Difference between revisions of "MiniDC Signals 10-0-07"
Jump to navigation
Jump to search
Line 3: | Line 3: | ||
The apparatus | The apparatus | ||
− | [[Image: | + | [[Image:MiniChamber_Setup_10-9-07.jpg | 200 px]] |
The following Voltages were established on the Driftcahmbers wires | The following Voltages were established on the Driftcahmbers wires | ||
Line 33: | Line 33: | ||
[[Image:MiniChamber_Singles_A_10-9-07.jpg | 400 px]] | [[Image:MiniChamber_Singles_A_10-9-07.jpg | 400 px]] | ||
+ | |||
+ | [[Image:MiniChamber_Singles_B_10-9-07.jpg | 400 px]] | ||
+ | |||
+ | [[Image:MiniChamber_Singles_C_10-9-07.jpg | 400 px]] | ||
+ | |||
+ | [[Image:MiniChamber_Singles_D_10-9-07.jpg | 400 px]] | ||
+ | |||
+ | [[Image:MiniChamber_Singles_E_10-9-07.jpg | 400 px]] | ||
+ | |||
+ | [[Image:MiniChamber_Singles_F_10-9-07.jpg | 400 px]] | ||
+ | |||
+ | [[Image:MiniChamber_Singles_G_10-9-07.jpg | 400 px]] | ||
+ | |||
+ | |||
[http://www.iac.isu.edu/mediawiki/index.php/Mini-prototype Back to MiniPrototype Page] | [http://www.iac.isu.edu/mediawiki/index.php/Mini-prototype Back to MiniPrototype Page] |
Revision as of 23:44, 9 October 2007
Signals were observed in the LDS on the Mini DC prottype detector.
The apparatus
The following Voltages were established on the Driftcahmbers wires
Distance | HV settings | |
Wire | Volts | |
Sense | 1800 | |
Field | -750 | |
Guard | 750 |
The Scintillator mounted on top of the Chamber was set to -900 Volts
Noise Level Measured by scope in infinite persistance mode indicate that the Mini Prototype with plastic feedthroughs (Plastica) has noise levels spanning +/- 10 mV. A PMT connected to a scintillator shows noise levels around+/- 2.5 mV.
A few Characteristic scope pictures of event triggered on the chamber output.