Difference between revisions of "11-11-2016"
Jump to navigation
Jump to search
Line 36: | Line 36: | ||
|- | |- | ||
|5461 ||-||Th || 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V , ''' No beam dump removed poly''' Th target, | |5461 ||-||Th || 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V , ''' No beam dump removed poly''' Th target, | ||
+ | |- | ||
+ | |5462 ||-||Th || 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V , No beam dump removed poly' Th target, Added 2" thick Aluminum hardener downstream of sweep magnet | ||
|} | |} | ||
Revision as of 23:56, 11 November 2016
Runlist
Horizontal accelerator side collimator 7 mm, horizontal cell side 19 mm. 3 in of Pb on D30 & D330, 2 in of Pb on upstream side of D210, wax in front of Pb on wall downstream of beam dump
Summary
ToF spectrum for 30, 40 50 and 70 mV thresholds.
Blinder width study
Blinder as a photon source