Difference between revisions of "Comparison of GEANT Simulation to Whitney Data"
Jump to navigation
Jump to search
Line 12: | Line 12: | ||
|- | |- | ||
| Simulation || GEANT4(1cm target) ||GEANT4(1cm target)|| GEANT4(5cm target) || Whitney | | Simulation || GEANT4(1cm target) ||GEANT4(1cm target)|| GEANT4(5cm target) || Whitney | ||
+ | |- | ||
+ | | Individual Moller Cross-Section (b) || 5.95e-7 || 5.94e-8 || 7.87e-8 ||7.88e-8 | ||
|- | |- | ||
| Event Cross-Section (b) || 0.61 || 0.61|| 0.38 || 0.079 | | Event Cross-Section (b) || 0.61 || 0.61|| 0.38 || 0.079 |
Revision as of 17:07, 26 March 2018
Simulation | GEANT4(1cm target) | GEANT4(1cm target) | GEANT4(5cm target) | Whitney |
Individual Moller Cross-Section (b) | 5.95e-7 | 5.94e-8 | 7.87e-8 | 7.88e-8 |
Event Cross-Section (b) | 0.61 | 0.61 | 0.38 | 0.079 |
Moller Cross-Section (b) | 0.58 | 0.58 | 0.361 | 0.075 |
Length of Target (cm) | 1 | 1 | 5 | 5 |
t_{simulated} (s) | 1.3E-5 | 1.3E-4 | 9.8E-4 | 9.54E-5 |
N_{events} | 1026940 | 10270829 | 4826141 | 1001700 |
N_{Moller} | 975593 | 9757288 | 4584834 | 951138 |
N_{incident} | 4E7 | 4E8 | 6E7 | 6E7 |
Total dectector events occur for about 2.5% of the incident electrons on a LH2 target. We can assume that the Moller rate is 95% of the total event rate. We can assume the number of Moller events that occur within the DC range to be around 30% of the total Moller events occuring for the number of incident electrons for LH2 as well. Since the differential cross-section over the angel theta is proportional to the differtial cross-section over wire number we can dividing the Moller differential cross-section by the product of the density and length of the target material