math]{\sigma}_{x,y}= 49.3,16.1 [/math] |
[math]{\sigma}_{x,y}= 42.4 \pm 3.8 , 15.4 \pm 0.5 [/math]
|
8 |
[math]{\sigma}_{x,y}= 37.9,14.7 [/math] |
[math]{\sigma}_{x,y}= 43.0,14.7 [/math] |
[math]{\sigma}_{x,y}= 40.0,14.0 [/math] |
[math]{\sigma}_{x,y}= 44.0,15.7 [/math] |
[math]{\sigma}_{x,y}= 44.0,15.5 [/math] |
[math]{\sigma}_{x,y}= 43.9,15.3 [/math] |
[math]{\sigma}_{x,y}= 44.1,15.0 [/math] |
[math]{\sigma}_{x,y}= 42.4 \pm 2.3 , 15.0 \pm 0.5 [/math]
|
9 |
[math]{\sigma}_{x,y}= 41.0,12.5 [/math] |
[math]{\sigma}_{x,y}= 39.0,13.0 [/math] |
[math]{\sigma}_{x,y}= 41.0,12.9 [/math] |
[math]{\sigma}_{x,y}= 43.0,14.4 [/math] |
[math]{\sigma}_{x,y}= 45.0,14.7 [/math] |
[math]{\sigma}_{x,y}= 44.9,15.0 [/math] |
[math]{\sigma}_{x,y}= 46.0,16.0 [/math] |
[math]{\sigma}_{x,y}= 42.8 \pm 2.4 , 14.1 \pm 1.2 [/math]
|
10 |
[math]{\sigma}_{x,y}= 41.0,14.0 [/math] |
[math]{\sigma}_{x,y}= 45.7,13.7 [/math] |
[math]{\sigma}_{x,y}= 41.5,14.2 [/math] |
[math]{\sigma}_{x,y}= 46.2,13.6 [/math] |
[math]{\sigma}_{x,y}= 46.0,14.7 [/math] |
[math]{\sigma}_{x,y}= 45.0,14.2 [/math] |
[math]{\sigma}_{x,y}= 46.9,14.1 [/math] |
[math]{\sigma}_{x,y}= 44.6 \pm 2.2 , 14.4 \pm 0.3 [/math]
|
11 |
[math]{\sigma}_{x,y}= 45.4,13.2 [/math] |
[math]{\sigma}_{x,y}= 47.2,12.0 [/math] |
[math]{\sigma}_{x,y}= 46.4,12.3 [/math] |
[math]{\sigma}_{x,y}= 46.4,13.2 [/math] |
[math]{\sigma}_{x,y}= 46.7,14.5 [/math] |
[math]{\sigma}_{x,y}= 47.0,14.3 [/math] |
[math]{\sigma}_{x,y}= 47.2,14.6 [/math] |
[math]{\sigma}_{x,y}= 46.6 \pm 0.6 , 13.5 \pm 1.0 [/math]
|
12 |
[math]{\sigma}_{x,y}= 44.5,11.6 [/math] |
[math]{\sigma}_{x,y}= 44.9,12.0 [/math] |
[math]{\sigma}_{x,y}= 46.4,11.9 [/math] |
[math]{\sigma}_{x,y}= 48.6,11.8 [/math] |
[math]{\sigma}_{x,y}= 49.1,11.6 [/math] |
[math]{\sigma}_{x,y}= 47.8,13.0 [/math] |
[math]{\sigma}_{x,y}= 50.0,12.7 [/math] |
[math]{\sigma}_{x,y}= 47.3 \pm 2.0 , 12.1 \pm 0.5 [/math]
|
13 |
[math]{\sigma}_{x,y}= 48.0,11.8 [/math] |
[math]{\sigma}_{x,y}= 50.0,11.6 [/math] |
[math]{\sigma}_{x,y}= 50.2,12.1 [/math] |
[math]{\sigma}_{x,y}= 49.2,11.0 [/math] |
[math]{\sigma}_{x,y}= 50.6,11.2 [/math] |
[math]{\sigma}_{x,y}= 50.0,12.0 [/math] |
[math]{\sigma}_{x,y}= 51.6,11.6 [/math] |
[math]{\sigma}_{x,y}= 49.9 \pm 1.0 , 11.6 \pm 0.4 [/math]
|
14 |
[math]{\sigma}_{x,y}= 51.0,11.8 [/math] |
[math]{\sigma}_{x,y}= 51.0,11.2 [/math] |
[math]{\sigma}_{x,y}= 51.3,11.2 [/math] |
