A sharp drop on the positron distribution occurred for the region y is between -25.8 mm and -27.2 mm, which makes a 1.4 mm wide strip.
The Y-position distribution of the beam shown in Figure XXXX has a sharp drop in the region between -25.8 mm and -27.2 mm.  , which makes a 1.4 mm wide strip.


The distance from the back of T1 to the detector is 25.8 mm. DDNT1T1 is 1.016 mm thick, and the projected thickness of T1's thickness on the detector DDNT1 is 1.4 mm (<math>1.016 \sqrt{2}=1.44</math>).
The distance from the back of T1 to the detector is 25.8 mm. DDNT1T1 is 1.016 mm thick, and the projected thickness of T1's thickness on the detector DDNT1 is 1.4 mm (<math>1.016 \sqrt{2}=1.44</math>).

Revision as of 22:23, 24 April 2013

In G4beamline manual "The electromagnetic processes of these physics lists are advertised to be valid above a few hundred electron Volts; Geant4 has a set of low energy electromagnetic processes, indicated by a suffix “_EMX” in the physics list name."

2 MeV Positrons

Measured Electron energy distribution at 10 MeV on 1.mm target

Simulation steps

1.) GEANT4 Simulated Beam energy distribution


2.) GEANT4 Simulated Positrons emitted from 1.x mm thick target


3.) Now use above Positron distribution as the particle source for G4beamline

Positrons hitting Tungsten Converter target

4.) Use GEANT4 to determine 511s from the positrons distribution impinging converter target

Oct 16th 2012 BenchMark

stages:

1. Program to input emittance, output beamsize, beam, divergence and beam energy.

2. e- on W, outcome e+. Incident electron distribution on T1. with general particle source with step 1 histogram. check graph x, y, z theta, En_dis out_put is the input. (directory for each).

3. insert T1 and generate positron distribution.

4. Acceleractor code to transport positron along the beamline. Out put positron theta, beamsize (x,y), energy distribution, out puts transported positron.

5. Geant4 takes step 4 output generates gamma (and other e+,e-) and look at those goes to detectors. beamline, plus shielding, and detectors.

Simulations

Partical Data Ground ID: PDGid=11 is electron. PDGid=-11 is positron. PDGid=22 is photon.

Parameters

Dipole vacuum chamber width is [math]\displaystyle{ 17 \pm 0.5 }[/math] mm

The cavity exit diameter is about 7.3 mm.


Energy Spread Two Skewed Gaussian Fit

Energy spread fitted with two skewed Gaussian.

Beam Distributions Beyond RMS: Media:Beam_Distributions_Beyond_RMS.pdf

Amplitude = 2.13894, mean = 12.07181, sigma_L = 4.46986, sigma_R = 1.20046

Sigma = 2.83516, Es = -0.57658

rms = 2.56472, skew = -0.94853


Amplitude2 = 10.88318, mean2 = 12.32332, sigma_L2 = 0.69709, sigma_R2 = 0.45170

Sigma2 = 0.57440, Es2 = -0.21360

rms2 = 0.56719, skew2 = -0.34231


Electron Distribution Upstream and Positron Distribution Downstream of Target1

simulation: Electron Distribution Upstream and Positron Distribution Downstream of Target1

3067274 Electrons fired.

T1_s=943.5

FDT1_s=$T1_s-26.52

BDT1_s=$T1_s+26.52

Thickness of T1 is 1.016 mm, radius of T1 is 15.875 mm (0.625 inches).


Step 1: Generating positron from electron beam

Detector is after T1 to saple positron distribution. 1,379,974,500 electrons shot at the tungsten target to generate positrons.

step 1: ratio

DDNT1 = Detector DowN from T1

DQ4 = Detector at entrance Quad 4 located right after T1

DD1 = Detector at entrance of the first Dipole.

e-(DDT1)/e+(DDNT1) = 1248

e-(DDT1)/e+(DQ4) = 123698

e-(DDT1)/e+(DD1) = 936846


e+(DDNT1)/e+(DQ4) = 99

e+(DDNT1)/e+(DD1) = 750


e+(DQ4)/e+(DD1) = 7.6

Step 1: Generated Beam on DDNT1

Detector down T1:

Positrons on detector right before Q4.

X profile

Y profile (why is the distribution clipped on the left side in the figure)


X divergence profile

Y divergence profile

Momentum distribution

Momentum distribution

Sharp drop issue

The Y-position distribution of the beam shown in Figure XXXX has a sharp drop in the region between -25.8 mm and -27.2 mm. , which makes a 1.4 mm wide strip.

The distance from the back of T1 to the detector is 25.8 mm. DDNT1T1 is 1.016 mm thick, and the projected thickness of T1's thickness on the detector DDNT1 is 1.4 mm ([math]\displaystyle{ 1.016 \sqrt{2}=1.44 }[/math]).

The positrons created in the T1 has small probability to make to the strip area, because they need to travel through thick tungsten in that direction. Only the few positrons created on the lower edge of the T1 can make to the strip area. The positrons observed for y < -27.2 mm are the positrons passed through the upstream side of the T1.

Cut off line is around 26.5 mm corresponding to the large angle.



DDNT1 is at 26.52 mm (53.04 mm)downstream of T1.

T1 radius is 25.4 mm (d=50.8 mm)

DDNT1 radius is 31.75 mm (d=63.5 mm).



Step 1: Generated Beam on DQ4

Positrons on detector right before Q4.

X profile

Y profile

X divergence profile

Y divergence profile

Momentum distribution

Momentum distribution

Step 1: Generated Beam on DD1

Positrons on detector right before D1 - first dipole.

X profile

Y profile

X divergence profile

Y divergence profile

Momentum distribution

Momentum distribution

Step 2: generate positron

The positrons after T1 is detected on a virtual detector. The positrons beam size, divergence and momentum distributions are extracted and created new positron beam.

Generate positron beam from the detector after T1 and transport it to right before D1.

221032400*16=3,536,518,400 positrons generated.

step 2: ratio

e+(DDNT1)/e+(DQ4) = 3536518400/47788670 = 74

e+(DDNT1)/e+(DD1) = 3536518400/5464220 = 647

e+(DQ4)/e+(DD1) = 8.7

Generated Beam on DQ4

Positrons on detector right before Q4.

X profile

Y profile

X divergence profile

Y divergence profile

Momentum distribution

Momentum distribution


Generated Beam on DD1

Positrons on detector right before D1 - first dipole.

X profile

Y profile

X divergence profile

Y divergence profile

Momentum distribution

Momentum distribution

Beam Compare Step1 and Step2

Compare Ratio

S1 S2
e-(DDT1)/e+(DDNT1) 1248
e-(DDT1)/e+(DQ4) 123698
e-(DDT1)/e+(DD1) 936846
e+(DDNT1)/e+(DQ4) 99 74
e+(DDNT1)/e+(DD1) 750 647
e+(DQ4)/e+(DD1) 7.6 8.7

Positrons at DDNT1

Step 1 Step 2
X profile
Y profile
X divergence profile
Y divergence profile
Momentum distribution
Momentum distribution


Compare at DQ4

Step 1 Step 2
X profile
Y profile
X divergence profile
Y divergence profile
Momentum distribution
Momentum distribution

Compare at DD1

Step 1 Step 2
X profile
Y profile
X divergence profile
Y divergence profile
Momentum distribution
Momentum distribution