CH PAS He3 BorAl Attenuation Study: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Harpconn (talk | contribs)
Harpconn (talk | contribs)
Line 7: Line 7:
|  Run Number || Configuration || Discriminator Threshold (mV) || Cf-252 Button Source || Counts || Run Time (Sec) || Count Rate (Hz) || Uncertainty
|  Run Number || Configuration || Discriminator Threshold (mV) || Cf-252 Button Source || Counts || Run Time (Sec) || Count Rate (Hz) || Uncertainty
|-
|-
|  1  || Detector on poly at +1250V || 255 || No ||  || 600 ||  ||  
|  1  || Detector on BorAl at +1250V || 255 || No ||  || 600 ||  ||  
|-
|-
|  2  || Detector on poly at +1250V || 255 || No ||  || 600 ||  ||
|  2  || Detector on BorAl at +1250V || 255 || No ||  || 600 ||  ||
|-
|-
|  3  || Detector on poly at +1250V || 255 || No ||  || 600 ||  ||
|  3  || Detector on BorAl at +1250V || 255 || No ||  || 600 ||  ||
|-
|-
|  4  || Detector on poly at +1250V || 255 || No ||  || 600 ||  ||
|  4  || Detector on BorAl at +1250V || 255 || No ||  || 600 ||  ||
|-
|-
|  5  || Detector on poly at +1250V || 255 || No ||  || 600 ||  ||
|  5  || Detector on BorAl at +1250V || 255 || No ||  || 600 ||  ||
|-
|-
|}
|}

Revision as of 21:45, 25 June 2021

Background Measurements

1250V Source Out Data
Run Number Configuration Discriminator Threshold (mV) Cf-252 Button Source Counts Run Time (Sec) Count Rate (Hz) Uncertainty
1 Detector on BorAl at +1250V 255 No 600
2 Detector on BorAl at +1250V 255 No 600
3 Detector on BorAl at +1250V 255 No 600
4 Detector on BorAl at +1250V 255 No 600
5 Detector on BorAl at +1250V 255 No 600












CH He3 Attenuation Measurements