[math]{\sigma}_{x,y}= 50.7,11.6 [/math] |
[math]{\sigma}_{x,y}= 52.2,11.7 [/math] |
[math]{\sigma}_{x,y}= 51.8,11.6 [/math] |
[math]{\sigma}_{x,y}= 52.7,11.4 [/math] |
[math]{\sigma}_{x,y}= 51.5 \pm 0.7 , 11.5 \pm 0.2 [/math]
|
15 |
[math]{\sigma}_{x,y}= 52.3,12.0 [/math] |
[math]{\sigma}_{x,y}= 50.0,11.6 [/math] |
[math]{\sigma}_{x,y}= 51.0,11.3 [/math] |
[math]{\sigma}_{x,y}= 50.6,11.6 [/math] |
[math]{\sigma}_{x,y}= 53.0,11.5 [/math] |
[math]{\sigma}_{x,y}= 53.2,11.9 [/math] |
[math]{\sigma}_{x,y}= 52.7,12.0 [/math] |
[math]{\sigma}_{x,y}= 51.8 \pm 1.2 , 11.7 \pm 0.3 [/math]
|
16 |
[math]{\sigma}_{x,y}= 53.4,12.5 [/math] |
[math]{\sigma}_{x,y}= 54.0,12.0 [/math] |
[math]{\sigma}_{x,y}= 54.3,11.8 [/math] |
[math]{\sigma}_{x,y}= 51.5,11.5 [/math] |
[math]{\sigma}_{x,y}= 53.3,12.7 [/math] |
[math]{\sigma}_{x,y}= 52.1,12.8 [/math] |
[math]{\sigma}_{x,y}= 55.0,12.5 [/math] |
[math]{\sigma}_{x,y}= 53.4 \pm 1.1 , 12.3 \pm 0.5 [/math]
|
17 |
[math]{\sigma}_{x,y}= 55.0,13.4 [/math] |
[math]{\sigma}_{x,y}= 56.5,13.8 [/math] |
[math]{\sigma}_{x,y}= 56.8,13.9 [/math] |
[math]{\sigma}_{x,y}= 55.9,12.9 [/math] |
[math]{\sigma}_{x,y}= 56.0,11.9 [/math] |
[math]{\sigma}_{x,y}= 57.4,12.2 [/math] |
[math]{\sigma}_{x,y}= 58.0,13.3 [/math] |
[math]{\sigma}_{x,y}= 56.5 \pm 0.9 , 13.1 \pm 0.7 [/math]
|
18 |
[math]{\sigma}_{x,y}= 59.0,14.0 [/math] |
[math]{\sigma}_{x,y}= 56.0,13.2 [/math] |
[math]{\sigma}_{x,y}= 56.0,13.4 [/math] |
[math]{\sigma}_{x,y}= 55.0,13.9 [/math] |
[math]{\sigma}_{x,y}= 56.1,14.1 [/math] |
[math]{\sigma}_{x,y}= 53.5,13.4 [/math] |
[math]{\sigma}_{x,y}= 59.0,13.0 [/math] |
[math]{\sigma}_{x,y}= 56.4 \pm 1.9 , 13.6 \pm 0.4 [/math]
|
19 |
[math]{\sigma}_{x,y}= 60.7,16.1 [/math] |
[math]{\sigma}_{x,y}= 53.0,15.0 [/math] |
[math]{\sigma}_{x,y}= 60.0,15.7 [/math] |
[math]{\sigma}_{x,y}= 55.7,14.1 [/math] |
[math]{\sigma}_{x,y}= 58.8,15.0 [/math] |
[math]{\sigma}_{x,y}= 53.0,14.0 [/math] |
[math]{\sigma}_{x,y}= 54.5,15.0 [/math] |
[math]{\sigma}_{x,y}= 56.5 \pm 3.0 , 15.0 \pm 0.7 [/math]
|
20 |
[math]{\sigma}_{x,y}= 62.0,18.9 [/math] |
[math]{\sigma}_{x,y}= 60.0,19.0 [/math] |
[math]{\sigma}_{x,y}= 59.0,19.3 [/math] |
[math]{\sigma}_{x,y}= 56.0,17.0 [/math] |
[math]{\sigma}_{x,y}= 55.6,17.2 [/math] |
[math]{\sigma}_{x,y}= 56.0,17.0 [/math] |
[math]{\sigma}_{x,y}= 55.7,17.3 [/math] |
[math]{\sigma}_{x,y}= 57.8 \pm 2.4 , 18.0 \pm 1.0 [/math]
|
Multi-Fits 2nd Scan
