Line 100: | Line 100: | ||
| Energy Switch || In (Low En Range) | | Energy Switch || In (Low En Range) | ||
|- | |- | ||
− | | Solenoid 1 || | + | | Solenoid 1 || 6.9 A |
|- | |- | ||
− | | Solenoid 2 || | + | | Solenoid 2 || 9.3 A |
|- | |- | ||
− | | Gun Hor || 0. | + | | Gun Hor || -0.1 A |
|- | |- | ||
− | | Gun Ver || 0 | + | | Gun Ver || 0 A |
|- | |- | ||
− | |Output Hor || | + | |Output Hor || 0.5 A |
|- | |- | ||
− | | Output Ver || 0 A | + | | Output Ver || 0.3 A |
|- | |- | ||
| Rep Rate || 10 | | Rep Rate || 10 | ||
Line 118: | Line 118: | ||
| Gun Grid Voltage || 10(Knob Setting) | | Gun Grid Voltage || 10(Knob Setting) | ||
|- | |- | ||
− | | RF frequency ||2856. | + | | RF frequency ||2856.780 MHz |
|- | |- | ||
− | | Modulator HV Power Supply || 3. | + | | Modulator HV Power Supply || 3.71 (Knob Setting) |
|- | |- | ||
| RF macro Pulse Length (FWHM) || 300 ns | | RF macro Pulse Length (FWHM) || 300 ns | ||
Line 134: | Line 134: | ||
|Q5 (A)|| 0 | |Q5 (A)|| 0 | ||
|- | |- | ||
− | |Q6 (A)|| | + | |Q6 (A)|| 0 |
|- | |- | ||
|} | |} |
Revision as of 21:19, 11 July 2012
Goals
measure the Beam spot size on target
Measure the Transmission
1st Tuning
Energy Switch | Out (High En Range) |
Solenoid 1 | 12 A |
Solenoid 2 | 10.5 A |
Gun Hor | 0 A |
Gun Ver | 0 A |
Output Hor | 0 A |
Output Ver | 0.5 A |
Rep Rate | 10 |
Gun HV | 10 (Knob Setting) |
Gun Grid Voltage | 10(Knob Setting) |
RF frequency | 2856.268 MHz |
Modulator HV Power Supply | 4.2 (Knob Setting) |
RF macro Pulse Length (FWHM) | 300 ns |
Q1 (A) | 0 |
Q2 (A) | 0 |
Q3 (A) | 0 |
Q4 (A) | 0 |
Q5 (A) | 0 |
Q6 (A) | 0 |
2nd Tuning
Energy Switch | In (Low En Range) |
Solenoid 1 | 3.0 A |
Solenoid 2 | 5.2 A |
Gun Hor | 0.1 A |
Gun Ver | 0.1 A |
Output Hor | -0.1 A |
Output Ver | -0.3 A |
Rep Rate | 10 |
Gun HV | 10 (Knob Setting) |
Gun Grid Voltage | 10(Knob Setting) |
RF frequency | 2856.269 MHz |
Modulator HV Power Supply | 4.13 (Knob Setting) |
RF macro Pulse Length (FWHM) | 300 ns |
Q1 (A) | 0 |
Q2 (A) | 0 |
Q3 (A) | 0 |
Q4 (A) | 0 |
Q5 (A) | 0 |
Q6 (A) | 0 |
3rd Tuning
Energy Switch | In (Low En Range) |
Solenoid 1 | 6.9 A |
Solenoid 2 | 9.3 A |
Gun Hor | -0.1 A |
Gun Ver | 0 A |
Output Hor | 0.5 A |
Output Ver | 0.3 A |
Rep Rate | 10 |
Gun HV | 10 (Knob Setting) |
Gun Grid Voltage | 10(Knob Setting) |
RF frequency | 2856.780 MHz |
Modulator HV Power Supply | 3.71 (Knob Setting) |
RF macro Pulse Length (FWHM) | 300 ns |
Q1 (A) | 0 |
Q2 (A) | 0 |
Q3 (A) | 0 |
Q4 (A) | 0 |
Q5 (A) | 0 |
Q6 (A) | 0 |