Difference between revisions of "PAA Meetings"

From New IAC Wiki
Jump to navigation Jump to search
Line 126: Line 126:
  
 
50 micrograms of gold irradiated for 30 minutes at 40 MeV had a count rate of about 1 Hz.
 
50 micrograms of gold irradiated for 30 minutes at 40 MeV had a count rate of about 1 Hz.
 +
 +
=6/26/2013=
 +
 +
 +
;Agenda
 +
:Status of coincidence counting apparatus
 +
:New collaborator (Brian Fairchild)
 +
:Proposals
 +
::[http://www.nsf.gov/funding/pgm_summ.jsp?pims_id=503223 DNDO-NSF ARI] 
 +
 +
  
 
[[Photon_Activation_Analysis_Wiki]]
 
[[Photon_Activation_Analysis_Wiki]]

Revision as of 17:59, 25 June 2013

5/1/2013

Location: IAC conference room , 3pm

Agenda
Group Mission
Charter

5/8/2013

Agenda
Current Project Summary
Potential Proposals
Improving PAA at the IAC
ice core analysis (look for volcanic ash)
coffee sample analysis


Current Projects

1.) Silver coin project.

Preliminary data exist (three coins irradiated on April 23rd, counted on April 24th, but pretty much the only thing I can see are silver and gold lines), but more analysis is needed. Also, attached is a paper on NAA on silver coins. Eric Ivie is the contact for Deep Blue Marine.

2.) IGEM PAA on gold-bearing ores project.

Proposal is submitted and pending. We should hear about it next week. Maybe Jon Stoner can give more info on it. Student: Sultan

3.)Fossils project.

Fossils obtained from SDSM&T were irradiated and counted in February. Spectra are analyzed, and there is a match between a fossil and a corresponding matrix. Report is written. No proposal, however I think we should proceed with it and contact Darrin Cognac, who provided samples. Doug is interested in this too.

Potential Proposals

1.) Silver Coin Proposal is written, almost finished, but no budget yet.

2.) A proposal to analyze fossils provided by Darrin Cognac at S. Dakota School of Mines and Technology(http://www.sdsmt.edu). Preliminary results have shown promise (see above) in using PAA to associate a fossil with a matrix. Doug is interested in this too.

3.)http://www.nsf.gov/funding/pgm_summ.jsp?pims_id=6186

"2) Development of New Instrumentation, Analytical Techniques or Software that will extend current research and research training capabilities in the Earth sciences. The maximum request is $1,000,000;"

5/15/2013

4pm IAC conference room

Agenda
Software
Improving PAA at the IAC (coincidence counting)
Proposal writing
ice core analysis (look for volcanic ash)
coffee sample analysis


1.) Will write proposal for Deep Blue Marine

2.) Fossil proposal is in search of an RFP, work with Doug and company. Phil may be interested in working on it.

3.)NSF-MRI in


5/29/2013

4pm IAC conference room

Agenda
Status of coincidence counting apparatus
Proposals
ProposalDeepBlueMarine_2013
DTRA
ISO-17025 Accreditation (International Organization for Standardization)
http://en.wikipedia.org/wiki/ISO/IEC_17025
Run Plan for Gold activation experiment

Status of Coincidence Counting

  • Two HpGe are working
  • A third HpGe detector needs software to drive the HV. Will test it Monday. If it works we will need a Dewar plug
  • 180-2 is an HpGe detector needed neg HV and producing negative output pulses, output 2 has a < 10 usec output while output 1 has a > 10 usec outpu
  • 180-3 is takes positive HV and outputs positive pulses, both of its output appear to be the same > 10 usec pulse
  • CFDs are in place for both detectors (a third CFD channel is available in case a third HpGe detector comes online).
  • A coincidence circuit is available in case we want to have a coincidence trigger
  • The smallest capacitor Dewar is refilled every other day(if running on the weekend someone will need to come in on Sunday)
  • Next Steps
    • invert pulses so they are Negative and measureable by the CAEN V792 ADC
    • install level translator to translate CFD pulses to ECL pulses that will go to TDC
    • install DAQ1 at the IAC (perhaps near the end of next week)
    • begin commissioning of DAQ (energy calibration, efficiency, acceptance, deadtime,...)
    • install NaI detector (need -HV PS and another CFD channel)


6/12/2013

Agenda
Status of coincidence counting apparatus
New collaborator (Brian Fairchild)
Proposals
ProposalDeepBlueMarine_2013
Gold mining PAA

Status of Coincidence Counting

  • Three HpGe are working (need to measure a source to determine energy resolution)
  • DAQ computer is set up
  • coincidences were observed using irradiated Gold-sand samples (1 -> 100 Hz)
Next steps
setup gates for ADC integration of Detector pulse
CFDs used for TDC, leading edge for ADC
The CFD logic pulse is 3 microseconds after leading edge pulse
Clear TDC after ADC based logic says there is a signal

Gold Activation

Used Jack on June4-5 to irradiate 5 crucibles containing sand and 50 micrograms of gold One blank, 4 had gold

Used same irradiation time (30 minutes)

Used pickup loop to measure peak current

A magnet Dipole was used to measure energy FWHM > 1 MeV.


50 micrograms of gold irradiated for 30 minutes at 40 MeV had a count rate of about 1 Hz.

6/26/2013

Agenda
Status of coincidence counting apparatus
New collaborator (Brian Fairchild)
Proposals
DNDO-NSF ARI


Photon_Activation_Analysis_Wiki