Naming the photos: Rotated_HRRL_Emit_Test_Quad_Scan_Second_22Amp_Multi_Fit7 -> RHETQSS22AMF7
Coild Current (Amps) |
1st Fit |
2nd Fit |
3rd Fit |
4th Fit |
5th Fit |
6th Fit |
7th Fit |
Mean and Error
|
0 |
[math]{\sigma}_{x,y}=27.8,29.2 [/math] |
[math]{\sigma}_{x,y}=28.4,30.5 [/math] |
[math]{\sigma}_{x,y}=28.5,32.1 [/math] |
[math]{\sigma}_{x,y}=29.8,37.4 [/math] |
[math]{\sigma}_{x,y}=33.7,38.5 [/math] |
[math]{\sigma}_{x,y}=33.4,38.6 [/math] |
[math]{\sigma}_{x,y}=36.3,38.0 [/math] |
[math]{\sigma}_{x,y}=31.1 \pm 3.1,34.9\pm3.8 [/math]
|
1 |
[math]{\sigma}_{x,y}=22.6,28.5 [/math] |
[math]{\sigma}_{x,y}=24.5,30.7 [/math] |
[math]{\sigma}_{x,y}=23.1,29.9 [/math] |
[math]{\sigma}_{x,y}=27.4,41.0 [/math] |
[math]{\sigma}_{x,y}=27.1,38.6 [/math] |
[math]{\sigma}_{x,y}=26.5,39.8 [/math] |
[math]{\sigma}_{x,y}=27.0,39.7 [/math] |
[math]{\sigma}_{x,y}= 25.5 \pm 1.9 , 35.5 \pm 5.1 [/math]
|
2 |
[math]{\sigma}_{x,y}=23.5,32.9 [/math] |
[math]{\sigma}_{x,y}=24.2,33.5 [/math] |
[math]{\sigma}_{x,y}=22.7,34.7 [/math] |
[math]{\sigma}_{x,y}=26.3,41.0 [/math] |
[math]{\sigma}_{x,y}=26.8,45.8 [/math] |
[math]{\sigma}_{x,y}=26.1,44.1 [/math] |
[math]{\sigma}_{x,y}=26.5,48.9 [/math] |
[math]{\sigma}_{x,y}= 25.2 \pm 1.5 , 40.1 \pm 6.0 [/math]
|
3 |
[math]{\sigma}_{x,y}=22.6,37.0 [/math] |
[math]{\sigma}_{x,y}=22.9,36.4 [/math] |
[math]{\sigma}_{x,y}=21.7,37.6 [/math] |
[math]{\sigma}_{x,y}=23.8,39.5 [/math] |
[math]{\sigma}_{x,y}=23.8,42.3 [/math] |
[math]{\sigma}_{x,y}=24.1,42.3 [/math] |
[math]{\sigma}_{x,y}=25.4,42.3 [/math] |
[math]{\sigma}_{x,y}=23.5 \pm 1.1 , 39.6\pm 2.5 [/math]
|
4 |
[math]{\sigma}_{x,y}=19.9,38.8 [/math] |
[math]{\sigma}_{x,y}=19.8,38.1 [/math] |
[math]{\sigma}_{x,y}=19.1,39.3 [/math] |
[math]{\sigma}_{x,y}=20.5,41.3 [/math] |
[math]{\sigma}_{x,y}=20.8,42.2 [/math] |
[math]{\sigma}_{x,y}=21.1,43.3 [/math] |
[math]{\sigma}_{x,y}=21.4,44.4 [/math] |
[math]{\sigma}_{x,y}= 20.4\pm 0.8 , 41.1\pm 2.2 [/math]
|
5 |
[math]{\sigma}_{x,y}=18.2,43.3 [/math] |
[math]{\sigma}_{x,y}=18.0,45.9 [/math] |
[math]{\sigma}_{x,y}=17.9,48.1 [/math] |
[math]{\sigma}_{x,y}=18.2,47.9 [/math] |
[math]{\sigma}_{x,y}=18.2,40.9 [/math] |
[math]{\sigma}_{x,y}=17.0,48.5 [/math] |
[math]{\sigma}_{x,y}=18.4,48.0 [/math] |
[math]{\sigma}_{x,y}= 18.0 \pm 0.4 , 46.1 \pm 2.7 [/math]
|
6 |
[math]{\sigma}_{x,y}=16.4,47.0 [/math] |
[math]{\sigma}_{x,y}=16.2,48.4 [/math] |
[math]{\sigma}_{x,y}=15.7,50.6 [/math] |
