|Run # || date || Sense HV ||Guard HV || Field HV || Eff W1 || Eff W2 || Eff W3 || Eff W4 || Eff W5 || Eff W6  
 
|Run # || date || Sense HV ||Guard HV || Field HV || Eff W1 || Eff W2 || Eff W3 || Eff W4 || Eff W5 || Eff W6  
 
|-
 
|-
|'''4146'''|| 5/29/13 || 1500|| -750|| 550 || 0.908906 || 0.393795 || 0.384205 || 0.381543 || 0.389962 || 0.907959
+
|'''4146'''|| 5/29/13 || 1500|| -750|| 550 || 0.995195 || 0.994042 || 0.993335 || 0.992137 || 0.993069 || 0.996362
 
|-
 
|-
|'''4155'''|| 6/17/13 || 1250||-625||458 || 0.00564562 || 0.000163357 || 0.000111083 || 0.000143754 || 0.000192761 || 0.00574363
+
|'''4155'''|| 6/17/13 || 1250||-625||458 || 0.909917 || 0.826014 || 0.818991 || 0.817118 || 0.934067 || 0.891657
 
|-
 
|-
|'''4157'''|| 6/21/13 || 1300|| -650|| 473 ||
+
|'''4157'''|| 6/21/13 || 1300 || -650 || 473 || 0.345951 || 0.174296 || 0.163732 || 0.15669 || 0.171655 || 0.34243
 
|-
 
|-
|4158|| 6/24/13 || 58 mv Threshold, S:F:G=1400:-700:509 ,  run started at 14:04:11 on 6/24/13, ended at 11:05  on 6/25/13. Error message at 15:38:48 on 6/25/13 said ER was not responding it seemed to recover but event number -vs- TDC had gaps for TDC ch 8-> 15, it looks like all the events came out in TDC ch 11 after the ER client recovered?, starting a new run
+
|4158|| 6/24/13 || 1400 || 509 || -700 || 0.380383 || 0.165072 || 0.174641 || 0.160287 || 0.165072 || 0.361244
 
|-
 
|-
 
|4159|| 6/25/13 || 58 mv Threshold, S:F:G=1400:-700:509 ,  run started at 11:06:05 on 6/25/13, ended at  11:12:55 on 6/26/13. ROC
 
|4159|| 6/25/13 || 58 mv Threshold, S:F:G=1400:-700:509 ,  run started at 11:06:05 on 6/25/13, ended at  11:12:55 on 6/26/13. ROC

Revision as of 22:43, 13 August 2013

58 mv Threshold

Run # date Sense HV Guard HV Field HV Eff W1 Eff W2 Eff W3 Eff W4 Eff W5 Eff W6
4146 5/29/13 1500 -750 550 0.995195 0.994042 0.993335 0.992137 0.993069 0.996362
4155 6/17/13 1250 -625 458 0.909917 0.826014 0.818991 0.817118 0.934067 0.891657
4157 6/21/13 1300 -650 473 0.345951 0.174296 0.163732 0.15669 0.171655 0.34243
4158 6/24/13 1400 509 -700 0.380383 0.165072 0.174641 0.160287 0.165072 0.361244
4159 6/25/13 58 mv Threshold, S:F:G=1400:-700:509 , run started at 11:06:05 on 6/25/13, ended at 11:12:55 on 6/26/13. ROC
4160 6/26/13 58 mv Threshold, S:F:G=1400:-700:509 , run started at 13:26:51 on 6/26/13, ER failed
4161 6/26/13 58 mv Threshold, S:F:G=1400:-700:509 , run started at 21:13:27 on 6/26/13, ended at 09:16:32 on 6/27/13, TDC40->TDC43 have events that are way out of time, restart run
4162 6/27/13 58 mv Threshold, S:F:G=1400:-700:509 , run started at 09:17:02 on 6/27/13, ended at on TDC40->TDC43 still have events that are way out of time, APlatform:ERROR Lost connection to the container = daq2.physics.isu.edu_admin. 15:39:54 06/24
4163 6/27/13 58 mv Threshold, S:F:G=1400:-700:509 , run started at 09:17:02 on 6/27/13, ended at on
4165 7/3/13 58 mv Threshold, S:F:G=1400:-700:509 , ADB cards were swapped to see if the out of time events in TDC ch 40->43 move to the channels in the other ADC, they did not, switch the cables back and check the ADC cables.
4166 7/5/13 58 mv Threshold, S:F:G=1400:-700:509 , swapped the ADB output cables such that ADB outputs in TDC chan 32->47 are now going into TDC channels 81->96. The problems with ut of time hits moved with the ADC output cables. The question now; Is it the cable, the connectors, or the TDC?