Signals were observed in the LDS on the Mini DC prottype detector.

The apparatus

File:Minim

The following Voltages were established on the Driftcahmbers wires

Distance HV settings
Wire Volts
Sense 1800
Field -750
Guard 750

The Scintillator mounted on top of the Chamber was set to -900 Volts

MiniChamber CosmicCoincidence 10-9-07.jpg

Noise Level Measured by scope in infinite persistance mode indicate that the Mini Prototype with plastic feedthroughs (Plastica) has noise levels spanning +/- 10 mV. A PMT connected to a scintillator shows noise levels around+/- 2.5 mV.


PlasticaNoise 10-9-07.jpg


A few Characteristic scope pictures of event triggered on the chamber output.