Rotating Tungsten Target System

From New IAC Wiki
Revision as of 22:31, 28 September 2012 by Setisadi (talk | contribs) (→‎Test)
Jump to navigation Jump to search

Parts

Motor test vedio

HRRL Beam Rot Tar Sys Mot1.png HRRL Beam Rot Tar Sys Mot11.png HRRL Beam Rot Tar Sys Mot7.png HRRL Beam Rot Tar Sys Mot16.png

[More Images ]


Rotary Union

SPS-5510

File:Hrrl-pos-tar-rotary.pdf

HRRL Pos Rotating W Target Sys Parts Roter 1.jpg HRRL Pos Rotating W Target Sys Parts Roter 2.jpg HRRL Pos Rotating W Target Sys Parts Roter 3.jpg HRRL Pos Rotating W Target Sys Parts Roter 4.jpg HRRL Pos Rotating W Target Sys Parts Roter 5.jpg HRRL Pos Rotating W Target Sys Parts Roter 6.jpg

Positron Target Box

Hrrl e+ Target area Space.png


The pipe that go through quads has inner diameter: 47.38 * mm

STR8 - Step Motor Drives

Applied Motion Products motor control.

STR8.png

Power Supply

Power Supply

File:Rotating Tar PS.pdf

STP-PWR-4810 Power supply for stepping systems, dual output with 48 VDC @ 10A (at full load) unregulated and 5 VDC at 0.5A regulated.

120/240 VAC, 50/60 Hz supply voltage, overcurrent protection.

HRRL Beam Rot Tar Sys Mot PS1.png HRRL Beam Rot Tar Sys Mot PS2.png HRRL Beam Rot Tar Sys Mot PS6.png HRRL Beam Rot Tar Sys Mot PS9.png

[More PS Images]

Document

STR8 Documents

STR8 Manuals:

Media:STR_Hardware_Manual.pdf

Media:STR_Quick_Setup_Guide.pdf

Datasheet:

Media:STR_Brochure_925-0002_RevC.pdf

2D Drawing:

Media:STR4_8_drawing.pdf

Media:ST4_8_simple_3D.pdf

Speed-Torque Curves:

Media:STR_speed-torque.pdf

Features

Operates from a 24 to 75 volt DC power supply

Running current up to 7.8 amps per phase

Block Diagram.png

Other Parts needed

1) a 24 to 75 volt DC power supply

2) a source of step signals, such as a PLC or motion controller.

Wire Connection

STR8-Connection.png

STR8-Connection 2.png


Wiring the Motor

Connect the drive to the motor. Four lead motors can be connected in only one way, as shown in Figure 1. We recommend that eight lead motors be connected in parallel, as shown in Figure 2. If using a non-Applied Motion Products motor, please refer to your motor specs for wiring information.

STR8-Connection 3.png

Step Control

Step Pulse Type Most indexers and motion controllers provide motion commands in the “Step and Direction” format. The Step signal pulses once for each motor step and the direction signal commands direction. However, a few PLCs use a different type of command signal: one signal pulses once for each desired step in the clockwise direction (called STEP CW), while a second signal pulses for counterclockwise motion (STEP CCW). The STR drives can accept this type of signal if you remove the drive cover and move jumper S3 from the “1-2” position to the “1-3” position. In STEP CW/STEP CCW mode, the CW signal should be connected to the STEP input and the CCW signal to the DIR input.


Hrrl-pos-tar-motor-puls-cont-step-dir.png


Test

Two Al slabs are place to the disk.

Weight of the Al slab is 235 and 240 grams. Their center of mass are 13 +- 1 cm from the center of disk.

[math]I = \frac{ml^2}{2} = \frac{0.2375~kg \times (0.13~m)^2}{2} = 0.002 ~ kg m^2 [/math]

I was able to rotate these two slabs with with maximum frequencies from the pulser

steps/rev    TTL from pulser      Disk rotation
200          1.4  kHz              7 Hz
200 smooth   1.6  kHz              8 Hz
400          3.2  kHz              8 Hz
400 smooth   3.2  kHz              8 Hz
2000         16.5 kHz              8.25 Hz (TTL frequency increase with small increment.)
5000         40   kHz              8 Hz
20000        164  kHz              8.2

If I go above these these speed, motor stops. To reach highest speed, the TTL pulse should be increased with small increment.

W disk inertia calculation