CHIPS IAC Run 5-29-08
Calibration
Run # | MPA file name | Description |
40 | NaI040.mpa | Na-22 source in front of HpGe and Co-60 on top of NaI detector |
41 | NaI019.mpa | Co-60 source in front of HpGe and Na-22 on top of NaI detector |
Last Dipole Sweep
Tune 10 Mev onto Tungsten and 4 MeV into Cell
We put in two thin pieces (thickness ~1/4" each) making a ~1/2" of lead angled at ~30 degrees wrt vertical between the NaI detector and the collimator to cut down on low-energy (< 200 keV) photons.
Chad Tune
Run # | MPA file name | W | Ta | Description |
45 | NaI045.mpa | IN | IN | Dipole at 2 MeV (0.78 on Pot), 60 Hz rep rate |
46 | NaI046.mpa | IN | IN | Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, 116 | 15 counts at 500 keV, Live=929 seconds
47 | NaI047.mpa | IN | Out | Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, 53 | 9 counts at 500 keV, Live=607 seconds, (Tant IN/Out ratio =116/53 607/929 = 1.4)
48 | NaI048.mpa | IN | Out | Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, 90 | 11 counts at 500 keV, Live=600 seconds, ignore NaI (cable not plugged into scope)
49 | NaI049.mpa | IN | In | Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, 113 | 12 counts at 500 keV, Live=634 seconds,plugged NaI cable back into scope in middle of run. ((Tant IN/Out ratio =113/90 = 1.26 )
Accelerator Gun problem (ground wire shielding was worn away and creating path for short)
Kevin Tune
Restore tune with settings below.:
Device | setting |
RS1 | -14.96 |
RS2 | +0 |
FS1 | 0 |
FS2 | 8.58 |
0Q1 | -14.75 |
0Q2 | +2.26 |
45Q1 | -0.62 |
45Q2 | +1.88 |
L90Q1 | -2.62 |
L90Q2 | +2.83 |
Bend1 | -3.42 |
Bend2 | -5.3 (3 MeV) |
Gun HV | 3 kV |
Grid | 1.64 |
802 | 15.7 kV |
SOL1 | 0 |
SOL2 | 3.58 |
Run # | MPA file name | W | Ta | Description |
56 | NaI056.mpa | IN | In | Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 48 | 8 counts at 500 keV, Live=600 seconds, grid = 1.64, Gun = 3 kV.
57 | NaI057.mpa | IN | Out | Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV, 24 | 6 counts at 500 keV, Live=600 seconds, grid = 1.64, Gun = 3 kV. ( Tant In/out ratio = 2/1)
58 | NaI058.mpa | IN | Out | Dipole at 4 MeV (1.44 on Pot), 300 Hz rep rate, (802 set to 15.7 kV, 25 | 6 counts at 500 keV, Live=600 seconds, grid = 1.64, Gun = 3 kV.
59 | NaI059.mpa | IN | In | Dipole at 4 MeV (1.44 on Pot), 300 Hz rep rate, (802 set to 15.7 kV, 25 | 6 counts at 500 keV, Live=600 seconds, grid = 1.64, Gun = 3 kV.
60 | NaI060.mpa | IN | In | Dipole at 3 MeV (1.44 on Pot), 300 Hz rep rate, (802 set to 15.7 kV, 27 | 6 counts at 500 keV, Live=600 seconds, grid = 1.64, Gun = 3 kV.
61 | NaI061.mpa | IN | In | Dipole at 3 MeV (1.44 on Pot), 300 Hz rep rate, (802 set to 15.7 kV, Permanent sweeper magnet upstream of last quad. | 6 counts at 500 keV, Live=600 seconds, grid = 1.64, Gun = 3 kV.