[math]{\sigma}_{x,y}=16.6,50.5 [/math] |
[math]{\sigma}_{x,y}=16.5,46.9 [/math] |
[math]{\sigma}_{x,y}=16.0,50.6 [/math] |
[math]{\sigma}_{x,y}=16.3,50.6 [/math] |
[math]{\sigma}_{x,y}= 16.2 \pm 0.3 , 49.2\pm 1.6 [/math]
|
7 |
[math]{\sigma}_{x,y}=13.1,44.5 [/math] |
[math]{\sigma}_{x,y}=12.8,46.8 [/math] |
[math]{\sigma}_{x,y}=13.2,49.3 [/math] |
[math]{\sigma}_{x,y}=13.3,49.6 [/math] |
[math]{\sigma}_{x,y}=13.7,45.2 [/math] |
[math]{\sigma}_{x,y}=13.9,49.7 [/math] |
[math]{\sigma}_{x,y}=12.8,49.6 [/math] |
[math]{\sigma}_{x,y}= 13.3\pm0.4 , 47.8\pm 2.1 [/math]
|
8 |
[math]{\sigma}_{x,y}=12.3,49.0 [/math] |
[math]{\sigma}_{x,y}=12.4,46.7 [/math] |
[math]{\sigma}_{x,y}=11.7,49.3 [/math] |
[math]{\sigma}_{x,y}=11.6,49.2 [/math] |
[math]{\sigma}_{x,y}=13.1,45.0 [/math] |
[math]{\sigma}_{x,y}=13.0,50.0 [/math] |
[math]{\sigma}_{x,y}=12.3,49.6 [/math] |
[math]{\sigma}_{x,y}= 12.3\pm 0.5 , 48.4 \pm 1.7 [/math]
|
9 |
[math]{\sigma}_{x,y}=13.3,50.4 [/math] |
[math]{\sigma}_{x,y}=13.2,52.4 [/math] |
[math]{\sigma}_{x,y}=13.1,55.7 [/math] |
[math]{\sigma}_{x,y}=13.5,54.8 [/math] |
[math]{\sigma}_{x,y}=13.3,50.0 [/math] |
[math]{\sigma}_{x,y}=13.5,53.4 [/math] |
[math]{\sigma}_{x,y}=13.2,54.5 [/math] |
[math]{\sigma}_{x,y}= 13.3 \pm 0.1 ,53.0 \pm 2.0 [/math]
|
10 |
[math]{\sigma}_{x,y}=12.6,53.8 [/math] |
[math]{\sigma}_{x,y}=13.0,54.9 [/math] |
[math]{\sigma}_{x,y}=12.4,58.5 [/math] |
[math]{\sigma}_{x,y}=12.9,57.7 [/math] |
[math]{\sigma}_{x,y}=12.7,52.7 [/math] |
[math]{\sigma}_{x,y}=12.8,55.0 [/math] |
[math]{\sigma}_{x,y}=12.0,56.6 [/math] |
[math]{\sigma}_{x,y}= 12.6 \pm 0.3 , 55.6 \pm 1.9 [/math]
|
11 |
[math]{\sigma}_{x,y}=10.1,52.2 [/math] |
[math]{\sigma}_{x,y}=10.2,52.4 [/math] |
[math]{\sigma}_{x,y}=9.8,58.3 [/math] |
[math]{\sigma}_{x,y}=9.7,56.9 [/math] |
[math]{\sigma}_{x,y}=10.9,51.3 [/math] |
[math]{\sigma}_{x,y}=10.0,54.5 [/math] |
[math]{\sigma}_{x,y}=9.7,55.4 [/math] |
[math]{\sigma}_{x,y}= 10.1 \pm 0.4 ,54.4 \pm 2.4 [/math]
|
12 |
[math]{\sigma}_{x,y}=11.2,55.9 [/math] |
[math]{\sigma}_{x,y}=10.8,55.0 [/math] |
[math]{\sigma}_{x,y}=11.0,60.1 [/math] |
[math]{\sigma}_{x,y}=10.5,59.8 [/math] |
[math]{\sigma}_{x,y}=11.1,56.2 [/math] |
[math]{\sigma}_{x,y}=10.4,56.4 [/math] |
[math]{\sigma}_{x,y}=10.4,58.0 [/math] |
[math]{\sigma}_{x,y}= 10.8\pm 0.9, 57.3\pm1.8 [/math]
|
13 |
[math]{\sigma}_{x,y}=8.9,54.8 [/math] |
[math]{\sigma}_{x,y}=9.1,56.2 [/math] |
