Difference between revisions of "201309 R1ProgressRep"

From New IAC Wiki
Jump to navigation Jump to search
Line 32: Line 32:
  
 
#discovered current draw beyond 20 uA when Sector 1 HV_SL1 board 7 voltage is raising to 500 volts.  need to debug
 
#discovered current draw beyond 20 uA when Sector 1 HV_SL1 board 7 voltage is raising to 500 volts.  need to debug
 +
The board drags a high current, all the boots were removed and the current is 15 uA for field, 12 uA for guard, and 1  um for sense as the applied voltage  on them is 35V, 10V,50V successively.
 +
 
#replaced Sector 1 HV_SL1 board 4 due to a broken bus pin
 
#replaced Sector 1 HV_SL1 board 4 due to a broken bus pin
 
#continue burning in Sector 5
 
#continue burning in Sector 5

Revision as of 17:35, 22 September 2013

09/04/13

Replaced 10 clean room filters


Tasks remaining:

  1. Measure all Field and Sense wire tensions prior to potting
  2. pot S2 & S3
  3. install Windows on S2 & S3
  4. install HVBs & STBs onto S2 & S3
  5. burn in S2 & S3
  6. finish Q&A on all chambers


David Coneff is managing two student workers and plans to finish the above remaining tasks before Jan 2014 as a part time worker, their work schedule is given below.


Mon Tues Wed Thurs Fri Sat Sun
1-5pm 1-5pm 1-5pm 11am-5pm

9/20/13

Q&A tasks remaining

  1. discovered current draw beyond 20 uA when Sector 1 HV_SL1 board 7 voltage is raising to 500 volts. need to debug

The board drags a high current, all the boots were removed and the current is 15 uA for field, 12 uA for guard, and 1 um for sense as the applied voltage on them is 35V, 10V,50V successively.

  1. replaced Sector 1 HV_SL1 board 4 due to a broken bus pin
  2. continue burning in Sector 5
  3. finish taking scope pictures of sense wire output on Sector 5
  4. continue debugging TDC input cables

CLAS12_R1_Progress_Reports#September_2013