Sadiq, | |||
You require 55 – 100 psig into the solenoid. Applying 24 VDC to the solenoid will open the valve and removing it will close the valve. | |||
Your valve is a normally closed valve, meaning it is spring closed. Reference the part number in the manual that ends in 41. | |||
Give me a call If you have any questions. | |||
Regards, | |||
Bill McPheeters | |||
VAT Sales Engineer - Austin, TX | |||
T: 512-280-8050, F: 512-280-8054 | |||
Revision as of 23:12, 4 May 2011
Mini UHV gate valve
Valve with pneumatic actuator:
single acting with closing spring (NC)
ISO-KF and CF-F
Manual: File:Mini UHV gate valve Manual.pdf
Leak rate: body / valve seat: [math]\displaystyle{ < 5 \times 10^{-10}/ < 1 \times 10^{-9}~mbar~Is^{-1} }[/math]
Pressure range: [math]\displaystyle{ 1 \times 10{-10} }[/math] mbar to 2 bar (abs)
1 millibar = 0.750061683 torr = 0.75 torr
Sadiq, You require 55 – 100 psig into the solenoid. Applying 24 VDC to the solenoid will open the valve and removing it will close the valve. Your valve is a normally closed valve, meaning it is spring closed. Reference the part number in the manual that ends in 41. Give me a call If you have any questions. Regards, Bill McPheeters VAT Sales Engineer - Austin, TX T: 512-280-8050, F: 512-280-8054