20min run peak sensing histograms: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Foretony (talk | contribs)
Foretony (talk | contribs)
Line 20: Line 20:
| 10/23||3.120  ||250 || Closed || off || 7900||
| 10/23||3.120  ||250 || Closed || off || 7900||
|-
|-
|10/23|| 3.245 || 375|| Open ||off || 7904|| [[File:CATH3.245_GEM2.87_7905c_7904.png |100px ]]
|10/23|| 3.245 (redo) || 375|| Open ||off || 7904|| [[File:CATH3.245_GEM2.87_7905c_7904.png |100px ]]
|-
|-
| 10/23||3.245  || 375|| Closed || off || 7905||
| 10/23||3.245  || 375|| Closed || off || 7905||

Revision as of 17:21, 24 October 2014

Cathode Voltage Effect on the Peak sensing Spectrum

All the measurements have the same GEM voltage 2.87 kV, just cathode voltage changes.


Date CATH. Voltage (kV) [math]\displaystyle{ \Delta }[/math] V Shutter source run number Notes
10/23 2.870 0 Open off 7916 3h 45min
10/23 2.870 0 Closed off 7917 12h 12min
10/23 2.995 125 Open off 7912
10/23 2.995 125 Closed off 7913
10/23 3.120 250 Open off 7899
10/23 3.120 250 Closed off 7900
10/23 3.245 (redo) 375 Open off 7904
10/23 3.245 375 Closed off 7905
10/23 3.370 500 Open off 7908 (22')
10/23 3.370 500 Closed off 7909

GEM-2.87 kV CATH-3.435 kV

Date Shutter source run number Scaler counts (Hz) pedestal Integral in ADC full spectrum (Hz) Integral in ADC spectrum beyond pedestal (Hz) notes
10/16 Open off 7847 150+_7 1429/60 7915/60 5810/60
10/16 Closed off 7846 72+_3 1070/60 4029/60 2817/60
10/16 Open off 7848 137+_16 19 129 111
10/16 Closed off 7862 53+_1 7 47 41
10 /16 Open On 7863 147+_12 30 129 101
10/16 Closed On 7864 67+_4 15 59 45
10/17 Open off 7865 132+_14 28 121 97
10/17 Closed off 7866 95+_7 11 59 49
10 /17 Open On 7868 150+_6 32 128 100
10/17 Closed On 7867 74+_4 13 63 52
10/18 Open off 7872 136+_10 9 124 115
10/18 Closed off 7871 51+_3 4 48 44
10 /18 Open On 7869 140+_10 10 123 115
10/18 Closed On 7870 53+_2 4 49 44
10/19 Open off 7873 124+_14 10 114 104
10/19 Closed off 7874 59+_4 5 54 49
10 /19 Open On 7876 141+_8 10 117 108
10/19 Closed On 7875 60+_4 6 55 50
10/20 Open off 7879 129+_16 8 116 108
10/20 Closed off 7880 49+_2 2 45 42
10 /20 Open On 7882 142+_3 8 108 99
10/20 Closed On 7881 53+_2 5 49 44


Test runs

Date Shutter source run number Notes
10/21 open off 7884 5 min separate pedestal from signal
10/20 Closed off 7885 5 min shows a difference.
10/22 open off 7891 5 min CATH 2930 V
10/22 Closed off 7892 5 min CATH 2930 V


10/22 open off 7893 2 min CATH 3435 V
10/22 Closed off 7894 2 min CATH 2435 V
10/23 open off 7898 5 min CATH 3435 V low shutter close rate
10/23 Closed off 7897 5 min CATH 2435 V
10/23 open off 7902 min CATH 3435 V
10/23 Closed off 7901 2 min CATH 2435 V
10/23 open off 7907 2 min CATH 3435 V
10/23 Closed off 7906 2 min CATH 2435 V
10/23 open off 7911 2 min CATH 3435 V
10/23 Closed off 7910 2 min CATH 2435 V
10/23 open off 7915 2 min CATH 3435 V
10/23 Closed off 7914 2 min CATH 2435 V




GO BACK [1]