20min run peak sensing histograms

From New IAC Wiki
Jump to navigation Jump to search

Cathode Voltage Effect on the Peak sensing Spectrum

All the measurements have the same GEM voltage 2.87 kV, just cathode voltage changes.

the figure below shows the the spectrum when the cathode at 3.735 kV (865V higher than the top GEM's voltage), which reaches to the maxmum rate that DAQ can measure.

Date CATH. Voltage (kV) [math]\displaystyle{ \Delta }[/math] V Shutter source run number Notes
10/23 2.870 0 Open off 7916 3h 45min
10/23 2.870 0 Closed off 7917 12h 12min
10/23 2.995 125 Open off 7912
10/23 2.995 125 Closed off 7913
10/25 3.050 Open off 7920 5min
10/25 3.050 Closed off 7926 5min
10/25 3.030 Open off 7921 6min
10/25 3.030 Closed off 7925 5min
10/25 3.000 Open off 7923
10/25 3.000 Closed off 7924
10/23 3.120 250 Open off 7899
10/23 3.120 250 Closed off 7900
10/23 3.245 (redo) 375 Open off 7904
10/23 3.245 375 Closed off 7905
10/23 3.245 375 Open off 7928 21min
10/23 3.245 375 Closed off 7927
10/23 3.370 500 Open off 7908 (22')
10/23 3.370 500 Closed off 7909
10/26 3.735 865 Open off 7933 2k Hz 3 min. rate
10/26 3.735 865 Closed off 7932 0.5-1k Hz 3 min.
10/26 3.585 Open off 7934 1k Hz 123" rate
10/26 3.585 Closed off 7935 0.5k Hz 118".

GEM-2.87 kV CATH-3.435 kV

Date Shutter source run number Scaler counts (Hz) pedestal Integral in ADC full spectrum (Hz) Integral in ADC spectrum beyond pedestal (Hz) notes
10/16 Open off 7847 150+_7 1429/60 7915/60 5810/60
10/16 Closed off 7846 72+_3 1070/60 4029/60 2817/60
10/16 Open off 7848 137+_16 19 129 111
10/16 Closed off 7862 53+_1 7 47 41
10 /16 Open On 7863 147+_12 30 129 101
10/16 Closed On 7864 67+_4 15 59 45
10/17 Open off 7865 132+_14 28 121 97
10/17 Closed off 7866 95+_7 11 59 49
10 /17 Open On 7868 150+_6 32 128 100
10/17 Closed On 7867 74+_4 13 63 52
10/18 Open off 7872 136+_10 9 124 115
10/18 Closed off 7871 51+_3 4 48 44
10 /18 Open On 7869 140+_10 10 123 115
10/18 Closed On 7870 53+_2 4 49 44
10/19 Open off 7873 124+_14 10 114 104
10/19 Closed off 7874 59+_4 5 54 49
10 /19 Open On 7876 141+_8 10 117 108
10/19 Closed On 7875 60+_4 6 55 50
10/20 Open off 7879 129+_16 8 116 108
10/20 Closed off 7880 49+_2 2 45 42
10 /20 Open On 7882 142+_3 8 108 99
10/20 Closed On 7881 53+_2 5 49 44


Test runs

Date Shutter source run number Notes
10/21 open off 7884 5 min separate pedestal from signal
10/20 Closed off 7885 5 min shows a difference.
10/22 open off 7891 5 min CATH 2930 V
10/22 Closed off 7892 5 min CATH 2930 V


10/22 open off 7893 2 min CATH 3435 V
10/22 Closed off 7894 2 min CATH 2435 V
10/23 open off 7898 5 min CATH 3435 V low shutter close rate
10/23 Closed off 7897 5 min CATH 2435 V
10/23 open off 7902 min CATH 3435 V
10/23 Closed off 7901 2 min CATH 2435 V
10/23 open off 7907 2 min CATH 3435 V
10/23 Closed off 7906 2 min CATH 2435 V
10/23 open off 7911 2 min CATH 3435 V
10/23 Closed off 7910 2 min CATH 2435 V
10/23 open off 7915 2 min CATH 3435 V
10/23 Closed off 7914 2 min CATH 2435 V
10/25 open off 7919 3 min CATH 3435 V
10/25 Closed off 7918 3 min CATH 2435 V
10/26 open off 7929 2 min CATH 3435 V
10/26 Closed off 7931 2 min CATH 2435 V
10/26 open off 7937 2 min CATH 3435 V
10/26 Closed off 7936 2 min CATH 2435 V




GO BACK [1]