2NCorr Photon flux estimate
Overview
An estimated lower bound for the photon flux throughout the experiment can be calculated from the data of a D2O target. The measured neutron rate from D2O depends on the following: the (G,n) cross-section as a function of energy, the energy distribution of the brem photons, target geometry, detector efficiency, and photon flux. The (G,n) cross-sections are known and the brem energy distribution can be taken from an MCNP simulation. The only remaining unknown variables are photon flux and detector efficiency. By setting detector efficiency to 100%, and considering only geometric effects (i.e. solid angle), a lower bound can be placed on the photon flux incident on all targets.
Plots
Calculation
The measured neutron rate is given by:
- is the number of photons incident on the target with energy greater than 2.3 MeV, the threshold for photo-disintegration of D2O.
- is photon energy as a function
- is the detector efficiency for D2O photo-neutrons.
- is the probability of a photo-disintegration event given that the photon has energy E.
- is the probability of a photon having energy E, given that the photon is above threshold.
- is the mean number of neutrons observed per pulse.
- is the solid angle, or 0.056/4pi for the entire detector array.
writing
in terms of the cross-section and substituting a normalized photon energy energy distribution taken from MCNP in place of , the above becomes:The unknown detector efficiency can be set to 1, , which forces
to its theoretical minimum.