[math]{\sigma}_{x,y}=8.7,60.4 [/math] |
[math]{\sigma}_{x,y}=8.7,59.6 [/math] |
[math]{\sigma}_{x,y}=9.1,53.5 [/math] |
[math]{\sigma}_{x,y}=8.8,56.3 [/math] |
[math]{\sigma}_{x,y}=8.7,57.1 [/math] |
[math]{\sigma}_{x,y}= 8.9 \pm 0.2 , 56.8 \pm 2.3 [/math]
|
14 |
[math]{\sigma}_{x,y}=10.5,57.4 [/math] |
[math]{\sigma}_{x,y}=10.9,56.0 [/math] |
File:RHETQSS14AMF3.png [math]{\sigma}_{x,y}=10.7,61.0 [/math] |
[math]{\sigma}_{x,y}=10.7,60.7 [/math] |
[math]{\sigma}_{x,y}=10.6,54.9 [/math] |
[math]{\sigma}_{x,y}=10.9,60.6 [/math] |
[math]{\sigma}_{x,y}=10.3,58.7 [/math] |
[math]{\sigma}_{x,y}= 10.7 \pm 0.2 , 58.5\pm 2.3 [/math]
|
15 |
[math]{\sigma}_{x,y}=10.0,57.4 [/math] |
[math]{\sigma}_{x,y}=10.8,55.2 [/math] |
[math]{\sigma}_{x,y}=10.7,60.3 [/math] |
[math]{\sigma}_{x,y}=10.5,58.7 [/math] |
[math]{\sigma}_{x,y}=10.7,55.0 [/math] |
[math]{\sigma}_{x,y}=10.3,57.4 [/math] |
[math]{\sigma}_{x,y}=10.2,58.7 [/math] |
[math]{\sigma}_{x,y}= 10.5 \pm 0.3 , 57.5 \pm 1.8 [/math]
|
16 |
[math]{\sigma}_{x,y}=10.5,60.6 [/math] |
[math]{\sigma}_{x,y}=11.2,55.8 [/math] |
[math]{\sigma}_{x,y}=11.5,63.4 [/math] |
[math]{\sigma}_{x,y}=11.1,62.3 [/math] |
[math]{\sigma}_{x,y}=12.0,56.8 [/math] |
[math]{\sigma}_{x,y}=11.4,60.6 [/math] |
[math]{\sigma}_{x,y}=11.3,56.0 [/math] |
[math]{\sigma}_{x,y}= 11.3 \pm 0.4 , 59.4 \pm 2.9 [/math]
|
17 |
[math]{\sigma}_{x,y}= 12.2,57.6[/math] |
[math]{\sigma}_{x,y}=13.6,58.7 [/math] |
[math]{\sigma}_{x,y}=12.1,63.4 [/math] |
[math]{\sigma}_{x,y}=11.2,57.4 [/math] |
[math]{\sigma}_{x,y}=12.0,57.6 [/math] |
[math]{\sigma}_{x,y}=12.0,58.7 [/math] |
[math]{\sigma}_{x,y}=12.4,64.0 [/math] |
[math]{\sigma}_{x,y}= 12.2 \pm 0.7 , 59.6 \pm 2.6 [/math]
|
18 |
[math]{\sigma}_{x,y}=11.4,59.7 [/math] |
[math]{\sigma}_{x,y}=12.0,55.7 [/math] |
[math]{\sigma}_{x,y}=13.2,61.4 [/math] |
[math]{\sigma}_{x,y}=13.3,59.0 [/math] |
[math]{\sigma}_{x,y}=12.5,58.5 [/math] |
[math]{\sigma}_{x,y}=12.3,60.2 [/math] |
[math]{\sigma}_{x,y}=11.9,58.3 [/math] |
[math]{\sigma}_{x,y}= 12.4 \pm 0.6 , 59.0\pm 1.7 [/math]
|
19 |
[math]{\sigma}_{x,y}=19.99,59.0 [/math] |
[math]{\sigma}_{x,y}=13.5,52.6 [/math] |
[math]{\sigma}_{x,y}= 11.5,62.0[/math] |
[math]{\sigma}_{x,y}=12.2 [/math] |
[math]{\sigma}_{x,y}=11.86,59.6 [/math] |
[math]{\sigma}_{x,y}=12.2,57.4 [/math] |
[math]{\sigma}_{x,y}=13.0,55.0 [/math] |
[math]{\sigma}_{x,y}= 13.5 \pm 2.7 , 57.8 \pm 2.9 [/math]
|
20 |
