Difference between revisions of "G4Beamline PbBi"
Jump to navigation
Jump to search
Line 28: | Line 28: | ||
meanMomentum=10. sigmaE=0. maxR=10. | meanMomentum=10. sigmaE=0. maxR=10. | ||
</pre> | </pre> | ||
+ | |||
+ | Incident Electron spatial distribution and energy | ||
+ | |||
+ | [[File:PbBi_5-1-15_X-Yposition.png | 200 px]][[File:PbBi_5-1-15_Ein.png | 200 px]] | ||
+ | |||
+ | Positron and Electron Momentum after the converter | ||
+ | |||
+ | [[File:PbBi_5-1-15_Ppositron.png | 200 px]][[File:PbBi_5-1-15_Pelectron.png | 200 px]] | ||
{| border="1" | {| border="1" |
Revision as of 17:06, 1 May 2015
Development of a Positron source using a PbBi converter and a Solenoid
Converter target properties
Definition of Lead Bismuth
1cm diameter target
2 mm thick PbBi
0.5 Tesla solenoid
G4BeamLine and MCNPX
Target thickness optimization
PbBi_THickness_GaussBeam
2mm thick PbBi, 10 MeV, 1 cm cylindrical incident electron distribution
G4beamline pencil beam 10 cm radius
beam ellipse particle=e- nEvents=1000000 beamZ=0.0 beamX=0. beamY=0. \ sigmaX=10.0 sigmaY=10.0 sigmaXp=0.000 sigmaYp=0.000 \ meanMomentum=10. sigmaE=0. maxR=10.
Incident Electron spatial distribution and energy
Positron and Electron Momentum after the converter
PbBi Thickness (mm) | #positrons/million electrons (G4Beamline) | #positrons/million electrons (MCNPX) |
1 | 1091 | |
1.5 | 1728 | |
2 | 1902,1921 | 431984 |
2.5 | 2062 | |
3 | 13 | 1986 |
3.5 | 1938 | |
4 | 39 | 1858 |
5 | 1646 | |
6 | 37 | 1541 |
10 | 1216 |
2mm thick PbBi, 10 MeV, point source
G4beamline pencil beam 10 cm radius
beam ellipse particle=e- nEvents=1000000 beamZ=0.0 beamX=0. beamY=0. \ sigmaX=10.0 sigmaY=10.0 sigmaXp=0.000 sigmaYp=0.000 \ meanMomentum=10. sigmaE=0. maxR=10.
PbBi Thickness (mm) | #positrons/million electrons (G4Beamline) | #positrons/million electrons (MCNPX) |
1 | 1091 | |
1.5 | 1728 | |
2 | 1902 | 431984 |
2.5 | 2062 | |
3 | 13 | 1986 |
3.5 | 1938 | |
4 | 39 | 1858 |
5 | 1646 | |
6 | 37 | 1541 |
10 | 1216 |