Below are the resulting transparency measurements for PbF2 block # 18
12/4/07
- Accelerator Settings
beam energy |
20 MeV
|
Rep Rate: |
30 Hz
|
I_peak: |
60 mA/pulse
|
pulse width: |
0.1 [math]\mu[/math]s (100 ns)
|
beam start: |
10:42
|
beam stop: |
12:42
|
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\times[/math] ns
@10:43
@11:01
@11:16
@11:31
@11:43
@11:53
@11:53
@12:03
@12:13
@12:23
@12:36
Before: After:
- Dose rate measurements (@1255 hours)
[math]\gamma[/math]-radiation |
500 uR/hr
|
[math]\beta[/math]-radiation: |
500 uR/hr
|
- Transparency Measurements (@1525 hours)
12/5/07
- Transparency measurement (1235)
- Accelerator Settings
beam energy |
20 MeV
|
Rep Rate: |
30 Hz
|
I_peak: |
60 mA/pulse
|
pulse width: |
0.1 [math]\mu[/math]s (100 ns)
|
beam start: |
12:54
|
beam stop: |
14:55
|
@ 13:05
- Dose rate measurements (@1457 hours)
[math]\gamma[/math]-radiation |
5 mR/hr
|
[math]\beta[/math]-radiation: |
10 mR/hr
|
Go Back