[math]{\sigma}_{x,y}= 13.29,60.73[/math] |
[math]{\sigma}_{x,y}= 17.2,56.5[/math] |
[math]{\sigma}_{x,y}= 13.3,59.8[/math] |
[math]{\sigma}_{x,y}= 12.0,60.68[/math] |
[math]{\sigma}_{x,y}= 12.84,63.72[/math] |
[math]{\sigma}_{x,y}=14.0,59.3 [/math] |
[math]{\sigma}_{x,y}= 13.7,61.2[/math] |
[math]{\sigma}_{x,y}= 13.8 \pm 1.5 , 60.3 \pm 2.0 [/math]
|
22 |
[math]{\sigma}_{x,y}=19,61[/math] |
[math]{\sigma}_{x,y}=12,55.7[/math] |
[math]{\sigma}_{x,y}=13.2,61.7[/math] |
[math]{\sigma}_{x,y}=13.3,59.0[/math] |
[math]{\sigma}_{x,y}=11.3,62.4[/math] |
[math]{\sigma}_{x,y}=12.3,60.2[/math] |
[math]{\sigma}_{x,y}=11.9,58.3[/math] |
[math]{\sigma}_{x,y}= 13.3 \pm 2.4 , 59.8 \pm 2.1 [/math]
|
Current -vs- Sigma Data Files
First Scan:
File:HRRL Emitt Current vs Sigma 1stScan x.txt
File:HRRL Emitt Current vs Sigma 1stScan y.txt
Second Scan:
File:HRRL Emitt Current vs Sigma 2ndScan x.txt
File:HRRL Emitt Current vs Sigma 2ndScan y.txt
Current vs Sigma:
X projections:
File:HRRL Emitt Current vs Sigma Projections x.txt
Fit:
P-value of this fit is less than 0.000001.
Y projections:
File:HRRL Emitt Current vs Sigma Projections y.txt
Fit:
P-value of this fit is less than 0.000001.
Next step:
calibrate: mm/pxiel
Parabola: All the x projections makeup one parabola, and y projections makeup one parabola. Put them in together.
Converting pixels to length
Diameter of circle inside crystal is 10 mm.
Convert the pictures to a histogram and measure pixels that way
Figures |
Horizontal Diameter (pixels) |
Vertical Diameter (pixels) |
|
|
91 |
59 |
|
|
90 |
59 |
|
|
90 |
59 |
|
|
90 |
60 |
|
|
90 |
59 |
|
|
91 |
60 |
|
|
90 |
60 |
|
|
Average Horizontal Diameter (pixels) |
Average Vertical Diameter (pixels) |
|
|
[math] 90.29 \pm 0.49 [/math] |
[math] 59.43 \pm 0.53 [/math] |
|
|
Horizontal pixels/mm |
Vertical pixels/mm |
|
|
[math] 9.029 \pm 0.049 [/math] |
[math] 5.943 \pm 0.053 [/math] |
|
|
Horizontal mm/pixels |
Vertical mm/pixels |
|
|
[math] 0.1108 \pm 0.0006 [/math] |
[math] 0.1683 \pm 0.0015 [/math] |
|
Sigma (in mm) vs Dipole Coil Current (on Shunt Resistance)
X Projection
The fit is:
[math] \sigma_x = (2.9098 \pm 0.0073) + (0.21775 \pm 0.00062)I + (0.006696 \pm 0.000047)I^{2} [/math]
p-value is less than 0.000001
For a parabola [math] y = a + bx + cx^{2} [/math], the [math] x [/math] corresponding to the minimum [math] y_{min} [/math] is:
[math] x_{min} = - \frac{b}{2c} [/math].
