|5829 || Coincidence, Au+sand+crucible #5 , 200 ns Coincidence window, no TDC  hrs,  min  sec long, 23 Hz, '''Det B HV ON''', ROC crashed after 45 hours 28 minutes, 285302 events recorded, scaler says 199440 seconds for run time=> 55 hours, I think the run lasted 2 hours assuming a 40 Hz counting rate and 285302 events
 
|5829 || Coincidence, Au+sand+crucible #5 , 200 ns Coincidence window, no TDC  hrs,  min  sec long, 23 Hz, '''Det B HV ON''', ROC crashed after 45 hours 28 minutes, 285302 events recorded, scaler says 199440 seconds for run time=> 55 hours, I think the run lasted 2 hours assuming a 40 Hz counting rate and 285302 events
 
|-
 
|-
|5830 || Coincidence, Au Foil, only counting with detector 180-3 (no TDC)  35 min 6 sec long, 90Hz, '''Det B HV OFF''', Det B Coincidence window was more than 400 nsec
+
|5831 || Coincidence, Au Foil, only counting with detector 180-3 (no TDC)  35 min 6 sec long, 90Hz, '''Det B HV OFF''', Det B Coincidence window was more than 400 nsec
 +
|-
 +
|5832 || OR, Au Foil, only counting with detector 180-3 (no TDC)  35 min 6 sec long, 16 kHz, '''Det B HV OFF''',Too hot for current setup
 
|-
 
|-
 
|}
 
|}
  
 
[[PAA_CoincidenceCounting#8.2F22.2F13_Activation]]
 
[[PAA_CoincidenceCounting#8.2F22.2F13_Activation]]

Revision as of 17:09, 26 August 2013

Au-196 #5 irradiation

The link below will take you to an analysis of the photon spectrum observed when a mixture of Au + San in a crucible is irradiated for 1 hour using a 44 MeV, 2kW electron beam incident on a 4 mm W converter

Au-196_5-08-22-13


The link below will take you to the 0.002" thick gold foil measurements

Barium Oxide BaO

BO-08-22-13

Y-88 foil

Y88-08-22-13

Nickel normalization foils

Ni-08-22-13

runlist

Run Description
5786 21 min, 6 sec
5790 Ba-133 source, TDC not getting hits
5791 Ba-133 source , TDC not getting hits
5792 Ba-133 source, TDC not getting hits
5817 Gold foils, only counting with detector 180-3 (no TDC) 8 min 2 sec long, 556 Hz
5818 Ni foil F1, only counting with detector 180-3 (no TDC) 6 min 31 sec long, 399 Hz
5819 Ni foil B1, only counting with detector 180-3 (no TDC) 7 min 36 sec long, 417 Hz
5820 empty, only counting with detector 180-3 (no TDC) 8 min 18 sec long, 396 Hz
5821 Ba-132, only counting with detector 180-3 (no TDC) 6 min 1 sec long, Hz

Due to the low rates we reconfigured the setup putting the two detectors closer together


Run Description
5822 Ba-132 + Al rod, only counting with detector 180-3 (no TDC) 10 min 56 sec long, 459 Hz
5823 empty rod, only counting with detector 180-3 (no TDC) 11 min 49 sec long, 439 Hz
5825 Y-88, only counting with detector 180-3 (no TDC) 19 min 7 sec long, 500 Hz
5826 Au-196, only counting with detector 180-3 (no TDC) 8 min 38 sec long, 1096Hz
5827 sand+crucible, only counting with detector 180-3 (no TDC) 8 min 10 sec long, 989Hz
5828 Coincidence, sand+crucible, only counting with detector 180-3 (no TDC) 15 hrs, 4 min 21 sec long, 47Hz, Det B HV OFF, Det B Coincidence window was more than 400 nsec
5829 Coincidence, Au+sand+crucible #5 , 200 ns Coincidence window, no TDC hrs, min sec long, 23 Hz, Det B HV ON, ROC crashed after 45 hours 28 minutes, 285302 events recorded, scaler says 199440 seconds for run time=> 55 hours, I think the run lasted 2 hours assuming a 40 Hz counting rate and 285302 events
5831 Coincidence, Au Foil, only counting with detector 180-3 (no TDC) 35 min 6 sec long, 90Hz, Det B HV OFF, Det B Coincidence window was more than 400 nsec
5832 OR, Au Foil, only counting with detector 180-3 (no TDC) 35 min 6 sec long, 16 kHz, Det B HV OFF,Too hot for current setup

PAA_CoincidenceCounting#8.2F22.2F13_Activation