Operating Voltage Study

We will lower the operating voltage and take scope pictures to determine the operating point for the mini chamber.


SenseWire 1

Preamplifier voltage was set to 5.9 Volts.

Sense Wire HV (Volts) Field Wire HV (Volts) Scope Image
1700 -850 SenseWire1 1700V Cosmic 10-12-07.jpg


Back to Mini Prototype page

Sense wire 2

Preamplifier voltage was set to 5.9 Volts. We saw a lot of noise ( 40 mV peak to peak) when increasing the preamp voltage from 2.2 V to 5.7 Volts. After 5.7 volts the noise when back to a noise level of 8 mV peak to peak which is smaller than the 16 mV peak to peak noise observed 3 days ago on the sense wire (capacitor side)before the preamp.


Sense Wire HV (Volts) Field Wire HV (Volts) Scope Image
1700 -850 SenseWire2 1700V Cosmic 10-12-07.jpg 1690 -845 200 px