So, [math] I_{min} = -16.259707[/math]
and
[math] \Delta I_{min} = \sqrt{ \frac{(\Delta b)^2}{4c^2} + \frac{ b^2 (\Delta c)^2}{4c^4} } [/math].
[math] \Delta I_{x,min} = \sqrt{ \frac{(0.00062)^2}{4 \times (0.006696)^2} + \frac{ (0.21775)^2 \times (0.000047)^2}{4 \times (0.006696)^4} } = 0.123161
= 0.12[/math].
[math] I_{min} = -16.26 \pm 0.12 [/math].
[math] \sigma_{x,min} = 2.93671995816274 [/math]
[math] \sigma_{x,min, up} = 2.94409703114234 [/math]
[math] \sigma_{x,min, dn} = 2.92934288518313 [/math]
[math] \sigma_{x,min,up} - \sigma_{x,min} = 0.007377072979601 [/math]
[math] \sigma_{x,min} - \sigma_{x,min,dn}= 0.00737707297960144 [/math]
So,
[math] \sigma_{x,min} = 2.9367 \pm 0.0074 [/math]
Y Projection
The fit is:
[math] \sigma_{y} = (4.691 \pm 0.018) + (-0.3729 \pm 0.0013)I + (0.01289 \pm 0.00008)I^{2} [/math]
p-value is less than 0.000001
[math] x_{min} = - \frac{b}{2c} [/math].
So, [math] I_{min} = 14.464701[/math]
[math] \Delta I_{min} = \sqrt{ \frac{(\Delta b)^2}{4c^2} + \frac{ b^2 (\Delta c)^2}{4c^4} } [/math].
[math] \Delta I_{min} = \sqrt{ \frac{(0.0013)^2}{4 \times (0.01289) ^2} + \frac{ (-0.3729)^2 \times (0.00008)^2}{4 \times (0.01289)^4} } = 0.102966 [/math]
[math] I_{min} = 14.46 \pm 0.10 [/math].
[math] \sigma_{y,min} = 4.65274050365148 [/math]
[math] \sigma_{y,min, up} = 4.67087520809017 [/math]
[math] \sigma_{y,min, dn} = 4.63487351175864 [/math]
[math] \sigma_{y,min, up} - \sigma_{y,min} = 0.0181347044386939 [/math]
[math] \sigma_{y,min} - \sigma_{y,min, dn}= 0.0178669918928378 [/math]
So,
[math] \sigma_{y,min} = 4.653 \pm 0.018 [/math]
Conclusions
For X projection: [math] I_{x,min} = -16.26 \pm 0.12[/math], and [math] \sigma_{x,min} = 2.9367 \pm 0.0074 [/math]
For X projection: [math] I_{y,min} = 14.46 \pm 0.10 [/math], and [math] \sigma_{y,min} = 4.653 \pm 0.018 [/math]
Emittance
Quadrupole Strength: [math] k = 0.2998 \frac{g[T/m]}{GeV} [/math]
g here is the gradient of the qudrupole.
In our case, energy of the beam is 0.01 GeV and gap between dipole center and pole face is 1 inch.
[math] k = 0.2998 \frac{\frac{B(I)}{(1 inch)\times\frac{1 m}{1 inch}}[T/m]}{0.01 GeV} [/math]
[math]B(I) = (3.6 \pm 1.3) \times 10^{-3} + (1945 \pm 2) \times 10^{-5} I [kG] = (3.6 \pm 1.3) \times 10^{-4} + (1945 \pm 2) \times 10^{-6} I [T] [/math]
So,
[math] k = 0.2998 \frac{ (3.6 \pm 1.3) \times 10^{-4} + (1945 \pm 2) \times 10^{-6} I [T] }{0.01 \times 0.0254 [GeV][m]} [/math]
[math] k = (0.42 \pm 0.16) + (2.2956 \pm 0.0024) \times I[/math]
According to File:Emit Meas DAFNE Linac e Beam.pdf, for the case of quadruple scanning one quadrupole and screen, the emittance related to the quadrupole strength.
Transfer Matrix for 1uaruople \tilde{Q} and screen (drift space?) \tilde{S} consist the transfer matrix of the whole system as:
[math] \tilde{M} = \tilde{S}\tilde{Q} [/math]
[math] \tilde{Q} =
\begin{bmatrix}
1 & 0 \\
k=\pm\frac{1}{f} & 1
\end{bmatrix}.
