Difference between revisions of "2012AnnihCountrRateEstimate"
		
		
		
		
		
		Jump to navigation
		Jump to search
		
				
		
		
	
| Line 45: | Line 45: | ||
| + | ===Chromox target === | ||
| + | |||
| + | [[File:Chromox_datasheet_CERN.pdf]] | ||
| [[PePPO_2012Run]] | [[PePPO_2012Run]] | ||
Revision as of 17:31, 20 January 2012
Rate Estimates
Previous experiment at the IAC
|  |  |   | 
| IAC apparatus for positron production experiment | Counts observed when the dipole is tuned to direct positrons onto the Ta target | Counts from electrons on Ta target | 
- HpGe observed about 1 annihilation photon per 10 microCoulombs of electrons on the upstream Tungsten target
- Ratio of annihilation photons observed when using positrons to electrons 120 to 10
| Condition | Grade Calculation | 
| Electron Beam Energy | 10 MeV | 
| Peak current | 40 mA | 
| Pulse width | 100 ns | 
| Rep Rate | 300 Hz | 
NaI rate Ratio of positron to electron beam
Assumed Geometry
Assume a 2 mm thick Tungsten target that is 1" square
The target is located at -80 < Z < -80.2
The NaI crystal is 2.32" or 56.49 mm in diameter
The NaI crystal is 8" from the target then the opening angle is atan(2.32/8/2) = 8.25 degrees