[/math]
[math] \tilde{S} =
\begin{bmatrix}
S_{11} & S_{12} \\
S_{21} & S_{22}
\end{bmatrix}.
[/math]
[math] \sigma_{screen11} = Ak^2 - 2ABk + (C + AB^2) [/math]
[math] \epsilon = \frac{\sqrt{AC}}{S^2_{12}} [/math]
[math] S_{12} [/math] is the distance between quadrupole and screen.
If I have a fit:
[math] \sigma_{screen11} = sk^2 + yk + z [/math]
Then, [math] A=x, B=\frac{y}{-2A}, C=z-AB^2[/math]
Two fits are:
Dr. Kim's Suggestion in his email
from Yujong Kim <yjkim@isu.edu>
to Sadiq Setiniyaz <sadik82@gmail.com>
cc Dr Forest <tforest@athena.physics.isu.edu>
date Fri, Oct 8, 2010 at 6:44 AM
subject Re: Quad Scan Parameters
Dear Sadiq,
Many thanks,
I re-checked your QM scan fitting plot (final plots on emittance mewasurement).
Your fitting range too wide (-20 < k < 50).
Please fit again with a narrower range (+10 < k < 50).
Then, you can get much beautiful results.
Normally, we fit for only one k sign (positive or negative).
Yujong Kim
Here are results after doing Dr. Kim's suggested fit.
Note: I also corrected the distance S12 to the distance between quad center and screen (I originally did from the end of the quad to the screen, this is wrong).
For X projection
Minimum ChiSqrd is: 129.749
The fit is:
sig^2 = (7.82463e-06+-2e-08) + (4.23945e-07+-1e-09)*k + (6.82167e-09+-1e-10)*k*k
Probability of obtaining data at least as incompatible with distribution as the data actually observed is 0.000000
A = 7.82463e-06, B = -0.0270904, C = 1.07925e-09, S12=0.64.
Geometrical Emittance: 2.24354e-07 (m*rad), Normalized Emittance: 4.39048e-06 (m*rad).
Data file contains: Number-of-points B-Field-Strength Error-on-B-Field-Strength Sigma^2 Error-on-Sigma^2
File:HRRL Emit Parbola Fit Xaxis as BfieldStrength.txt
For Y projection
Minimum ChiSqrd is: 25.3174
The fit is:
sig^2 = (1.71755e-05+-8e-08) + (-8.38108e-07+-3e-09)*k + (1.3229e-08+-1e-10)*k*k
Probability of obtaining data at least as incompatible with distribution as the data actually observed is 0.000000
A = 1.71755e-05, B = 0.0243983, C = 3.00479e-09, S12=0.64.
Geometrical Emittance: 5.54629e-07 (m*rad), Normalized Emittance: 1.08538e-05 (m*rad).
Data file contains: Number-of-points B-Field-Strength Error-on-B-Field-Strength Sigma Error-on-Sigma
File:HRRL Emit Parbola Fit Yaxis as BfieldStrength.txt
Data ROOTSYS Fit Script
File:ROOTSCRIPT for HRRL Emittace.C
Emittance Results for HRRL at 10 MeV and 102 micro Amp peak
|
Measurements of the beam spot size as a function of the quadrupole magnetic field used to calculate the beam emittance. The fits are
[math]\sigma^2_x = (7.824\pm 0.02) + (0.424 \pm 0.001)k + (6.8 \pm 0.1 \times 10^{-9} )k^2[/math]
and
[math]\sigma^2_y =17.17 \pm 0.08) - (0.084 \pm 0.003)k + (13.2 \pm 0.1e-10 \times 10^{-9}) k^2[/math] with a \x^2/\nu of
|
File:Emmitance HRRL 1mA 10-14-10.xmgrace.txt
Automatic Script to plot RMS
How does the fit look when using the script below.
Working on it.
You should do background subtraction instead of cutting out the spot.
2 bugs remain till Spe 24th. 1. entries; 2. Sub->Draw();
Running Parabola_Fit_for_AutoRMS.C will run AutoRMS.C and do the fits.
File:AutoRMS.C
File:Parabola Fit for AutoRMS.C
This 2 programs and pictures for data can be downloaded at: [2]
Go back Positrons